[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-QAD":3},{"classification":4,"mappedDevices":41,"similarCandidates":42,"relatedClassifications":43,"syncDates":44,"translation":51,"marketSummary":58,"recalls":81,"k510s":83,"pmas":108},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":10,"medical_specialty_description":11,"review_panel":10,"submission_type_id":12,"definition":13,"implant_flag":14,"life_sustain_support_flag":15,"gmp_exempt_flag":15,"raw":16,"created_at":35,"updated_at":36,"recall_count":37,"latest_recall_date":38,"k510_count":39,"pma_count":37,"event_count":40},5758,"QAD","Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated","2","888.3023","OR","Orthopedic","1","Is a device intended to be implanted that consists of a polymeric balloon that is inserted into the medullary (bone marrow) canal of long bones for the fixation of fractures.  The balloon is infused with a liquid monomer that causes the balloon to fill the medullary canal of the fractured bone. The device is then exposed to a light source that polymerizes the light-activated monomer within the balloon creating a hardened rigid structure.",true,false,{"openfda":17,"definition":13,"device_name":7,"review_code":31,"device_class":8,"implant_flag":32,"product_code":6,"review_panel":10,"gmp_exempt_flag":33,"third_party_flag":33,"medical_specialty":10,"regulation_number":9,"submission_type_id":12,"unclassified_reason":31,"life_sustain_support_flag":33,"medical_specialty_description":11,"summary_malfunction_reporting":34},{"k_number":18,"fei_number":26,"registration_number":29},[19,20,21,22,23,24,25],"K233436","DEN160062","K200295","K183145","K181228","K202887","K201961",[27,28],"1000120776","3006845464",[30,28],"1222747","","Y","N","Ineligible","2026-08-18T05:52:52.949882+00:00","2026-08-24T02:00:47.808424+00:00",0,null,7,156,[],[],[],{"510k":45,"classification":46,"enforcement":47,"event":48,"pma":49,"warning_letter":50},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":52,"definition_ja":53,"commentary_ja":54,"model_name":55,"source_hash":56,"reviewed_by":38,"reviewed_at":38,"created_at":57,"updated_at":57},"光重合式髄内固定ロッド（体内硬化型）及び附属品","本品は、長管骨骨折の固定のために髄腔（骨髄腔）内に挿入される高分子製バルーンからなる、植込みを意図した医療機器である。バルーンには液状モノマーが注入され、これにより骨折した骨の髄腔を満たすようにバルーンが拡張する。その後、本品は光源に曝露され、バルーン内の光重合性モノマーが重合することにより硬化した剛性構造体が形成される。","本品は米国FDAの分類においてクラスIIに区分され、市販前届出（510(k)）による審査を経て市場に流通することが求められる医療機器です。クラスIIは、疾病や傷害のリスクが中程度であり、一般的な管理に加えて特別な管理を講じることで安全性及び有効性を確保できると判断される機器に適用される区分です。510(k)による審査では、既に合法的に販売されている同種の機器との実質的同等性を示すことによって市販が認められます。","claude-sonnet-5","66bf5ee6d861786c806a803dc85b57097ab1517c72473a7fa509994a590fbe6b","2026-08-24T02:35:22.423427+00:00",{"product_code":6,"summary_ja":59,"stats":60,"stats_hash":79,"model_name":55,"created_at":80,"updated_at":80},"510(k)としては累計約7件が届出されており、参入企業は2社、直近5年では約1件の実績があり、最新の判定は2024年1月となっています。PMAでの承認実績は確認されていません。不具合報告（MDR）は累計約160件で、死亡14件、傷害約60件、不具合（Malfunction）約90件と幅広い内訳となっており、直近5年では約130件、最新の報告は2026年6月です。主な問題としてはGel Leak（ゲル漏出）、Material Separation（材料分離）、Fracture（破損）が挙げられています。回収（リコール）の実績は確認されていません。",{"pma":61,"k510":62,"as_of":66,"events":67,"recalls":73,"top_problems":75},{"latest":38,"originals":37,"supplements":37},{"total":39,"last5y":63,"latest":64,"applicants":65},1,"2024-01-19",2,"2026-08",{"death":68,"other":37,"total":40,"injury":69,"last5y":70,"malfunction":71,"latest_month":72},14,57,129,85,"2026-06",{"total":37,"last5y":37,"latest":38,"class_i":37,"class_ii":37,"class_iii":37,"top_root_causes":74},[],[76,77,78],"Gel Leak","Material Separation","Fracture","95b7246e04083ec342cb691c950910d31b2970ea7807fb154109a1c216748006","2026-08-24T05:15:00.389328+00:00",{"items":82,"total":37},[],{"items":84,"total":39},[85,91,95,97,99,101,103],{"k_number":19,"device_name":86,"applicant":87,"decision_date":64,"clearance_type":88,"decision_code":89,"statement_or_summary":90},"IlluminOss Photodynamic Bone Stabilization System","Illuminoss Medical, Inc.","Traditional","SESE","Summary",{"k_number":24,"device_name":92,"applicant":87,"decision_date":93,"clearance_type":94,"decision_code":89,"statement_or_summary":90},"IlluminOss Bone Stabilization System","2020-10-27","Special",{"k_number":25,"device_name":86,"applicant":87,"decision_date":96,"clearance_type":94,"decision_code":89,"statement_or_summary":90},"2020-08-13",{"k_number":21,"device_name":92,"applicant":87,"decision_date":98,"clearance_type":88,"decision_code":89,"statement_or_summary":90},"2020-06-25",{"k_number":22,"device_name":86,"applicant":87,"decision_date":100,"clearance_type":94,"decision_code":89,"statement_or_summary":90},"2018-12-13",{"k_number":23,"device_name":92,"applicant":87,"decision_date":102,"clearance_type":88,"decision_code":89,"statement_or_summary":90},"2018-08-31",{"k_number":20,"device_name":92,"applicant":104,"decision_date":105,"clearance_type":106,"decision_code":107,"statement_or_summary":38},"Illminoss Medical, Inc.","2017-12-19","Direct","DENG",{"items":109,"total":37},[]]