[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-OJX":3},{"classification":4,"mappedDevices":65,"similarCandidates":66,"relatedClassifications":149,"syncDates":150,"translation":157,"marketSummary":164,"recalls":188,"k510s":190,"pmas":192},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":9,"medical_specialty_description":10,"review_panel":11,"submission_type_id":12,"definition":13,"implant_flag":14,"life_sustain_support_flag":14,"gmp_exempt_flag":15,"raw":16,"created_at":59,"updated_at":60,"recall_count":61,"latest_recall_date":62,"k510_count":61,"pma_count":63,"event_count":64},4277,"OJX","Drug Eluting Permanent Left Ventricular (Lv) Pacemaker Electrode","3","","Unknown","CV","2","Drug eluting permanent lv pacemaker electrodes are used with compatible cardiac rhythm therapy (crt) devices to deliver pacing pulses to the heart.",true,false,{"openfda":17,"definition":13,"device_name":7,"review_code":9,"device_class":8,"implant_flag":56,"product_code":6,"review_panel":11,"gmp_exempt_flag":57,"third_party_flag":57,"medical_specialty":9,"regulation_number":9,"submission_type_id":12,"unclassified_reason":9,"life_sustain_support_flag":56,"medical_specialty_description":10,"summary_malfunction_reporting":58},{"fei_number":18,"pma_number":40,"registration_number":48},[19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39],"2017865","3013500228","3018094310","1220452","2649622","1028232","3002807576","3009380063","3003574398","3000203466","3013288201","3006705815","2182208","3002618605","2124215","3002806500","3013596024","3000206435","3008377825","2648729","3012552532",[41,42,43,44,45,46,47],"P060039","P010015","P010012","P080006","P050023","P030054","P050046",[49,50,51,19,20,21,22,23,52,24,26,53,29,30,31,54,33,35,55,38,39],"9610139","2032521","2030624","3008494315","2133641","9616693","9614453","Y","N","Ineligible","2026-08-18T05:52:51.740364+00:00","2026-08-24T02:00:48.882786+00:00",0,null,394,52075,[],[67,76,84,93,101,108,116,125,133,141],{"medical_device_id":68,"generic_name":69,"class_classification":70,"jmdn_code":71,"name_similarity":72,"definition_similarity":73,"vector_similarity":74,"score":75},202,"植込み型両心室同期ペースメーカ","Ⅳ","70484009",0.27027,0.215613,0.742311,0.0317781,{"medical_device_id":77,"generic_name":78,"class_classification":70,"jmdn_code":79,"name_similarity":80,"definition_similarity":81,"vector_similarity":82,"score":83},210,"ヘパリン使用体外式ペースメーカ用心臓電極","70485200",0.217391,0.247368,0.739363,0.0304147,{"medical_device_id":85,"generic_name":86,"class_classification":87,"jmdn_code":88,"name_similarity":89,"definition_similarity":90,"vector_similarity":91,"score":92},2364,"経皮ペースメーカ電極除去器具","Ⅱ","34235000",0.302632,0.20332,0.704611,0.0302135,{"medical_device_id":94,"generic_name":95,"class_classification":70,"jmdn_code":96,"name_similarity":97,"definition_similarity":98,"vector_similarity":99,"score":100},204,"心内膜植込み型ペースメーカリード","35223000",0.261905,0.255725,0.712424,0.0300769,{"medical_device_id":102,"generic_name":103,"class_classification":70,"jmdn_code":104,"name_similarity":105,"definition_similarity":106,"vector_similarity":107,"score":100},209,"体外式ペースメーカ用心臓電極","70485100",0.25974,0.256831,0.712951,{"medical_device_id":109,"generic_name":110,"class_classification":70,"jmdn_code":111,"name_similarity":112,"definition_similarity":113,"vector_similarity":114,"score":115},207,"植込み型除細動器・ペースメーカリード","36241000",0.267442,0.240741,0.690898,0.0282832,{"medical_device_id":117,"generic_name":118,"class_classification":119,"jmdn_code":120,"name_similarity":121,"definition_similarity":122,"vector_similarity":123,"score":124},542,"ペースメーカ電極アナライザ","Ⅲ","31699000",0.30303,0.281407,0.68043,0.0278877,{"medical_device_id":126,"generic_name":127,"class_classification":70,"jmdn_code":128,"name_similarity":129,"definition_similarity":130,"vector_similarity":131,"score":132},203,"心外膜植込み型ペースメーカリード","35039000",0.26506,0.179894,0.688682,0.0272059,{"medical_device_id":134,"generic_name":135,"class_classification":87,"jmdn_code":136,"name_similarity":137,"definition_similarity":138,"vector_similarity":139,"score":140},2365,"経食道体外型心臓ペースメーカ用電極","41474000",0.224719,0.258929,0.679509,0.0258564,{"medical_device_id":142,"generic_name":143,"class_classification":70,"jmdn_code":144,"name_similarity":145,"definition_similarity":146,"vector_similarity":147,"score":148},306,"ペースメーカ・除細動器リード抜去キット","18111000",0.159091,0.20362,0.686843,0.0239598,[],{"510k":151,"classification":152,"enforcement":153,"event":154,"pma":155,"warning_letter":156},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":158,"definition_ja":159,"commentary_ja":160,"model_name":161,"source_hash":162,"reviewed_by":62,"reviewed_at":62,"created_at":163,"updated_at":163},"薬剤溶出型永久使用左室ペースメーカ電極","薬剤溶出型永久使用左室ペースメーカ電極は、適合する心臓リズム治療（CRT）機器と共に使用され、心臓にペーシングパルスを送達するために用いられる。","本品は米国においてクラスIIIに分類されており、市販前承認（PMA）による審査の対象となっています。クラスIIIはFDAの機器分類の中で最も規制が厳格な区分であり、生命維持や健康への重大なリスクに関わる機器、または有効性・安全性の評価に十分な科学的根拠が確立されていない機器が該当し、市販前届出（510(k)）ではなく、より詳細な臨床データ等に基づく個別審査であるPMAが要求されます。","claude-sonnet-5","7d8ebfb5974915b551a7b47862ae6b173995b705db2a562be65fb90204aebe99","2026-08-24T02:21:53.785012+00:00",{"product_code":6,"summary_ja":165,"stats":166,"stats_hash":186,"model_name":161,"created_at":187,"updated_at":187},"本製品はPMA区分の医療機器で、これまでに本承認3件、一部変更承認は約390件が行われており、直近でも2026年6月に承認判定が出ています。不具合報告は累計で約52,000件に上り、死亡が1856件、傷害が約29,000件、不具合（Malfunction）が約21,000件と、傷害の報告が大半を占めています。主な問題としてはHigh Capture Threshold（捕捉閾値上昇）、Device Dislodged or Dislocated（デバイスの位置ずれ・脱落）、Failure to Capture（捕捉不全）が挙げられています。なお、回収に関する報告は確認されていません。",{"pma":167,"k510":171,"as_of":172,"events":173,"recalls":180,"top_problems":182},{"latest":168,"originals":169,"supplements":170},"2026-06-24",3,391,{"total":61,"last5y":61,"latest":62,"applicants":61},"2026-08",{"death":174,"other":175,"total":64,"injury":176,"last5y":177,"malfunction":178,"latest_month":179},1856,33,29267,17251,20919,"2026-07",{"total":61,"last5y":61,"latest":62,"class_i":61,"class_ii":61,"class_iii":61,"top_root_causes":181},[],[183,184,185],"High Capture Threshold","Device Dislodged or Dislocated","Failure to Capture","a785dd96220eec1567648e9351934652a7122ac8b72831e2cce541a47886a1fe","2026-08-24T05:03:24.690751+00:00",{"items":189,"total":61},[],{"items":191,"total":61},[],{"items":193,"total":63},[194,198,202,206,210,214,217,221,225,229,231,234,236,239,242,245,248,252,255,258],{"pma_number":44,"supplement_number":195,"trade_name":196,"applicant":197,"decision_date":168},"S193","Attain Ability Lead (4196, 4296), Attain Ability Lead (4396), Attain Performa Lead (4298, 4398, 4598), Attain Stability","Medtronic, Inc.",{"pma_number":44,"supplement_number":199,"trade_name":200,"applicant":197,"decision_date":201},"S192","Attain Ability Lead, Attain Performa Lead (4398,4598), Attain Performa Lead (4298), Attain Stability Quad MRI Lead","2026-04-15",{"pma_number":41,"supplement_number":203,"trade_name":204,"applicant":197,"decision_date":205},"S119","Attain StarFix Lead","2026-02-10",{"pma_number":44,"supplement_number":207,"trade_name":208,"applicant":197,"decision_date":209},"S191","MEDTRONIC ATTAIN ABILITY MODEL 4196 LEAD","2025-05-14",{"pma_number":44,"supplement_number":211,"trade_name":212,"applicant":197,"decision_date":213},"S190","Medtronic Attain Ability Model 4196 Lead","2025-03-20",{"pma_number":41,"supplement_number":215,"trade_name":216,"applicant":197,"decision_date":213},"S118","Attain Starfix Model 4195 Lead",{"pma_number":44,"supplement_number":218,"trade_name":219,"applicant":197,"decision_date":220},"S189","Attain Ability Lead","2025-02-26",{"pma_number":44,"supplement_number":222,"trade_name":223,"applicant":197,"decision_date":224},"S188","Attain Performa Lead, Attain Stability Quad MRI Lead","2025-01-22",{"pma_number":44,"supplement_number":226,"trade_name":227,"applicant":197,"decision_date":228},"S187","Attain Ability Lead, Attain Performa Lead, Attain Stability Quad MRI Lead","2024-11-13",{"pma_number":41,"supplement_number":230,"trade_name":204,"applicant":197,"decision_date":228},"S117",{"pma_number":44,"supplement_number":232,"trade_name":227,"applicant":197,"decision_date":233},"S186","2024-10-17",{"pma_number":41,"supplement_number":235,"trade_name":204,"applicant":197,"decision_date":233},"S116",{"pma_number":44,"supplement_number":237,"trade_name":227,"applicant":197,"decision_date":238},"S185","2024-08-01",{"pma_number":44,"supplement_number":240,"trade_name":223,"applicant":197,"decision_date":241},"S184","2024-06-27",{"pma_number":44,"supplement_number":243,"trade_name":227,"applicant":197,"decision_date":244},"S183","2024-04-16",{"pma_number":44,"supplement_number":246,"trade_name":219,"applicant":197,"decision_date":247},"S182","2023-12-13",{"pma_number":44,"supplement_number":249,"trade_name":250,"applicant":197,"decision_date":251},"S180","Attain Performa Lead","2023-11-17",{"pma_number":44,"supplement_number":253,"trade_name":223,"applicant":197,"decision_date":254},"S181","2023-11-08",{"pma_number":44,"supplement_number":256,"trade_name":227,"applicant":197,"decision_date":257},"S179","2023-11-03",{"pma_number":41,"supplement_number":259,"trade_name":204,"applicant":197,"decision_date":257},"S115"]