[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-NPU":3},{"classification":4,"mappedDevices":54,"similarCandidates":55,"relatedClassifications":140,"syncDates":141,"translation":148,"marketSummary":155,"recalls":178,"k510s":180,"pmas":182},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":9,"medical_specialty_description":10,"review_panel":11,"submission_type_id":12,"definition":13,"implant_flag":14,"life_sustain_support_flag":14,"gmp_exempt_flag":15,"raw":16,"created_at":48,"updated_at":49,"recall_count":50,"latest_recall_date":51,"k510_count":50,"pma_count":52,"event_count":53},5950,"NPU","Prosthesis, Mitral Valve, Percutaneously Delivered","3","","Unknown","CV","2","These devices are intended to replace a patient's mitral heart valve.  They are different from the classified device (heart valves) in that they are placed percutaniously and do not require open chest surgery or a cardiotomy for placement.",true,false,{"openfda":17,"definition":13,"device_name":7,"review_code":9,"device_class":8,"implant_flag":45,"product_code":6,"review_panel":11,"gmp_exempt_flag":46,"third_party_flag":46,"medical_specialty":9,"regulation_number":9,"submission_type_id":12,"unclassified_reason":9,"life_sustain_support_flag":45,"medical_specialty_description":10,"summary_malfunction_reporting":47},{"fei_number":18,"pma_number":37,"registration_number":41},[19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36],"2015691","3010432890","3007113487","3002807314","3015287573","3014918977","3017298588","3007063218","3012179728","1713910","1928237","3005334138","3009420598","3005012805","3010421104","2011171","3002807111","1721676",[38,39,40],"P240042","P140031","P250019",[42,20,19,22,23,24,21,25,26,43,27,44,29,31,32,33,34,36],"2135147","3005941719","3008500478","Y","N","Eligible","2026-08-18T05:52:52.949882+00:00","2026-08-24T02:00:47.318533+00:00",0,null,11,1908,[],[56,65,74,83,92,100,108,116,124,132],{"medical_device_id":57,"generic_name":58,"class_classification":59,"jmdn_code":60,"name_similarity":61,"definition_similarity":62,"vector_similarity":63,"score":64},1137,"経皮的僧帽弁接合不全修復システム","Ⅳ","56280004",0.294118,0.263393,0.778284,0.0320184,{"medical_device_id":66,"generic_name":67,"class_classification":68,"jmdn_code":69,"name_similarity":70,"definition_similarity":71,"vector_similarity":72,"score":73},2363,"人工弁ローテータ","Ⅱ","70483009",0.303571,0.291457,0.760457,0.032002,{"medical_device_id":75,"generic_name":76,"class_classification":77,"jmdn_code":78,"name_similarity":79,"definition_similarity":80,"vector_similarity":81,"score":82},687,"眼弁補綴材","Ⅲ","42526000",0.326923,0.203125,0.726722,0.0310993,{"medical_device_id":84,"generic_name":85,"class_classification":86,"jmdn_code":87,"name_similarity":88,"definition_similarity":89,"vector_similarity":90,"score":91},3916,"人工弁ホルダ及びハンドル","Ⅰ","70483000",0.265625,0.282297,0.757861,0.0307984,{"medical_device_id":93,"generic_name":94,"class_classification":86,"jmdn_code":95,"name_similarity":96,"definition_similarity":97,"vector_similarity":98,"score":99},3913,"人工心臓弁用サイザ","17703010",0.274194,0.275229,0.714866,0.0294372,{"medical_device_id":101,"generic_name":102,"class_classification":86,"jmdn_code":103,"name_similarity":104,"definition_similarity":105,"vector_similarity":106,"score":107},3915,"人工弁テスタ","70482000",0.309091,0.258216,0.706856,0.0292869,{"medical_device_id":109,"generic_name":110,"class_classification":59,"jmdn_code":111,"name_similarity":112,"definition_similarity":113,"vector_similarity":114,"score":115},198,"人工血管付ブタ心臓弁","35591300",0.226667,0.253906,0.728315,0.028624,{"medical_device_id":117,"generic_name":118,"class_classification":59,"jmdn_code":119,"name_similarity":120,"definition_similarity":121,"vector_similarity":122,"score":123},195,"人工血管付機械式人工心臓弁","35590020",0.246753,0.218391,0.708562,0.0277831,{"medical_device_id":125,"generic_name":126,"class_classification":59,"jmdn_code":127,"name_similarity":128,"definition_similarity":129,"vector_similarity":130,"score":131},212,"中心循環系人工血管","35281004",0.25,0.221739,0.704292,0.0269439,{"medical_device_id":133,"generic_name":134,"class_classification":86,"jmdn_code":135,"name_similarity":136,"definition_similarity":137,"vector_similarity":138,"score":139},4316,"人工装具ドライバ","32865000",0.269231,0.161871,0.696143,0.0258564,[],{"510k":142,"classification":143,"enforcement":144,"event":145,"pma":146,"warning_letter":147},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":149,"definition_ja":150,"commentary_ja":151,"model_name":152,"source_hash":153,"reviewed_by":51,"reviewed_at":51,"created_at":154,"updated_at":154},"経皮的僧帽弁補綴材","これらの機器は、患者の僧帽弁を置換することを目的とする。これらは、経皮的に留置され、留置のために開胸手術や心切開術を必要としない点において、分類済み機器（心臓弁）とは異なる。","本機器は米国においてクラスIIIに分類されており、市販前承認（PMA）による審査対象となっています。クラスIIIはFDAの分類の中で最も規制が厳格な区分であり、有効性と安全性を裏付ける臨床データを含む詳細な審査資料の提出が求められる点で、比較的簡易な市販前届出（510(k)）とは異なる審査プロセスが適用されます。","claude-sonnet-5","423b6f855aba7ee00c0a260d51d62edede27a563eaa26b10790f58ec26e7cca4","2026-08-24T02:18:13.311568+00:00",{"product_code":6,"summary_ja":156,"stats":157,"stats_hash":176,"model_name":152,"created_at":177,"updated_at":177},"本品目はPMA（市販前承認）区分で、本承認2件、一部変更承認9件が2026年8月時点で確認されており、直近まで一部変更承認の審査が行われています。不具合報告は累計約1,900件で、死亡411件、傷害約1,400件と死亡・傷害の比率が高く、不具合（Malfunction）は約140件にとどまっています。主な問題としてはPerivalvular Leak（弁周囲逆流）、Malposition of Device（デバイスの位置異常）、Fluid\u002FBlood Leak（液体・血液の漏れ）が挙げられています。回収については累計0件で、クラスI〜IIIいずれの重篤度区分でも報告は確認されていません。",{"pma":158,"k510":162,"as_of":163,"events":164,"recalls":170,"top_problems":172},{"latest":159,"originals":160,"supplements":161},"2026-08-07",2,9,{"total":50,"last5y":50,"latest":51,"applicants":50},"2026-08",{"death":165,"other":50,"total":53,"injury":166,"last5y":167,"malfunction":168,"latest_month":169},411,1359,1467,138,"2026-07",{"total":50,"last5y":50,"latest":51,"class_i":50,"class_ii":50,"class_iii":50,"top_root_causes":171},[],[173,174,175],"Perivalvular Leak","Malposition of Device","Fluid\u002FBlood Leak","ed8e4d4b17465e1082f933f0793bd617b2551739f613c1e5d47b0fceb0fb5a43","2026-08-24T04:59:09.208125+00:00",{"items":179,"total":50},[],{"items":181,"total":50},[],{"items":183,"total":52},[184,188,193,197,200,204,207,209,211,214,217],{"pma_number":38,"supplement_number":185,"trade_name":186,"applicant":187,"decision_date":159},"S003","Tendyne Transcatheter Mitral Valve System","ABBOTT MEDICAL",{"pma_number":40,"supplement_number":189,"trade_name":190,"applicant":191,"decision_date":192},"S006","Edwards SAPIEN M3 Dock (988DDS); Edwards 23F Guide Sheath (9880GS); Edwards SAPIEN M3 Crimper (9880CR); Edwards Commande","Edwards Lifesciences, LLC","2026-07-29",{"pma_number":40,"supplement_number":194,"trade_name":195,"applicant":191,"decision_date":196},"S005","SAPIEN M3 Transcatheter Heart Valve (9880TFX29M)","2026-07-28",{"pma_number":40,"supplement_number":185,"trade_name":198,"applicant":191,"decision_date":199},"SAPIEN M3 Transcatheter Mitral Valve Replacement System","2026-04-16",{"pma_number":40,"supplement_number":201,"trade_name":202,"applicant":191,"decision_date":203},"S002","Edwards SAPIEN M3 Transcatheter Heart Valve (sizes 20mm, 23mm, 26mm, 29mm)","2026-03-11",{"pma_number":40,"supplement_number":205,"trade_name":198,"applicant":191,"decision_date":206},"S001","2026-02-19",{"pma_number":40,"supplement_number":9,"trade_name":198,"applicant":191,"decision_date":208},"2025-12-22",{"pma_number":38,"supplement_number":201,"trade_name":186,"applicant":187,"decision_date":210},"2025-10-04",{"pma_number":38,"supplement_number":205,"trade_name":212,"applicant":187,"decision_date":213},"Tendyne Transcatheter Mitral Valve","2025-07-29",{"pma_number":38,"supplement_number":9,"trade_name":215,"applicant":187,"decision_date":216},"Tendyne Transcatheter Mitral Valve System","2025-05-23",{"pma_number":39,"supplement_number":218,"trade_name":219,"applicant":191,"decision_date":220},"S162","Edwards SAPIEN 3, SAPIEN 3 Ultra, and SAPIEN 3 Ultra RESILIA Transcatheter Heart Valve Systems","2024-05-23"]