[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-events-search:[\"\",\"\",\"HCG\",\"1990-01-01\",\"2026-11-17\",1]":3,"fda-latest-sync-dates":233},{"events":4,"total":232},[5,25,37,46,56,65,76,94,106,117,126,135,144,156,169,179,187,198,206,217],{"mdr_report_key":6,"report_number":7,"event_type":8,"date_received":9,"date_of_event":10,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":14,"brand_name":16,"generic_name":17,"product_code":18,"manufacturer_name":19,"model_number":20,"patient_outcomes":21,"remedial_action":23,"created_at":24,"updated_at":24},"51234571","2032493-2026-08327","Malfunction","2026-10-29","2026-10-08","Manufacturer report","N","Y",[15],"Premature Separation","HydroFrame-10-AV","Device neurovascular embolization","HCG","MicroVention, Inc.","100833HFRM-V-A2",[22],"",[22],"2026-11-14T04:01:30.682575+00:00",{"mdr_report_key":26,"report_number":27,"event_type":8,"date_received":28,"date_of_event":29,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":30,"brand_name":31,"generic_name":32,"product_code":18,"manufacturer_name":33,"model_number":22,"patient_outcomes":34,"remedial_action":35,"created_at":36,"updated_at":36},"51221378","3005168196-2026-00353","2026-10-27","2026-09-16",[15],"Packing Coil LP","HCG,KRD","Penumbra, Inc.",[22],[22],"2026-11-14T04:01:15.974558+00:00",{"mdr_report_key":38,"report_number":39,"event_type":8,"date_received":28,"date_of_event":40,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":41,"brand_name":42,"generic_name":43,"product_code":18,"manufacturer_name":33,"model_number":22,"patient_outcomes":44,"remedial_action":45,"created_at":36,"updated_at":36},"51221259","3005168196-2026-00362","2026-09-29",[15],"SwiftPAC Coil","HCG, KRD",[22],[22],{"mdr_report_key":47,"report_number":48,"event_type":8,"date_received":28,"date_of_event":49,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":50,"brand_name":51,"generic_name":52,"product_code":18,"manufacturer_name":53,"model_number":22,"patient_outcomes":54,"remedial_action":55,"created_at":36,"updated_at":36},"51220843","3008881809-2026-00649","2026-09-03",[15],"TARGET 360 NANO 1MM X 3CM","Device, Neurovascular Embolization","Stryker Neurovascular Cork",[22],[22],{"mdr_report_key":57,"report_number":58,"event_type":8,"date_received":28,"date_of_event":59,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":60,"brand_name":61,"generic_name":52,"product_code":18,"manufacturer_name":53,"model_number":22,"patient_outcomes":62,"remedial_action":63,"created_at":64,"updated_at":64},"51220387","3008881809-2026-00647","2026-10-06",[15],"TARGET TETRA 2.0MM X 3.5CM",[22],[22],"2026-11-14T04:01:14.921031+00:00",{"mdr_report_key":66,"report_number":67,"event_type":8,"date_received":68,"date_of_event":69,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":70,"brand_name":72,"generic_name":52,"product_code":18,"manufacturer_name":53,"model_number":22,"patient_outcomes":73,"remedial_action":74,"created_at":75,"updated_at":75},"51205953","3008881809-2026-00646","2026-10-26","2026-10-03",[71],"Fracture","TARGET 360 SOFT 9MM X 30CM",[22],[22],"2026-11-14T04:00:51.728695+00:00",{"mdr_report_key":77,"report_number":78,"event_type":79,"date_received":80,"date_of_event":81,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":82,"brand_name":85,"generic_name":86,"product_code":18,"manufacturer_name":87,"model_number":88,"patient_outcomes":89,"remedial_action":92,"created_at":93,"updated_at":93},"51182791","3014162263-2026-00096","Injury","2026-10-22","2026-08-18",[83,84,15],"Stretched","Migration","Optima Coil System","Optima","Balt USA","OPTI0530BLK",[90,91],"Other"," R",[22],"2026-11-13T04:02:11.19251+00:00",{"mdr_report_key":95,"report_number":96,"event_type":8,"date_received":97,"date_of_event":98,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":99,"brand_name":101,"generic_name":52,"product_code":18,"manufacturer_name":19,"model_number":102,"patient_outcomes":103,"remedial_action":104,"created_at":105,"updated_at":105},"51157981","2032493-2026-08317","2026-10-20","2026-09-26",[100],"Difficult or Delayed Separation","HyperSoft-AV","100408HS-V-A2",[22],[22],"2026-11-13T04:01:45.695532+00:00",{"mdr_report_key":107,"report_number":108,"event_type":8,"date_received":97,"date_of_event":109,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":110,"brand_name":111,"generic_name":112,"product_code":18,"manufacturer_name":19,"model_number":113,"patient_outcomes":114,"remedial_action":115,"created_at":116,"updated_at":116},"51156591","2032493-2026-08314","2026-09-18",[15],"AZUR-18 Detachable Hydro","Peripheral","45-480305-03",[22],[22],"2026-11-13T04:01:44.799811+00:00",{"mdr_report_key":118,"report_number":119,"event_type":8,"date_received":97,"date_of_event":120,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":121,"brand_name":122,"generic_name":52,"product_code":18,"manufacturer_name":53,"model_number":22,"patient_outcomes":123,"remedial_action":124,"created_at":125,"updated_at":125},"51153732","3008881809-2026-00641","2026-07-31",[71],"TARGET XL 360 STANDARD 6MM X 20CM",[22],[22],"2026-11-13T04:01:40.585661+00:00",{"mdr_report_key":127,"report_number":128,"event_type":79,"date_received":97,"date_of_event":40,"report_source_code":11,"adverse_event_flag":13,"product_problem_flag":12,"product_problems":129,"brand_name":130,"generic_name":52,"product_code":18,"manufacturer_name":53,"model_number":22,"patient_outcomes":131,"remedial_action":133,"created_at":134,"updated_at":134},"51147638","3008881809-2026-00640",[71,84],"TARGET XL 360 SOFT 4MM X 8CM",[132],"Required Intervention",[22],"2026-11-13T04:01:35.23795+00:00",{"mdr_report_key":136,"report_number":137,"event_type":79,"date_received":97,"date_of_event":138,"report_source_code":11,"adverse_event_flag":13,"product_problem_flag":12,"product_problems":139,"brand_name":141,"generic_name":52,"product_code":18,"manufacturer_name":53,"model_number":22,"patient_outcomes":142,"remedial_action":143,"created_at":134,"updated_at":134},"51147594","3008881809-2026-00639","2026-09-22",[140],"Adverse Event Without Identified Device or Use Problem","TARGET 360 NANO 1.5MM X 4CM",[132],[22],{"mdr_report_key":145,"report_number":146,"event_type":8,"date_received":147,"date_of_event":148,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":149,"brand_name":151,"generic_name":52,"product_code":18,"manufacturer_name":19,"model_number":152,"patient_outcomes":153,"remedial_action":154,"created_at":155,"updated_at":155},"51147177","2032493-2026-08312","2026-10-19","2026-10-05",[150],"Unsealed Device Packaging","Helical-18-AV","180406HC-S-V-A2",[22],[22],"2026-11-13T04:01:33.932804+00:00",{"mdr_report_key":157,"report_number":157,"event_type":8,"date_received":147,"date_of_event":158,"report_source_code":159,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":160,"brand_name":162,"generic_name":163,"product_code":18,"manufacturer_name":164,"model_number":165,"patient_outcomes":166,"remedial_action":167,"created_at":168,"updated_at":168},"51131851","2026-09-08","User Facility report",[161],"Separation Failure","Swift Coil System","DEVICE, NEUROVASCULAR EMBOLIZATION","PENUMBRA, INC.","SDH1-A",[90],[22],"2026-11-13T04:01:15.257353+00:00",{"mdr_report_key":170,"report_number":171,"event_type":8,"date_received":172,"date_of_event":173,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":174,"brand_name":175,"generic_name":52,"product_code":18,"manufacturer_name":53,"model_number":22,"patient_outcomes":176,"remedial_action":177,"created_at":178,"updated_at":178},"51122956","3008881809-2026-00635","2026-10-16","2026-09-09",[71],"TARGET 360 SOFT 6MM X 30CM",[22],[22],"2026-11-13T04:01:02.465813+00:00",{"mdr_report_key":180,"report_number":181,"event_type":8,"date_received":172,"date_of_event":182,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":183,"brand_name":184,"generic_name":52,"product_code":18,"manufacturer_name":53,"model_number":22,"patient_outcomes":185,"remedial_action":186,"created_at":178,"updated_at":178},"51122829","3008881809-2026-00634","2026-06-17",[71],"TARGET XXL 360 8MM X 40CM",[22],[22],{"mdr_report_key":188,"report_number":189,"event_type":8,"date_received":190,"date_of_event":191,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":192,"brand_name":193,"generic_name":43,"product_code":18,"manufacturer_name":33,"model_number":22,"patient_outcomes":194,"remedial_action":195,"created_at":196,"updated_at":197},"51117911","3005168196-2026-00356","2026-10-15","2026-09-15",[100],"Penumbra Smart Coil",[22],[22],"2026-11-12T04:02:31.324112+00:00","2026-11-13T04:00:54.376406+00:00",{"mdr_report_key":199,"report_number":200,"event_type":8,"date_received":190,"date_of_event":201,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":202,"brand_name":203,"generic_name":43,"product_code":18,"manufacturer_name":33,"model_number":22,"patient_outcomes":204,"remedial_action":205,"created_at":196,"updated_at":197},"51117795","3005168196-2026-00355","2026-07-15",[84],"Ruby Coil",[22],[22],{"mdr_report_key":207,"report_number":208,"event_type":8,"date_received":190,"date_of_event":209,"report_source_code":11,"adverse_event_flag":12,"product_problem_flag":13,"product_problems":210,"brand_name":85,"generic_name":86,"product_code":18,"manufacturer_name":87,"model_number":212,"patient_outcomes":213,"remedial_action":214,"created_at":215,"updated_at":216},"51116894","3014162263-2026-00097","2026-08-20",[83,84,211],"Separation Problem","OPTI0256CSS10",[90],[22],"2026-11-12T04:02:30.688747+00:00","2026-11-13T04:00:53.514761+00:00",{"mdr_report_key":218,"report_number":219,"event_type":79,"date_received":220,"date_of_event":221,"report_source_code":222,"adverse_event_flag":13,"product_problem_flag":12,"product_problems":223,"brand_name":225,"generic_name":226,"product_code":18,"manufacturer_name":227,"model_number":228,"patient_outcomes":229,"remedial_action":230,"created_at":231,"updated_at":231},"51100208","3030361767-2026-00003","2026-10-14","2026-08-26","Distributor report",[224],"Unraveled Material","Numen","Coil embolization system","MicroPort NeuroTech (Shanghai) CO., LTD","3D0206FN",[22],[22],"2026-11-12T04:02:14.350859+00:00",7907,{"510k":234,"classification":235,"enforcement":236,"event":237,"event_backfill":238,"pma":239,"warning_letter":240},"2026-11-16T02:00:55.89+00:00","2026-11-16T02:00:41.999+00:00","2026-11-16T02:00:49.415+00:00","2026-11-17T04:00:34.414+00:00","2026-09-07T05:17:28.839+00:00","2026-11-16T02:01:03.155+00:00","2026-11-17T01:02:55.859+00:00"]