[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-MWG":3},{"classification":4,"mappedDevices":31,"similarCandidates":32,"relatedClassifications":104,"syncDates":105,"translation":112,"marketSummary":118,"recalls":139,"k510s":141,"pmas":143},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":9,"medical_specialty_description":10,"review_panel":11,"submission_type_id":12,"definition":9,"implant_flag":13,"life_sustain_support_flag":13,"gmp_exempt_flag":13,"raw":14,"created_at":25,"updated_at":26,"recall_count":27,"latest_recall_date":28,"k510_count":27,"pma_count":29,"event_count":30},627,"MWG","System, Oxygen, Aqueous","3","","Unknown","CV","2",false,{"openfda":15,"definition":9,"device_name":7,"review_code":9,"device_class":8,"implant_flag":23,"product_code":6,"review_panel":11,"gmp_exempt_flag":23,"third_party_flag":23,"medical_specialty":9,"regulation_number":9,"submission_type_id":12,"unclassified_reason":9,"life_sustain_support_flag":23,"medical_specialty_description":10,"summary_malfunction_reporting":24},{"fei_number":16,"pma_number":19,"registration_number":21},[17,18],"3029871637","3003793491",[20],"P170027",[17,22],"3010617000","N","Ineligible","2026-08-18T05:52:48.222586+00:00","2026-08-24T02:00:47.949024+00:00",0,null,21,13,[],[33,41,48,56,64,71,77,83,90,97],{"medical_device_id":34,"generic_name":35,"class_classification":36,"jmdn_code":37,"name_similarity":38,"definition_similarity":27,"vector_similarity":39,"score":40},807,"酸素治療送入システム","Ⅲ","37498000",0.358974,0.720988,0.0327869,{"medical_device_id":42,"generic_name":43,"class_classification":36,"jmdn_code":44,"name_similarity":45,"definition_similarity":27,"vector_similarity":46,"score":47},788,"麻酔システム","37710000",0.242424,0.718723,0.0315136,{"medical_device_id":49,"generic_name":50,"class_classification":51,"jmdn_code":52,"name_similarity":53,"definition_similarity":27,"vector_similarity":54,"score":55},3936,"酸素ガス分析装置","Ⅰ","35219000",0.235294,0.680039,0.030303,{"medical_device_id":57,"generic_name":58,"class_classification":59,"jmdn_code":60,"name_similarity":61,"definition_similarity":27,"vector_similarity":62,"score":63},2446,"酸素コントローラ","Ⅱ","70577000",0.212121,0.690753,0.0299575,{"medical_device_id":65,"generic_name":66,"class_classification":59,"jmdn_code":67,"name_similarity":68,"definition_similarity":27,"vector_similarity":69,"score":70},2450,"酸素濃縮装置","12873002",0.2,0.682291,0.0283716,{"medical_device_id":72,"generic_name":73,"class_classification":51,"jmdn_code":74,"name_similarity":68,"definition_similarity":27,"vector_similarity":75,"score":76},3528,"血液ガス酸素分析装置","12590000",0.668401,0.0272222,{"medical_device_id":78,"generic_name":79,"class_classification":51,"jmdn_code":80,"name_similarity":53,"definition_similarity":27,"vector_similarity":81,"score":82},3937,"空気・酸素混合装置","70578000",0.649154,0.0268301,{"medical_device_id":84,"generic_name":85,"class_classification":36,"jmdn_code":86,"name_similarity":87,"definition_similarity":27,"vector_similarity":88,"score":89},806,"一酸化窒素ガス管理システム","37266000",0.196078,0.649204,0.0243939,{"medical_device_id":91,"generic_name":92,"class_classification":36,"jmdn_code":93,"name_similarity":94,"definition_similarity":27,"vector_similarity":95,"score":96},753,"血液濾過用装置","35453000",0.189189,0.655858,0.0241525,{"medical_device_id":98,"generic_name":99,"class_classification":59,"jmdn_code":100,"name_similarity":101,"definition_similarity":27,"vector_similarity":102,"score":103},2440,"空気・酸素マスク","35171000",0.266667,0.604508,0.016129,[],{"510k":106,"classification":107,"enforcement":108,"event":109,"pma":110,"warning_letter":111},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":113,"definition_ja":28,"commentary_ja":114,"model_name":115,"source_hash":116,"reviewed_by":28,"reviewed_at":28,"created_at":117,"updated_at":117},"水系酸素供給システム","本機器は米国FDAの分類においてクラスIIIに区分されており、市販前承認（PMA）による審査が求められます。クラスIIIはFDAの分類制度の中で最も規制が厳格な区分であり、人の生命維持や健康に重大な影響を及ぼす可能性がある機器、または有効性・安全性を示す十分な情報が確立していない機器が該当し、市販前届出（510(k)）ではなく、より詳細な科学的根拠の提出を伴うPMAの取得が必要となります。","claude-sonnet-5","26f0eeb4ea5c4de36b48926772369f92b15a5cb5e52683dbb75e8764815adbd2","2026-08-24T02:15:50.744711+00:00",{"product_code":6,"summary_ja":119,"stats":120,"stats_hash":137,"model_name":115,"created_at":138,"updated_at":138},"本製品はPMA（市販前承認）区分で、本承認が1件、一部変更承認が約20件あり、最新の判定は2026年4月となっています。不具合報告は累計約13件で、死亡1件、傷害が約10件と大半を占め、不具合（Malfunction）は約2件にとどまっており、主な問題としてFluid\u002FBlood Leak（体液・血液の漏れ）、Material Integrity Problem（材質の完全性の問題）、Material Puncture\u002FHole（材質の穿孔・穴）が挙げられています。回収については累計・直近5年ともに件数は確認されていません。",{"pma":121,"k510":125,"as_of":126,"events":127,"recalls":131,"top_problems":133},{"latest":122,"originals":123,"supplements":124},"2026-04-10",1,20,{"total":27,"last5y":27,"latest":28,"applicants":27},"2026-08",{"death":123,"other":27,"total":30,"injury":128,"last5y":30,"malfunction":129,"latest_month":130},10,2,"2026-02",{"total":27,"last5y":27,"latest":28,"class_i":27,"class_ii":27,"class_iii":27,"top_root_causes":132},[],[134,135,136],"Fluid\u002FBlood Leak","Material Integrity Problem","Material Puncture\u002FHole","dc9bd6cbe08622526fa69f266077bb17faca047ce2e8971dc9c0b3b4c00d033b","2026-08-24T04:57:04.90455+00:00",{"items":140,"total":27},[],{"items":142,"total":27},[],{"items":144,"total":29},[145,149,152,156,159,163,166,169,173,175,178,181,184,188,191,194,197,200,203,206],{"pma_number":20,"supplement_number":146,"trade_name":147,"applicant":148,"decision_date":122},"S018","TherOx Downstream System","Zoll Circulation, Inc.",{"pma_number":20,"supplement_number":150,"trade_name":147,"applicant":148,"decision_date":151},"S020","2025-10-29",{"pma_number":20,"supplement_number":153,"trade_name":154,"applicant":148,"decision_date":155},"S019","TherOx Downstream Cartridge","2025-06-20",{"pma_number":20,"supplement_number":157,"trade_name":147,"applicant":148,"decision_date":158},"S017","2024-12-19",{"pma_number":20,"supplement_number":160,"trade_name":161,"applicant":148,"decision_date":162},"S016","TherOx DownStream System","2024-12-11",{"pma_number":20,"supplement_number":164,"trade_name":147,"applicant":148,"decision_date":165},"S014","2024-10-03",{"pma_number":20,"supplement_number":167,"trade_name":161,"applicant":148,"decision_date":168},"S015","2024-08-14",{"pma_number":20,"supplement_number":170,"trade_name":171,"applicant":148,"decision_date":172},"S012","TherOx® DownStream® Cartridge (DSC-2)","2024-06-06",{"pma_number":20,"supplement_number":174,"trade_name":147,"applicant":148,"decision_date":172},"S011",{"pma_number":20,"supplement_number":176,"trade_name":147,"applicant":148,"decision_date":177},"S013","2024-04-25",{"pma_number":20,"supplement_number":179,"trade_name":147,"applicant":148,"decision_date":180},"S007","2023-10-20",{"pma_number":20,"supplement_number":182,"trade_name":147,"applicant":148,"decision_date":183},"S008","2023-03-09",{"pma_number":20,"supplement_number":185,"trade_name":186,"applicant":148,"decision_date":187},"S010","TherOx Downstream Console","2022-10-27",{"pma_number":20,"supplement_number":189,"trade_name":147,"applicant":148,"decision_date":190},"S009","2022-03-10",{"pma_number":20,"supplement_number":192,"trade_name":161,"applicant":148,"decision_date":193},"S006","2021-12-09",{"pma_number":20,"supplement_number":195,"trade_name":147,"applicant":148,"decision_date":196},"S005","2021-06-01",{"pma_number":20,"supplement_number":198,"trade_name":147,"applicant":148,"decision_date":199},"S004","2021-03-29",{"pma_number":20,"supplement_number":201,"trade_name":147,"applicant":148,"decision_date":202},"S003","2021-03-26",{"pma_number":20,"supplement_number":204,"trade_name":161,"applicant":148,"decision_date":205},"S001","2020-11-20",{"pma_number":20,"supplement_number":207,"trade_name":147,"applicant":148,"decision_date":208},"S002","2020-03-11"]