[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-NAN":3},{"classification":4,"mappedDevices":25,"similarCandidates":26,"relatedClassifications":99,"syncDates":100,"translation":107,"marketSummary":113,"recalls":127,"k510s":129,"pmas":131},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":9,"medical_specialty_description":10,"review_panel":11,"submission_type_id":12,"definition":9,"implant_flag":13,"life_sustain_support_flag":13,"gmp_exempt_flag":13,"raw":14,"created_at":20,"updated_at":21,"recall_count":22,"latest_recall_date":23,"k510_count":22,"pma_count":24,"event_count":22},6654,"NAN","Tester, Acoustic, Bone Quality","3","","Unknown","RA","2",false,{"openfda":15,"definition":9,"device_name":7,"review_code":9,"device_class":8,"implant_flag":18,"product_code":6,"review_panel":11,"gmp_exempt_flag":18,"third_party_flag":18,"medical_specialty":9,"regulation_number":9,"submission_type_id":12,"unclassified_reason":9,"life_sustain_support_flag":18,"medical_specialty_description":10,"summary_malfunction_reporting":19},{"pma_number":16},[17],"P990039","N","Eligible","2026-08-18T05:52:53.686257+00:00","2026-08-24T02:00:48.366308+00:00",0,null,2,[],[27,35,43,50,57,64,71,78,85,92],{"medical_device_id":28,"generic_name":29,"class_classification":30,"jmdn_code":31,"name_similarity":32,"definition_similarity":22,"vector_similarity":33,"score":34},1601,"神経疾患診断用定量的感覚検査器","Ⅱ","37349000",0.178082,0.682722,0.0310544,{"medical_device_id":36,"generic_name":37,"class_classification":38,"jmdn_code":39,"name_similarity":40,"definition_similarity":22,"vector_similarity":41,"score":42},4449,"咀嚼能力検査用物質","Ⅰ","71093001",0.203704,0.638362,0.0298277,{"medical_device_id":44,"generic_name":45,"class_classification":30,"jmdn_code":46,"name_similarity":47,"definition_similarity":22,"vector_similarity":48,"score":49},1322,"超音波骨密度測定装置","40779000",0.155172,0.674012,0.0286935,{"medical_device_id":51,"generic_name":52,"class_classification":38,"jmdn_code":53,"name_similarity":54,"definition_similarity":22,"vector_similarity":55,"score":56},3423,"関節運動テスタ","36148000",0.162791,0.650797,0.0284045,{"medical_device_id":58,"generic_name":59,"class_classification":38,"jmdn_code":60,"name_similarity":61,"definition_similarity":22,"vector_similarity":62,"score":63},3424,"角度計","37529000",0.175,0.638714,0.0283702,{"medical_device_id":65,"generic_name":66,"class_classification":30,"jmdn_code":67,"name_similarity":68,"definition_similarity":22,"vector_similarity":69,"score":70},1282,"骨放射線吸収測定装置","38314000",0.176471,0.633449,0.0276929,{"medical_device_id":72,"generic_name":73,"class_classification":30,"jmdn_code":74,"name_similarity":75,"definition_similarity":22,"vector_similarity":76,"score":77},1620,"触覚用定量的感覚検査器","35056000",0.151515,0.658635,0.0271205,{"medical_device_id":79,"generic_name":80,"class_classification":30,"jmdn_code":81,"name_similarity":82,"definition_similarity":22,"vector_similarity":83,"score":84},3144,"神経疾患診断用定量的感覚検査器用プログラム","37349012",0.152941,0.622123,0.0248534,{"medical_device_id":86,"generic_name":87,"class_classification":38,"jmdn_code":88,"name_similarity":89,"definition_similarity":22,"vector_similarity":90,"score":91},3915,"人工弁テスタ","70482000",0.152174,0.616379,0.023736,{"medical_device_id":93,"generic_name":94,"class_classification":30,"jmdn_code":95,"name_similarity":96,"definition_similarity":22,"vector_similarity":97,"score":98},1604,"純音オージオメータ","37503000",0.136364,0.6892,0.0163934,[],{"510k":101,"classification":102,"enforcement":103,"event":104,"pma":105,"warning_letter":106},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":108,"definition_ja":23,"commentary_ja":109,"model_name":110,"source_hash":111,"reviewed_by":23,"reviewed_at":23,"created_at":112,"updated_at":112},"骨質音響測定器","この機器は、音響的手法を用いて骨の質を測定する装置です。米国ではクラスIIIに分類されており、これは人体へのリスクが最も高いとされる区分であるため、市販前承認（PMA）による厳格な科学的審査を経て有効性と安全性が確認される必要があります。","claude-sonnet-5","b744c6841406760cdb05bc80b798a10e87b260fa84be8ac33967e4290f7b665e","2026-08-24T02:15:50.744711+00:00",{"product_code":6,"summary_ja":114,"stats":115,"stats_hash":125,"model_name":110,"created_at":126,"updated_at":126},"本製品はPMA(市販前承認)区分で、本承認1件と一部変更承認1件が確認されており、最新の判定は2003年6月となっています。不具合報告および回収については、いずれも累計件数0件で、報告や回収の実績は確認されていません。",{"pma":116,"k510":119,"as_of":120,"events":121,"recalls":122,"top_problems":124},{"latest":117,"originals":118,"supplements":118},"2003-06-19",1,{"total":22,"last5y":22,"latest":23,"applicants":22},"2026-08",{"death":22,"other":22,"total":22,"injury":22,"last5y":22,"malfunction":22,"latest_month":23},{"total":22,"last5y":22,"latest":23,"class_i":22,"class_ii":22,"class_iii":22,"top_root_causes":123},[],[],"59633b42fa3179ac53431b650579ca0927128a56a79517481ac07dec0eb44ec6","2026-08-24T04:57:04.90455+00:00",{"items":128,"total":22},[],{"items":130,"total":22},[],{"items":132,"total":24},[133,137],{"pma_number":17,"supplement_number":134,"trade_name":135,"applicant":136,"decision_date":117},"S001","QUS-2 CALCANEAL ULTRASONOMETER","Quidel Corp.",{"pma_number":17,"supplement_number":9,"trade_name":138,"applicant":136,"decision_date":139},"QUS-2 (TM) CALCANEAL ULTRASONOMETER","2000-08-01"]