[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-QLO":3},{"classification":4,"mappedDevices":26,"similarCandidates":27,"relatedClassifications":110,"syncDates":111,"translation":118,"marketSummary":125,"recalls":144,"k510s":146,"pmas":148},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":9,"medical_specialty_description":10,"review_panel":11,"submission_type_id":12,"definition":13,"implant_flag":14,"life_sustain_support_flag":15,"gmp_exempt_flag":14,"raw":16,"created_at":21,"updated_at":22,"recall_count":23,"latest_recall_date":24,"k510_count":23,"pma_count":23,"event_count":25},972,"QLO","Immunoadsorption Column For Emergency Use","N","","Unknown","GU","8","Extracorporeal carbon dioxide removal from blood for use during declared public health emergency.",false,true,{"openfda":17,"definition":13,"device_name":7,"review_code":9,"device_class":8,"implant_flag":8,"product_code":6,"review_panel":11,"gmp_exempt_flag":8,"third_party_flag":8,"medical_specialty":9,"regulation_number":9,"submission_type_id":12,"unclassified_reason":18,"life_sustain_support_flag":19,"medical_specialty_description":10,"summary_malfunction_reporting":20},{},"11","Y","Ineligible","2026-08-18T05:52:48.222586+00:00","2026-08-24T02:00:48.758894+00:00",0,null,27,[],[28,37,45,53,61,70,78,86,94,102],{"medical_device_id":29,"generic_name":30,"class_classification":31,"jmdn_code":32,"name_similarity":33,"definition_similarity":34,"vector_similarity":35,"score":36},740,"吸着型血液浄化器","Ⅲ","34422000",0.285714,0.181395,0.749026,0.0322665,{"medical_device_id":38,"generic_name":39,"class_classification":31,"jmdn_code":40,"name_similarity":41,"definition_similarity":42,"vector_similarity":43,"score":44},750,"エンドトキシン除去向け吸着型血液浄化用浄化器","70535000",0.236111,0.187919,0.755532,0.0317781,{"medical_device_id":46,"generic_name":47,"class_classification":31,"jmdn_code":48,"name_similarity":49,"definition_similarity":50,"vector_similarity":51,"score":52},743,"吸着型血漿浄化器","70532000",0.275862,0.150289,0.744454,0.031754,{"medical_device_id":54,"generic_name":55,"class_classification":31,"jmdn_code":56,"name_similarity":57,"definition_similarity":58,"vector_similarity":59,"score":60},755,"エンドトキシン除去向け吸着型血液浄化用装置","35104020",0.197368,0.240602,0.73143,0.0300905,{"medical_device_id":62,"generic_name":63,"class_classification":64,"jmdn_code":65,"name_similarity":66,"definition_similarity":67,"vector_similarity":68,"score":69},2392,"エンドトキシン除去向け吸着型血液浄化用血液回路","Ⅱ","70554000",0.164706,0.292683,0.726069,0.0290099,{"medical_device_id":71,"generic_name":72,"class_classification":31,"jmdn_code":73,"name_similarity":74,"definition_similarity":75,"vector_similarity":76,"score":77},754,"吸着型血液浄化用装置","35104010",0.183099,0.180328,0.710567,0.0285714,{"medical_device_id":79,"generic_name":80,"class_classification":31,"jmdn_code":81,"name_similarity":82,"definition_similarity":83,"vector_similarity":84,"score":85},432,"緊急時ブラッドアクセス留置用カテーテル","70320100",0.164384,0.174242,0.707909,0.0268759,{"medical_device_id":87,"generic_name":88,"class_classification":31,"jmdn_code":89,"name_similarity":90,"definition_similarity":91,"vector_similarity":92,"score":93},752,"血球細胞除去用浄化器","70537000",0.12963,0.215385,0.720893,0.0266106,{"medical_device_id":95,"generic_name":96,"class_classification":31,"jmdn_code":97,"name_similarity":98,"definition_similarity":99,"vector_similarity":100,"score":101},433,"抗菌作用緊急時ブラッドアクセス留置用カテーテル","70320200",0.141176,0.181435,0.679732,0.0237093,{"medical_device_id":103,"generic_name":104,"class_classification":31,"jmdn_code":105,"name_similarity":106,"definition_similarity":107,"vector_similarity":108,"score":109},762,"血球細胞除去用装置","70542000",0.03125,0.155039,0.753562,0.016129,[],{"510k":112,"classification":113,"enforcement":114,"event":115,"pma":116,"warning_letter":117},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":119,"definition_ja":120,"commentary_ja":121,"model_name":122,"source_hash":123,"reviewed_by":24,"reviewed_at":24,"created_at":124,"updated_at":124},"緊急使用向け免疫吸着カラム","公衆衛生上の緊急事態が宣言された期間中に使用するための、血液からの体外二酸化炭素除去である。","本品は米国では通常のデバイスクラス（クラスI・II・III）には分類されておらず、公衆衛生上の緊急事態宣言下でのみ使用が認められるEUA（緊急使用許可）という特別な審査区分に基づいて市場に供給される製品です。EUAは通常の市販前届出（510(k)）や市販前承認（PMA）とは異なり、緊急事態への対応として一時的に使用が許可される仕組みであり、対応する21 CFR番号も定められていません。","claude-sonnet-5","b4bc55bfac6bfa006e588f755b20251943b8f6d6b47443dfb34057177b044bd7","2026-08-24T03:31:52.244646+00:00",{"product_code":6,"summary_ja":126,"stats":127,"stats_hash":142,"model_name":122,"created_at":143,"updated_at":143},"本製品コードについては、510(k)およびPMAの承認・届出実績は確認されていません。不具合報告は累計約30件寄せられており、その内訳は死亡7件、傷害18件、不具合2件と、死亡・傷害の報告が大半を占めています。主な問題としては、患者と機器の相互作用に関する問題（Patient Device Interaction Problem）、効果の欠如（Lack of Effect）、完全閉塞（Complete Blockage）が挙げられています。なお、回収の実績は確認されていません。",{"pma":128,"k510":129,"as_of":130,"events":131,"recalls":136,"top_problems":138},{"latest":24,"originals":23,"supplements":23},{"total":23,"last5y":23,"latest":24,"applicants":23},"2026-08",{"death":132,"other":23,"total":25,"injury":133,"last5y":25,"malfunction":134,"latest_month":135},7,18,2,"2025-08",{"total":23,"last5y":23,"latest":24,"class_i":23,"class_ii":23,"class_iii":23,"top_root_causes":137},[],[139,140,141],"Patient Device Interaction Problem","Lack of Effect","Complete Blockage","74a1a30226fc473b09842554406ce36a0c30ab9805e2eebdacec450d836aa1c0","2026-08-24T05:19:21.416523+00:00",{"items":145,"total":23},[],{"items":147,"total":23},[],{"items":149,"total":23},[]]