[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-LWA":3},{"classification":4,"mappedDevices":28,"similarCandidates":29,"relatedClassifications":99,"syncDates":100,"translation":107,"marketSummary":113,"recalls":130,"k510s":132,"pmas":134},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":9,"medical_specialty_description":10,"review_panel":11,"submission_type_id":12,"definition":9,"implant_flag":13,"life_sustain_support_flag":14,"gmp_exempt_flag":14,"raw":15,"created_at":22,"updated_at":23,"recall_count":24,"latest_recall_date":25,"k510_count":24,"pma_count":26,"event_count":27},1666,"LWA","Prosthesis, Ligament, Ptfe","3","","Unknown","OR","2",true,false,{"openfda":16,"definition":9,"device_name":7,"review_code":9,"device_class":8,"implant_flag":19,"product_code":6,"review_panel":11,"gmp_exempt_flag":20,"third_party_flag":20,"medical_specialty":9,"regulation_number":9,"submission_type_id":12,"unclassified_reason":9,"life_sustain_support_flag":20,"medical_specialty_description":10,"summary_malfunction_reporting":21},{"pma_number":17},[18],"P850074","Y","N","Eligible","2026-08-18T05:52:49.347546+00:00","2026-08-24T02:00:48.225237+00:00",0,null,5,2,[],[30,38,46,53,60,67,73,80,86,93],{"medical_device_id":31,"generic_name":32,"class_classification":33,"jmdn_code":34,"name_similarity":35,"definition_similarity":24,"vector_similarity":36,"score":37},171,"吸収性人工靭帯","Ⅳ","35717004",0.571429,0.782254,0.0327869,{"medical_device_id":39,"generic_name":40,"class_classification":41,"jmdn_code":42,"name_similarity":43,"definition_similarity":24,"vector_similarity":44,"score":45},515,"非吸収性人工靭帯","Ⅲ","35717003",0.512821,0.767287,0.0322581,{"medical_device_id":47,"generic_name":48,"class_classification":41,"jmdn_code":49,"name_similarity":50,"definition_similarity":24,"vector_similarity":51,"score":52},674,"筋肉用補綴材","35272000",0.354839,0.69858,0.0273973,{"medical_device_id":54,"generic_name":55,"class_classification":41,"jmdn_code":56,"name_similarity":57,"definition_similarity":24,"vector_similarity":58,"score":59},565,"人工骨頭","33704000",0.34375,0.67811,0.0244444,{"medical_device_id":61,"generic_name":62,"class_classification":41,"jmdn_code":63,"name_similarity":64,"definition_similarity":24,"vector_similarity":65,"score":66},684,"ロッド型人工陰茎","36251000",0.323529,0.680389,0.0236894,{"medical_device_id":68,"generic_name":69,"class_classification":41,"jmdn_code":70,"name_similarity":64,"definition_similarity":24,"vector_similarity":71,"score":72},687,"眼弁補綴材","42526000",0.682806,0.0235327,{"medical_device_id":74,"generic_name":75,"class_classification":41,"jmdn_code":76,"name_similarity":77,"definition_similarity":24,"vector_similarity":78,"score":79},572,"全人工膝関節","35667000",0.314286,0.68544,0.0231407,{"medical_device_id":81,"generic_name":82,"class_classification":41,"jmdn_code":83,"name_similarity":77,"definition_similarity":24,"vector_similarity":84,"score":85},591,"人工椎間板","34163000",0.679079,0.0228639,{"medical_device_id":87,"generic_name":88,"class_classification":41,"jmdn_code":89,"name_similarity":90,"definition_similarity":24,"vector_similarity":91,"score":92},661,"体内用合成・炭素繊維補綴材","33473103",0.189655,0.757654,0.015873,{"medical_device_id":94,"generic_name":95,"class_classification":41,"jmdn_code":96,"name_similarity":97,"definition_similarity":24,"vector_similarity":98,"score":92},673,"喉頭用補綴材","35268000",0.4,0.660495,[],{"510k":101,"classification":102,"enforcement":103,"event":104,"pma":105,"warning_letter":106},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":108,"definition_ja":25,"commentary_ja":109,"model_name":110,"source_hash":111,"reviewed_by":25,"reviewed_at":25,"created_at":112,"updated_at":112},"PTFE製人工靱帯","この機器はポリテトラフルオロエチレン（PTFE）を材料とした人工靱帯であり、靱帯の代替・補強を目的として体内に埋め込まれる医療機器です。米国ではクラスIIIに分類されており、この分類は人体への潜在的リスクが高い機器に適用されるため、市販に先立って市販前承認（PMA）による厳格な審査を経る必要があります。","claude-sonnet-5","4fbc088d7c57a77861a3335b7fc8454f8207e644ec828901fa862e15a67e81f5","2026-08-24T02:13:33.96397+00:00",{"product_code":6,"summary_ja":114,"stats":115,"stats_hash":128,"model_name":110,"created_at":129,"updated_at":129},"本製品はPMA区分で、一部変更承認が累計5件あり、直近の判定は1993年3月となっています。不具合報告は累計約2件で、死亡は0件、傷害が2件と傷害中心の内訳となっており、直近5年では約1件、最新の報告は2024年7月で、主な問題として「石灰化（Calcified）」や「材質が硬すぎる・剛性が高すぎる（Material Too Rigid or Stiff）」が挙げられています。回収については累計0件で、クラスI・II・IIIいずれも報告は確認されていません。",{"pma":116,"k510":118,"as_of":119,"events":120,"recalls":123,"top_problems":125},{"latest":117,"originals":24,"supplements":26},"1993-03-03",{"total":24,"last5y":24,"latest":25,"applicants":24},"2026-08",{"death":24,"other":24,"total":27,"injury":27,"last5y":121,"malfunction":24,"latest_month":122},1,"2024-07",{"total":24,"last5y":24,"latest":25,"class_i":24,"class_ii":24,"class_iii":24,"top_root_causes":124},[],[126,127],"Calcified","Material Too Rigid or Stiff","bd33fac24e4468bca53eb6d4740bb2e52d5e88cd1e7da9072e5427fd1bc63ddf","2026-08-24T04:52:46.442187+00:00",{"items":131,"total":24},[],{"items":133,"total":24},[],{"items":135,"total":26},[136,140,143,146,149],{"pma_number":18,"supplement_number":137,"trade_name":138,"applicant":139,"decision_date":117},"S008","GORE-TEX{TM} CRUCIATE LIGAMENT PROSTHESIS","W. L. Gore & Associates, Inc.",{"pma_number":18,"supplement_number":141,"trade_name":138,"applicant":139,"decision_date":142},"S006","1989-08-03",{"pma_number":18,"supplement_number":144,"trade_name":138,"applicant":139,"decision_date":145},"S004","1988-12-12",{"pma_number":18,"supplement_number":147,"trade_name":138,"applicant":139,"decision_date":148},"S003","1987-06-30",{"pma_number":18,"supplement_number":150,"trade_name":151,"applicant":139,"decision_date":152},"S001","GORE-TEX EXPANDED PTFE PROSTHETIC LIGAMENT","1987-01-16"]