[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-PSR":3},{"classification":4,"mappedDevices":34,"similarCandidates":35,"relatedClassifications":117,"syncDates":118,"translation":125,"marketSummary":132,"recalls":151,"k510s":153,"pmas":155},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":9,"medical_specialty_description":10,"review_panel":11,"submission_type_id":12,"definition":13,"implant_flag":14,"life_sustain_support_flag":15,"gmp_exempt_flag":15,"raw":16,"created_at":28,"updated_at":29,"recall_count":30,"latest_recall_date":31,"k510_count":30,"pma_count":32,"event_count":33},3598,"PSR","Implanted Phrenic Nerve Stimulator For Central Sleep Apnea","3","","Unknown","AN","2","The device is intended to stimulate the phrenic nerve to produce diaphragm movement during sleep.",true,false,{"openfda":17,"definition":13,"device_name":7,"review_code":9,"device_class":8,"implant_flag":25,"product_code":6,"review_panel":11,"gmp_exempt_flag":26,"third_party_flag":26,"medical_specialty":9,"regulation_number":9,"submission_type_id":12,"unclassified_reason":9,"life_sustain_support_flag":26,"medical_specialty_description":10,"summary_malfunction_reporting":27},{"fei_number":18,"pma_number":22,"registration_number":24},[19,20,21],"3009144177","3010326622","1035166",[23],"P160039",[19,20,21],"Y","N","Ineligible","2026-08-18T05:52:51.341121+00:00","2026-08-24T02:00:48.620842+00:00",0,null,11,34,[],[36,45,53,61,69,78,85,93,101,109],{"medical_device_id":37,"generic_name":38,"class_classification":39,"jmdn_code":40,"name_similarity":41,"definition_similarity":42,"vector_similarity":43,"score":44},320,"横隔神経電気刺激装置","Ⅳ","35652000",0.38806,0.215139,0.871543,0.0327869,{"medical_device_id":46,"generic_name":47,"class_classification":39,"jmdn_code":48,"name_similarity":49,"definition_similarity":50,"vector_similarity":51,"score":52},6,"心臓・中枢神経刺激用プローブ","36957004",0.390625,0.168919,0.70033,0.0302135,{"medical_device_id":54,"generic_name":55,"class_classification":39,"jmdn_code":56,"name_similarity":57,"definition_similarity":58,"vector_similarity":59,"score":60},294,"昏睡覚醒用迷走神経電気刺激装置","37310000",0.240964,0.137615,0.755262,0.0292063,{"medical_device_id":62,"generic_name":63,"class_classification":39,"jmdn_code":64,"name_similarity":65,"definition_similarity":66,"vector_similarity":67,"score":68},1143,"舌下神経電気刺激装置","60360004",0.230769,0.144404,0.755634,0.0287873,{"medical_device_id":70,"generic_name":71,"class_classification":72,"jmdn_code":73,"name_similarity":74,"definition_similarity":75,"vector_similarity":76,"score":77},1623,"局所麻酔用神経刺激装置","Ⅱ","37042000",0.263889,0.177358,0.703714,0.0283702,{"medical_device_id":79,"generic_name":80,"class_classification":39,"jmdn_code":81,"name_similarity":57,"definition_similarity":82,"vector_similarity":83,"score":84},299,"抗発作用迷走神経電気刺激装置","34210000",0.131488,0.707913,0.0280833,{"medical_device_id":86,"generic_name":87,"class_classification":39,"jmdn_code":88,"name_similarity":89,"definition_similarity":90,"vector_similarity":91,"score":92},295,"精神療法用迷走神経電気刺激装置","37311000",0.224719,0.151832,0.712468,0.0277303,{"medical_device_id":94,"generic_name":95,"class_classification":39,"jmdn_code":96,"name_similarity":97,"definition_similarity":98,"vector_similarity":99,"score":100},321,"植込み型末梢神経無痛法用電気刺激装置","38474000",0.329545,0.135542,0.670771,0.0276377,{"medical_device_id":102,"generic_name":103,"class_classification":39,"jmdn_code":104,"name_similarity":105,"definition_similarity":106,"vector_similarity":107,"score":108},292,"血圧頸動脈洞枝電気刺激装置","35369000",0.240506,0.162791,0.69802,0.0274024,{"medical_device_id":110,"generic_name":111,"class_classification":72,"jmdn_code":112,"name_similarity":113,"definition_similarity":114,"vector_similarity":115,"score":116},1469,"顔面神経刺激装置","35724000",0.306452,0.163043,0.669813,0.0269886,[],{"510k":119,"classification":120,"enforcement":121,"event":122,"pma":123,"warning_letter":124},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":126,"definition_ja":127,"commentary_ja":128,"model_name":129,"source_hash":130,"reviewed_by":31,"reviewed_at":31,"created_at":131,"updated_at":131},"中枢性睡眠時無呼吸治療用植込み型横隔神経刺激装置","本device は、睡眠中に横隔膜運動を生じさせるために横隔神経を刺激することを目的とする。","この機器は米国においてクラスIIIに分類されており、市販前承認（PMA）の対象となっています。クラスIIIは人体へのリスクが最も高いとされる機器区分であり、有効性および安全性を示す科学的なデータに基づく厳格な審査を経て承認される必要があります。","claude-sonnet-5","947fa61186e26b7a4377d495c14726155f8dd493e919a1495dec028bf331e782","2026-08-24T02:33:49.041043+00:00",{"product_code":6,"summary_ja":133,"stats":134,"stats_hash":149,"model_name":129,"created_at":150,"updated_at":150},"本製品はクラスIIIのPMA対象機器であり、これまでに本承認が1件、一部変更承認が約10件行われ、直近の判定は2025年5月となっています。510(k)による市場参入や回収の実績は確認されていません。不具合報告は累計約30件で、その大半が傷害（Injury）として報告されており、死亡報告は確認されていません。主な問題としてはCompatibility Problem（互換性の問題）およびPatient Device Interaction Problem（患者と機器の相互作用に関する問題）が挙げられています。",{"pma":135,"k510":139,"as_of":140,"events":141,"recalls":144,"top_problems":146},{"latest":136,"originals":137,"supplements":138},"2025-05-07",1,10,{"total":30,"last5y":30,"latest":31,"applicants":30},"2026-08",{"death":30,"other":30,"total":33,"injury":142,"last5y":33,"malfunction":137,"latest_month":143},33,"2026-04",{"total":30,"last5y":30,"latest":31,"class_i":30,"class_ii":30,"class_iii":30,"top_root_causes":145},[],[147,148],"Compatibility Problem","Patient Device Interaction Problem","165e459ffe9503693a07ba73ee58b1876ec1dbf77e627792826757b491972277","2026-08-24T05:13:39.867404+00:00",{"items":152,"total":30},[],{"items":154,"total":30},[],{"items":156,"total":32},[157,161,165,169,172,175,178,181,185,188,191],{"pma_number":23,"supplement_number":158,"trade_name":159,"applicant":160,"decision_date":136},"S011","remede System","Respicardia",{"pma_number":23,"supplement_number":162,"trade_name":163,"applicant":160,"decision_date":164},"S009","remede System IPG","2023-11-09",{"pma_number":23,"supplement_number":166,"trade_name":167,"applicant":160,"decision_date":168},"S008","remede® System","2023-03-28",{"pma_number":23,"supplement_number":170,"trade_name":167,"applicant":160,"decision_date":171},"S007","2022-01-10",{"pma_number":23,"supplement_number":173,"trade_name":159,"applicant":160,"decision_date":174},"S006","2021-07-28",{"pma_number":23,"supplement_number":176,"trade_name":167,"applicant":160,"decision_date":177},"S005","2019-12-23",{"pma_number":23,"supplement_number":179,"trade_name":167,"applicant":160,"decision_date":180},"S004","2019-01-30",{"pma_number":23,"supplement_number":182,"trade_name":183,"applicant":160,"decision_date":184},"S002","Remede® System","2018-11-02",{"pma_number":23,"supplement_number":186,"trade_name":183,"applicant":160,"decision_date":187},"S003","2018-09-12",{"pma_number":23,"supplement_number":189,"trade_name":167,"applicant":160,"decision_date":190},"S001","2017-12-21",{"pma_number":23,"supplement_number":9,"trade_name":167,"applicant":160,"decision_date":192},"2017-10-06"]