[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-KSN":3},{"classification":4,"mappedDevices":39,"similarCandidates":40,"relatedClassifications":114,"syncDates":115,"translation":122,"marketSummary":128,"recalls":143,"k510s":145,"pmas":152},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":10,"medical_specialty_description":11,"review_panel":10,"submission_type_id":12,"definition":13,"implant_flag":14,"life_sustain_support_flag":14,"gmp_exempt_flag":14,"raw":15,"created_at":33,"updated_at":34,"recall_count":35,"latest_recall_date":36,"k510_count":37,"pma_count":35,"event_count":38},116,"KSN","Centrifuge, Cell-Washing, Automated For Immuno-Hematology","2","864.9285","HE","Hematology","1","",false,{"openfda":16,"definition":13,"device_name":7,"review_code":13,"device_class":8,"implant_flag":31,"product_code":6,"review_panel":10,"gmp_exempt_flag":31,"third_party_flag":31,"medical_specialty":10,"regulation_number":9,"submission_type_id":12,"unclassified_reason":13,"life_sustain_support_flag":31,"medical_specialty_description":11,"summary_malfunction_reporting":32},{"k_number":17,"fei_number":19,"registration_number":28},[18],"K790767",[20,21,22,23,24,25,26,27],"3012963943","3004086278","1000136573","3002642396","3000308930","2250051","3004973569","1000086912",[20,21,29,23,24,25,26,30],"1319681","3000236920","N","Eligible","2026-08-18T05:52:47.660896+00:00","2026-08-24T02:00:48.882786+00:00",0,null,1,3,[],[41,49,56,63,71,78,86,93,100,107],{"medical_device_id":42,"generic_name":43,"class_classification":44,"jmdn_code":45,"name_similarity":46,"definition_similarity":35,"vector_similarity":47,"score":48},3561,"セル洗浄遠心機","Ⅰ","35901000",0.415094,0.764584,0.0327869,{"medical_device_id":50,"generic_name":51,"class_classification":44,"jmdn_code":52,"name_similarity":53,"definition_similarity":35,"vector_similarity":54,"score":55},3560,"細胞用遠心機","35881000",0.285714,0.694793,0.031746,{"medical_device_id":57,"generic_name":58,"class_classification":44,"jmdn_code":59,"name_similarity":60,"definition_similarity":35,"vector_similarity":61,"score":62},3557,"ヘマトクリット用遠心機","32429000",0.293103,0.689233,0.0308349,{"medical_device_id":64,"generic_name":65,"class_classification":66,"jmdn_code":67,"name_similarity":68,"definition_similarity":35,"vector_similarity":69,"score":70},746,"自己血球洗浄セット","Ⅲ","17605000",0.171053,0.688023,0.0274798,{"medical_device_id":72,"generic_name":73,"class_classification":44,"jmdn_code":74,"name_similarity":75,"definition_similarity":35,"vector_similarity":76,"score":77},3582,"自動細胞診装置","70190000",0.184211,0.665251,0.0273133,{"medical_device_id":79,"generic_name":80,"class_classification":81,"jmdn_code":82,"name_similarity":83,"definition_similarity":35,"vector_similarity":84,"score":85},2393,"遠心型血液成分分離装置用血液回路","Ⅱ","70555000",0.197531,0.648755,0.0270125,{"medical_device_id":87,"generic_name":88,"class_classification":44,"jmdn_code":89,"name_similarity":90,"definition_similarity":35,"vector_similarity":91,"score":92},3541,"血液像自動分析装置","35479000",0.158537,0.690711,0.0269736,{"medical_device_id":94,"generic_name":95,"class_classification":44,"jmdn_code":96,"name_similarity":97,"definition_similarity":35,"vector_similarity":98,"score":99},3588,"自動染色装置","70191000",0.179104,0.660105,0.0267427,{"medical_device_id":101,"generic_name":102,"class_classification":44,"jmdn_code":103,"name_similarity":104,"definition_similarity":35,"vector_similarity":105,"score":106},3569,"血液型分析装置","35635000",0.155844,0.683002,0.0260504,{"medical_device_id":108,"generic_name":109,"class_classification":44,"jmdn_code":110,"name_similarity":111,"definition_similarity":35,"vector_similarity":112,"score":113},3558,"供血用遠心機","15115000",0.174603,0.652904,0.0257468,[],{"510k":116,"classification":117,"enforcement":118,"event":119,"pma":120,"warning_letter":121},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":123,"definition_ja":36,"commentary_ja":124,"model_name":125,"source_hash":126,"reviewed_by":36,"reviewed_at":36,"created_at":127,"updated_at":127},"免疫血液学用自動細胞洗浄遠心機","この機器は、免疫血液学検査において血球細胞を自動的に洗浄する遠心機です。米国ではクラスIIに分類されており、市販前届出（510(k)）による審査を経て、既存の同等製品との実質的同等性が確認されることで市販が認められます。","claude-sonnet-5","d08d2f5d03b434f7b67ef878086b6d3d35f5362205132b294f048fff73094f5c","2026-08-24T02:08:40.973135+00:00",{"product_code":6,"summary_ja":129,"stats":130,"stats_hash":141,"model_name":125,"created_at":142,"updated_at":142},"本製品コードにおける510(k)の累計件数は1件、参入企業数は1社にとどまり、直近5年間の届出はありません。不具合報告の累計件数は3件で、内訳は不具合（Malfunction）が2件、その他が1件であり、死亡・傷害の報告は確認されていません。回収については累計件数0件であり、クラスI・II・IIIいずれの区分でも報告は確認されていません。",{"pma":131,"k510":132,"as_of":134,"events":135,"recalls":138,"top_problems":140},{"latest":36,"originals":35,"supplements":35},{"total":37,"last5y":35,"latest":133,"applicants":37},"1979-05-23","2026-08",{"death":35,"other":37,"total":38,"injury":35,"last5y":35,"malfunction":136,"latest_month":137},2,"2012-09",{"total":35,"last5y":35,"latest":36,"class_i":35,"class_ii":35,"class_iii":35,"top_root_causes":139},[],[],"12d8d380872d128a04c621b03f752cd9b366c95d02be5f3cea275a3e47d11138","2026-08-24T04:46:30.426153+00:00",{"items":144,"total":35},[],{"items":146,"total":37},[147],{"k_number":18,"device_name":148,"applicant":149,"decision_date":133,"clearance_type":150,"decision_code":151,"statement_or_summary":36},"IMMU-TEK AUTOMATIC CENTRIFUGE","Dade, Baxter Travenol Diagnostics, Inc.","Traditional","SESE",{"items":153,"total":35},[]]