[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-device-SEG":3},{"classification":4,"mappedDevices":33,"similarCandidates":34,"relatedClassifications":114,"syncDates":115,"translation":122,"marketSummary":129,"recalls":151,"k510s":153,"pmas":155},{"id":5,"product_code":6,"device_name":7,"device_class":8,"regulation_number":9,"medical_specialty":9,"medical_specialty_description":10,"review_panel":11,"submission_type_id":12,"definition":13,"implant_flag":14,"life_sustain_support_flag":15,"gmp_exempt_flag":15,"raw":16,"created_at":27,"updated_at":28,"recall_count":29,"latest_recall_date":30,"k510_count":29,"pma_count":31,"event_count":32},3880,"SEG","Leadless Cardiac Resynchronization Therapy (Crt)","3","","Unknown","CV","2","Leadless Cardiac Resynchronization Therapy (CRT) is intended to deliver CRT using a leadless left ventricular implant",true,false,{"openfda":17,"definition":13,"device_name":7,"review_code":9,"device_class":8,"implant_flag":24,"product_code":6,"review_panel":11,"gmp_exempt_flag":25,"third_party_flag":25,"medical_specialty":9,"regulation_number":9,"submission_type_id":12,"unclassified_reason":9,"life_sustain_support_flag":25,"medical_specialty_description":10,"summary_malfunction_reporting":26},{"fei_number":18,"pma_number":21,"registration_number":23},[19,20],"3044322716","3013596742",[22],"P240028",[19,20],"Y","N","Ineligible","2026-08-18T05:52:51.341121+00:00","2026-08-24T02:00:48.366308+00:00",0,null,6,96,[],[35,44,53,60,68,76,84,91,99,106],{"medical_device_id":36,"generic_name":37,"class_classification":38,"jmdn_code":39,"name_similarity":40,"definition_similarity":41,"vector_similarity":42,"score":43},1129,"植込み型リードレス心臓ペースメーカ","Ⅳ","60789004",0.25,0.141732,0.711291,0.032002,{"medical_device_id":45,"generic_name":46,"class_classification":47,"jmdn_code":48,"name_similarity":49,"definition_similarity":50,"vector_similarity":51,"score":52},1069,"放射線治療装置用シンクロナイザ","Ⅲ","47928000",0.4,0.165441,0.65734,0.0288934,{"medical_device_id":54,"generic_name":55,"class_classification":38,"jmdn_code":56,"name_similarity":29,"definition_similarity":57,"vector_similarity":58,"score":59},202,"植込み型両心室同期ペースメーカ","70484009",0.266667,0.751114,0.0163934,{"medical_device_id":61,"generic_name":62,"class_classification":38,"jmdn_code":63,"name_similarity":64,"definition_similarity":65,"vector_similarity":66,"score":67},75,"心臓用カテーテルイントロデューサキット","10598000",0.263158,0.197802,0.54614,0.016129,{"medical_device_id":69,"generic_name":70,"class_classification":38,"jmdn_code":71,"name_similarity":72,"definition_similarity":73,"vector_similarity":74,"score":75},207,"植込み型除細動器・ペースメーカリード","36241000",0.0430108,0.166667,0.704116,0.015873,{"medical_device_id":77,"generic_name":78,"class_classification":38,"jmdn_code":79,"name_similarity":80,"definition_similarity":81,"vector_similarity":82,"score":83},25,"再使用可能な心臓吸引用針","44136000",0.230769,0.133621,0.553823,0.015625,{"medical_device_id":85,"generic_name":86,"class_classification":38,"jmdn_code":87,"name_similarity":88,"definition_similarity":89,"vector_similarity":90,"score":83},1114,"心臓組織用クリップ","35649004",0.0428571,0.172043,0.692784,{"medical_device_id":92,"generic_name":93,"class_classification":38,"jmdn_code":94,"name_similarity":95,"definition_similarity":96,"vector_similarity":97,"score":98},308,"中心循環系手動式放射線ブラキセラピー装置","38299004",0.107843,0.139241,0.687374,0.0153846,{"medical_device_id":100,"generic_name":101,"class_classification":47,"jmdn_code":102,"name_similarity":103,"definition_similarity":104,"vector_similarity":105,"score":98},884,"放射線治療シミュレータ","35294000",0.233333,0.116279,0.519189,{"medical_device_id":107,"generic_name":108,"class_classification":38,"jmdn_code":109,"name_similarity":110,"definition_similarity":111,"vector_similarity":112,"score":113},307,"中心循環系アフターローディング式ブラキセラピー装置","38300004",0.106195,0.149321,0.686896,0.0151515,[],{"510k":116,"classification":117,"enforcement":118,"event":119,"pma":120,"warning_letter":121},"2026-08-24T02:00:50.297+00:00","2026-08-24T02:00:49.319+00:00","2026-08-24T02:00:50.059+00:00","2026-08-24T04:00:49.186+00:00","2026-08-24T02:00:50.609+00:00","2026-08-20T03:28:02.95+00:00",{"product_code":6,"device_name_ja":123,"definition_ja":124,"commentary_ja":125,"model_name":126,"source_hash":127,"reviewed_by":30,"reviewed_at":30,"created_at":128,"updated_at":128},"リードレス心臓再同期療法用植込み型装置","リードレス心臓再同期療法（CRT）は、リードレス左心室植込み型装置を用いてCRTを行うことを目的とする。","この機器は米国においてクラスIIIに分類されており、市販前承認（PMA）による審査を受ける区分に該当します。クラスIIIはFDAの分類の中で最もリスクが高いとされる区分であり、有効性及び安全性を示す科学的根拠を含む詳細な審査資料の提出が求められます。","claude-sonnet-5","4d5e0860cb46a1f7b1e815ef2fd853b44be50926cf1282c22c57d097fd0e847f","2026-08-24T03:40:21.731962+00:00",{"product_code":6,"summary_ja":130,"stats":131,"stats_hash":149,"model_name":126,"created_at":150,"updated_at":150},"PMA区分では本承認1件、一部変更承認5件が確認されており、直近の判定は2026年3月となっています。不具合報告は累計約100件で、死亡7件、傷害約20件、不具合（Malfunction）約70件が含まれ、主な問題として通信・伝送の問題（Communication or Transmission Problem）、電気・電子的特性の問題（Electrical\u002FElectronic Property Problem）、電源の問題（Power Problem）が挙げられています。回収については累計件数は確認されていません。",{"pma":132,"k510":136,"as_of":137,"events":138,"recalls":143,"top_problems":145},{"latest":133,"originals":134,"supplements":135},"2026-03-27",1,5,{"total":29,"last5y":29,"latest":30,"applicants":29},"2026-08",{"death":139,"other":29,"total":32,"injury":140,"last5y":32,"malfunction":141,"latest_month":142},7,23,66,"2026-07",{"total":29,"last5y":29,"latest":30,"class_i":29,"class_ii":29,"class_iii":29,"top_root_causes":144},[],[146,147,148],"Communication or Transmission Problem","Electrical \u002FElectronic Property Problem","Power Problem","2c08d4975028a8df0b5358878e741969fa7be32617dbc51013109e3bf48b866e","2026-08-24T05:23:16.025025+00:00",{"items":152,"total":29},[],{"items":154,"total":29},[],{"items":156,"total":31},[157,161,164,168,171,174],{"pma_number":22,"supplement_number":158,"trade_name":159,"applicant":160,"decision_date":133},"S006","WiSE® (Wireless Stimulation of the Endocardium Technology) CRT System","EBR Systems, Inc.",{"pma_number":22,"supplement_number":162,"trade_name":159,"applicant":160,"decision_date":163},"S004","2025-12-15",{"pma_number":22,"supplement_number":165,"trade_name":166,"applicant":160,"decision_date":167},"S003","WiSE (Wireless Stimulation of the Endocardium Technology) CRT System","2025-10-03",{"pma_number":22,"supplement_number":169,"trade_name":159,"applicant":160,"decision_date":170},"S002","2025-09-03",{"pma_number":22,"supplement_number":172,"trade_name":159,"applicant":160,"decision_date":173},"S001","2025-06-18",{"pma_number":22,"supplement_number":9,"trade_name":159,"applicant":160,"decision_date":175},"2025-04-11"]