[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-NAM":3},{"classification":4,"mappedDevices":45,"similarCandidates":46,"relatedClassifications":121,"syncDates":122,"translation":129,"marketSummary":135,"recalls":157,"k510s":159,"pmas":195},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":10,"medical_specialty_description":11,"review_panel":10,"submission_type_id":12,"definition":13,"implant_flag":14,"life_sustain_support_flag":14,"gmp_exempt_flag":14,"raw":15,"created_at":39,"updated_at":40,"recall_count":41,"latest_recall_date":42,"k510_count":43,"pma_count":41,"event_count":44},5323,"NAM","Stimulator, Peripheral Nerve, Non-Implanted, For Urinary Incontinence","2","876.5310","GU","Gastroenterology, Urology","1","",false,{"openfda":16,"definition":13,"device_name":7,"review_code":13,"device_class":8,"implant_flag":37,"product_code":6,"review_panel":10,"gmp_exempt_flag":37,"third_party_flag":37,"medical_specialty":10,"regulation_number":9,"submission_type_id":12,"unclassified_reason":13,"life_sustain_support_flag":37,"medical_specialty_description":11,"summary_malfunction_reporting":38},{"k_number":17,"fei_number":26,"registration_number":35},[18,19,20,21,22,23,24,25],"K071822","K192731","K061333","K220454","DEN000002","K052025","K132561","K101847",[27,28,29,30,31,32,33,34],"1000116809","2183613","3002647932","3021071765","3003477135","3027578962","2182207","3018094310",[28,29,30,31,32,33,34,36],"2183164","N","Eligible","2026-08-18T05:52:52.566809+00:00","2026-08-24T02:00:47.513022+00:00",0,null,8,92,[],[47,55,63,71,78,85,92,99,107,114],{"medical_device_id":48,"generic_name":49,"class_classification":50,"jmdn_code":51,"name_similarity":52,"definition_similarity":41,"vector_similarity":53,"score":54},2999,"尿失禁治療用磁気刺激装置","Ⅱ","71035002",0.421687,0.816501,0.0320184,{"medical_device_id":56,"generic_name":57,"class_classification":58,"jmdn_code":59,"name_similarity":60,"definition_similarity":41,"vector_similarity":61,"score":62},302,"植込み型失禁用神経筋電気刺激装置","Ⅳ","36175000",0.366667,0.848743,0.032002,{"medical_device_id":64,"generic_name":65,"class_classification":66,"jmdn_code":67,"name_similarity":68,"definition_similarity":41,"vector_similarity":69,"score":70},838,"失禁用神経筋電気刺激装置","Ⅲ","36784000",0.317647,0.853655,0.0313188,{"medical_device_id":72,"generic_name":73,"class_classification":58,"jmdn_code":74,"name_similarity":75,"definition_similarity":41,"vector_similarity":76,"score":77},321,"植込み型末梢神経無痛法用電気刺激装置","38474000",0.393258,0.778682,0.0312805,{"medical_device_id":79,"generic_name":80,"class_classification":66,"jmdn_code":81,"name_similarity":82,"definition_similarity":41,"vector_similarity":83,"score":84},652,"植込み型失禁用刺激電極及びリード","44045000",0.357143,0.760596,0.0305504,{"medical_device_id":86,"generic_name":87,"class_classification":50,"jmdn_code":88,"name_similarity":89,"definition_similarity":41,"vector_similarity":90,"score":91},1491,"ブロックモニタ用末梢神経電気刺激装置","35722000",0.325843,0.746255,0.0296703,{"medical_device_id":93,"generic_name":94,"class_classification":50,"jmdn_code":95,"name_similarity":96,"definition_similarity":41,"vector_similarity":97,"score":98},2244,"尿失禁防止用具","70431000",0.283951,0.740463,0.0285773,{"medical_device_id":100,"generic_name":101,"class_classification":102,"jmdn_code":103,"name_similarity":104,"definition_similarity":41,"vector_similarity":105,"score":106},3793,"尿失禁挙上針","Ⅰ","70430001",0.32,0.716897,0.0271997,{"medical_device_id":108,"generic_name":109,"class_classification":58,"jmdn_code":110,"name_similarity":111,"definition_similarity":41,"vector_similarity":112,"score":113},304,"植込み型排尿・排便機能制御用スティミュレータ","70599000",0.214286,0.833825,0.0269841,{"medical_device_id":115,"generic_name":116,"class_classification":66,"jmdn_code":117,"name_similarity":118,"definition_similarity":41,"vector_similarity":119,"score":120},665,"体内用失禁補綴材","34214100",0.253165,0.739859,0.0268759,[],{"510k":123,"classification":124,"enforcement":125,"event":126,"pma":127,"warning_letter":128},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":130,"definition_ja":42,"commentary_ja":131,"model_name":132,"source_hash":133,"reviewed_by":42,"reviewed_at":42,"created_at":134,"updated_at":134},"非植込み型末梢神経刺激装置（尿失禁治療用）","本品は、尿失禁の治療を目的として末梢神経に刺激を与える、体内に植え込まないタイプの神経刺激装置です。米国ではクラスIIに分類されており、市販前届出（510(k)）により、既存の同等品との実質的同等性を示すことで市販が認められる規制区分となっています。","claude-sonnet-5","0229860d34402cc5b295e33072b83246f927c4e9e7c66ceda44047c00e9a45bd","2026-08-24T02:15:50.744711+00:00",{"product_code":6,"summary_ja":136,"stats":137,"stats_hash":155,"model_name":132,"created_at":156,"updated_at":156},"本製品コードでは、510(k)（市販前届出）が累計8件、申請企業は5社で、直近5年間では1件、最新の判定は2023年4月となっています。不具合報告（MDR）は累計約90件で、その大半を傷害（Injury）が占め、不具合（Malfunction）は少数にとどまり、死亡報告は0件です。主な問題としては、装置からの異臭発生（Device Emits Odor）、不適切・不十分な電気刺激（Inappropriate\u002FInadequate Shock\u002FStimulation）、装置の位置ずれ・脱落（Migration or Expulsion of Device）が挙げられています。なお、回収（リコール）の実施は確認されていません。",{"pma":138,"k510":139,"as_of":143,"events":144,"recalls":149,"top_problems":151},{"latest":42,"originals":41,"supplements":41},{"total":43,"last5y":140,"latest":141,"applicants":142},1,"2023-04-03",5,"2026-08",{"death":41,"other":140,"total":44,"injury":145,"last5y":146,"malfunction":147,"latest_month":148},89,6,2,"2026-02",{"total":41,"last5y":41,"latest":42,"class_i":41,"class_ii":41,"class_iii":41,"top_root_causes":150},[],[152,153,154],"Device Emits Odor","Inappropriate\u002FInadequate Shock\u002FStimulation","Migration or Expulsion of Device","911adbdf35f5f21a3aa4e53c477e08087ee65c16f026f87455223d46488d1eb1","2026-08-24T04:57:04.90455+00:00",{"items":158,"total":41},[],{"items":160,"total":43},[161,167,171,175,179,182,186,189],{"k_number":21,"device_name":162,"applicant":163,"decision_date":141,"clearance_type":164,"decision_code":165,"statement_or_summary":166},"Vivally System Wearable, Non-Invasive Neuromodulation System and Mobile Application","Avation Medical, Inc.","Traditional","SESE","Summary",{"k_number":19,"device_name":168,"applicant":169,"decision_date":170,"clearance_type":164,"decision_code":165,"statement_or_summary":166},"ZIDA Wearable Neuromodulation System","Exodus Innovations","2021-03-19",{"k_number":24,"device_name":172,"applicant":173,"decision_date":174,"clearance_type":164,"decision_code":165,"statement_or_summary":166},"NURO NEUROMODULATION SYSTEM","Advanced Uro-Solutions, Inc.","2013-11-05",{"k_number":25,"device_name":176,"applicant":177,"decision_date":178,"clearance_type":164,"decision_code":165,"statement_or_summary":166},"URGENT PC STIMULATOR; URGENT PC LEAD SET","Uroplasty, Inc.","2010-10-21",{"k_number":18,"device_name":180,"applicant":177,"decision_date":181,"clearance_type":164,"decision_code":165,"statement_or_summary":166},"URGENT PC NEUROMODULATION SYSTEM, MODELS UPC200 AND UPC250-12","2007-08-20",{"k_number":20,"device_name":183,"applicant":177,"decision_date":184,"clearance_type":185,"decision_code":165,"statement_or_summary":166},"URGENT PC NEUROMODULATION SYSTEM, MODELS UPC200-A AND UPC250-12","2006-07-03","Special",{"k_number":23,"device_name":187,"applicant":177,"decision_date":188,"clearance_type":164,"decision_code":165,"statement_or_summary":166},"URGENT PC NEUROMODULATION SYSTEM","2005-10-17",{"k_number":22,"device_name":190,"applicant":191,"decision_date":192,"clearance_type":193,"decision_code":194,"statement_or_summary":42},"UROSURGE PERCUTANEOUS SANS (STOLLER AFFERENT NERVE STIMULATOR) DEVICE","Urosurge, Inc.","2000-02-09","Post-NSE","DENG",{"items":196,"total":41},[]]