[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-warning-letters-search:[\"Becton, Dickinson and Company, BD Bio Sciences\",\"\",\"\",\"\",\"\",1]":3,"fda-latest-sync-dates":56},{"warningLetters":4,"total":55},[5,31],{"id":6,"raw":7,"subject":12,"body_html":14,"body_text":15,"firm_name":16,"letter_id":17,"created_at":18,"fei_number":19,"letter_url":20,"updated_at":21,"action_type":22,"case_status":23,"posted_date":24,"marcs_cms_no":25,"product_type":26,"closeout_date":19,"issuing_office":11,"recipient_name":27,"body_fetched_at":28,"delivery_method":29,"recipient_title":19,"reference_number":19,"action_taken_date":30,"medical_device_id":19,"response_letter_date":19},1134,[8,9,10,11,12,13,13,13],"\u003Ctime datetime=\"2024-12-17T14:20:00Z\">12\u002F17\u002F2024\u003C\u002Ftime>\n","\u003Ctime datetime=\"2024-11-22T05:00:00Z\">11\u002F22\u002F2024\u003C\u002Ftime>\n","\u003Ca href=\"\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fbecton-dickinson-and-companycarefusion-303-inc-691601-11222024\">Becton, Dickinson, and Company\u002FCareFusion 303, Inc.\u003C\u002Fa>","Center for Devices and Radiological Health","CGMP\u002FQSR\u002FMedical Devices\u002FAdulterated\u002FMisbranded","","\n\n                            \n                            \n                            \n                            \n                                              \n  \n \n\n                 \n\n  \u003Chr>\n \n\n\u003Cdiv>\n  \u003Cdl>\n\n              \u003Cdt>Delivery Method:\u003C\u002Fdt> \n        \u003Cdd>Via Email\n                                                                                                                                                                                                                                                                                                                                                                                                                              \u003C\u002Fdd>\n      \n      \n              \u003Cdt>Product:\u003C\u002Fdt> \n        \u003Cdd>Medical Devices                          \n            \n            \n            \n            \n            \n            \n            \n             \n            \n            \n            \n              \n            \n            \n            \u003C\u002Fdd>\n      \n          \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n\n\u003Chr>\n\n\u003Cdiv>\n  \u003Cdiv>\n    \u003Cdl>\n\n        \u003Cdt>Recipient:\u003C\u002Fdt>\n\n                      \u003Cdd>\n  \u003Cdiv>\n    \u003Cdiv>Recipient Name\u003C\u002Fdiv>\n              \u003Cdiv>Mr. Thomas E. Polen\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n                                \u003Cdd>\n  \u003Cdiv>\n    \u003Cdiv>Recipient Title\u003C\u002Fdiv>\n              \u003Cdiv>President &amp; CEO\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n          \n            \u003Cdd>Becton, Dickinson, and Company\u002FCareFusion 303, Inc.\u003C\u002Fdd>\n\n          \n                      \u003Cdd>\u003Cp>\u003Cspan>1 Becton Drive\u003C\u002Fspan>\u003Cbr>\n\u003Cspan>Franklin Lakes\u003C\u002Fspan>, \u003Cspan>NJ\u003C\u002Fspan> \u003Cspan>07417\u003C\u002Fspan>\u003Cbr>\n\u003Cspan>United States\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n          \n          \n            \n            \u003Cdd>\n\n    \u003C\u002Fdd>\u003Cdd>\u003Cspan>\u003C\u002Fspan>\u003Ca href=\"mailto:(b)(6)\"> (b)(6)\u003C\u002Fa>\u003C\u002Fdd>\n\n          \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n       \u003Cdiv>\n    \u003Cdl>\n          \n          \u003Cdt>Issuing Office:\u003C\u002Fdt>\n        \n         \n          \u003Cdd>Center for Devices and Radiological Health\u003C\u002Fdd>\n        \n         \n          \u003Cdd>\u003Cp>\u003Cspan>United States\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n        \n        \n        \n        \n        \n    \u003C\u002Fdl>\n    \u003Cdl> \n      \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>  \n      \n\u003C\u002Fdiv>\n\n \n\n \n\n\u003Chr>\n\n\u003Cp>\u003Cstrong>WARNING LETTER\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>11\u002F22\u002F2024\u003C\u002Fp>\u003Cp>Dear Mr. Polen:\u003C\u002Fp>\u003Cp>During an inspection of your firm located in San Diego, California on May 6, 2024 through May 22, 2024, an investigator (or investigators) from the United States Food and Drug Administration (FDA) determined that your firm manufactures Pyxis Medication Management System medical devices including, but not limited to, Pyxis MedStation ES, Pyxis ES Anesthesia, and Pyxis MedBank (hereafter also referred to as Pyxis) Under section 201(h) of the Federal Food, Drug, and Cosmetic Act (the Act), 21 U.S.C. § 321(h), these products are devices because they are intended for use in the diagnosis of disease or other conditions or in the cure, mitigation, treatment, or prevention of disease, or to affect the structure or any function of the body.\u003C\u002Fp>\u003Cp>\u003Cstrong>Quality System Regulation\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>This inspection revealed that these devices are adulterated within the meaning of section 501(h) of the Act, 21 U.S.C. § 351(h), in that the methods used in, or the facilities or controls used for, their manufacture, packing, storage, or installation are not in conformity with the current good manufacturing practice requirements of the Quality System regulation found at Title 21, \u003Cu>Code of Federal Regulations\u003C\u002Fu> (CFR), Part 820.\u003C\u002Fp>\u003Cp>We received a response from Vipul Sheth, VP of Quality, MMS dated June 13, 2024 and additional responses dated July 31, 2024 and September 20, 2024 concerning our investigator’s observations noted on the Form FDA 483 (FDA 483), List of Inspectional Observations, that was issued to your firm. We address this response below, in relation to each of the noted violations. These violations include, but are not limited to, the following:\u003C\u002Fp>\u003Cp>1. Failure to establish and implement procedures for corrective and preventive actions as required by 21 CFR 820.100(a).\u003C\u002Fp>\u003Cp>For example, you were found to have 544 open tickets for software defects of which 111 were categorized as Catastrophic or Severe patient harm. Four (4) were noted to have\u003Cbr>cybersecurity vulnerabilities. Of 256 open tickets for server software issues, 55 for thermal effects were categorized as Catastrophic or Severe. Your CAPA # 8438925 was not found to be complete.\u003C\u002Fp>\u003Cp>The adequacy of your firm’s response cannot be determined at this time.\u003C\u002Fp>\u003Cp>You provided an Issue and Defect Tracking procedure and stated that closure of “Tickets” will be tracked in a risk-prioritized manner by June 30, 2025 and conduct training. You state that you established a quality metric that monitors the timely closure of “Defects” and presented to the FY2024 Q3 Quarterly Management Review meeting to determine the definition of metric. You have not provided the results of the management review. You also stated you will enhance your \u003Cstrong>(b)(4)\u003C\u002Fstrong>. You have not provided evidence of implementation of these corrective actions.\u003C\u002Fp>\u003Cp>2. Failure to establish procedures for receiving, reviewing, and evaluating complaints by a formally designated unit as required by 21 CFR 820.198(a).\u003C\u002Fp>\u003Cp>For example, for 8 complaints [04168007, 04167379, 04170044, 04178943, 04179552, 041686160, 04208805, and 04211537] during the December 2023 to January 2024 time period, for issues with the Pyxis \u003Cstrong>(b)(4)\u003C\u002Fstrong> server, e.g., servers offline at three hospitals and required shutdown, none of the complaints were evaluated for MDR reporting. You stated that MDR reportability is not done for \u003Cstrong>(b)(4)\u003C\u002Fstrong> server complaints because the server is not a medical device, and that the server is not part of the Pyxis system. Your firm provided evidence of a regulatory assessment as \u003Cstrong>(b)(4)\u003C\u002Fstrong> Server Baseline Regulatory Assessment, DIR #10000428322.\u003C\u002Fp>\u003Cp>Your firm uses the \u003Cstrong>(b)(4)\u003C\u002Fstrong> system to document complaints and has a Complaint Handling Procedure. You also have a Complaint Investigation procedure, but you stated you only perform investigations for MDR reportable complaints. In a review of two spreadsheets, Case Notes for Reportable was noted as N\u002FA. Your firm was found to have approximately 92, 083 complaints for delay in delivery of medications due to freezing, shut down, or malfunction including complaints and 70 complaints for wrong medications dispensed, without evidence of investigation. Also, eight (8) complaints reported potential electrical safety issues with the Pyxis MedBank Dispensing Cabinet, however none were investigated.\u003C\u002Fp>\u003Cp>The adequacy of your firm’s response cannot be determined at this time.\u003C\u002Fp>\u003Cp>You stated that complaint investigations were not comprehensive with event details, patient or device information, and components linked to complaints were not always requested to be returned. You state that your \u003Cstrong>(b)(4)\u003C\u002Fstrong> database has limitations in making updates or corrections to Case Notes details. You have not provided evidence of implementation of corrective actions for these deficiencies. In addition, you have not provided supporting evidence of your CAPA 10308384 to enhance complaint handling\u002FMDR procedures or your CAPA to investigate thermal issues with complaints to determine root cause and if CAPAs will be implemented.\u003C\u002Fp>\u003Cp>3. Failure of design validation to include adequate risk analysis as required by 21 CFR 820.30(g).\u003C\u002Fp>\u003Cp>For example, your firm’s System Hazard Analysis for the MedStation ES System failed to take into consideration higher severity risks such as a complaint reporting a patient death possibly due to delay in accessing medications. In addition, since 2022, there have been multiple reports of life-threatening situations involving Pyxis delay in dispensing medications. For example, complaint 3799113 (system stopped responding during cardiac arrest); 4042263 (users tried to remove required medications to prevent patient from drowning but took too long and patient rushed to hospital); 03842764 (system did not dispense Propofol during a procedure, patient woke up during surgery); 4453386 (wrong CUBIE opened causing significant delay during emergency event, unresponsive patient); 3534347 (patient blood clot and Heparin not showing as available); 4059672 (system did not allow users to remove lorazepam for seizure patient); and 3559647 (system stopped during procedure requiring tracheostomy).\u003C\u002Fp>\u003Cp>Your MedBank System Hazard Analysis identifies five electrical hazards with a severity of harm of Critical or Catastrophic. You stated that all Pyxis systems are IEC 60601 compliant except MedBank because MedBank is not intended for patients as it is used in a pharmacy. You produced a certifying organization (UL) email apparently stating MedBank is a medical device but does not fall within the scope of IEC 60601-1. You stated MedBank falls within IEC 61010, Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use and our investigator noted to you that 61001 pertains to laboratory equipment. There were 8 complaints with electrical issues. You did not provide records to demonstrate that the MedBank devices are compliant with the IEC 60601 standard to ensure that electrical safety hazards are mitigated.\u003C\u002Fp>\u003Cp>Your Pyxis MedStation ES Medication Dispensing system applications allow sharing data and communicating with other systems as described in your Product Risk Management Plan BD Pyxis MedStation ES System. In complaint 4420172, it reported the Pyxis CIISAFE ES system opening the wrong doors for medications after all stations were re-installed after a cyber-attack. You acknowledged that threat modeling procedures have been implemented to assess exploitability of cybersecurity vulnerabilities and possible patient harm. You stated that you conducted \u003Cstrong>(b)(4)\u003C\u002Fstrong>. You have not established a process for assessing the exploitability of cybersecurity vulnerabilities and the severity of patient harm if the vulnerability were to be exploited.\u003C\u002Fp>\u003Cp>The adequacy of your firm’s response cannot be determined at this time.\u003C\u002Fp>\u003Cp>You stated that you are taking action through CAPA to ensure risk management files to consider postmarket data. You stated that you have Product Risk Management and Product Risk Management – Released Product procedures but that Product Support Engineers (PSE) are not always included as part of the investigation process. Your Complaint Handling procedure does not require escalation to PSE, and you state that you will enhance the complaint handling and risk management processes. You have not provided evidence of implementation of corrective actions for complaint handling and risk management.\u003C\u002Fp>\u003Cp>For the FDA-cited example, you stated that complaint 2397210 was not escalated but was part of CAPA 3078666 to improve the design history file. You stated that the complaint was considered in the System Hazard Analysis (SHA) from May 7, 2024 but not for what FDA cited, e.g., delayed medication. Per your SHA, the harm severity is Catastrophic. You stated that you have received other complaints to indicate delayed medication hazard and should be Catastrophic. You have not provided evidence of implementation of corrective actions for this harm severity issue.\u003C\u002Fp>\u003Cp>You escalated the threat modeling process and updated security procedures, but it is not evident as to your completion of product security deliverables for the next revision of the Pyxis MedStation ES, review\u002Frevise all product security deliverables for all Dispensing products, and performance of an assessment of the current process to AAMI and FDA guidance documents on cybersecurity to determine whether additional enhancements are required. It is also not evident as to the status of your CAPA 10315457.\u003C\u002Fp>\u003Cp>\u003Cstrong>\u003Cu>Medical Device Reporting (MDR)\u003C\u002Fu>\u003C\u002Fstrong>\u003Cbr>Our inspection revealed that your firm’s Pyxis devices are misbranded under section 502(t)(2) of the Act, 21 U.S.C. § 352(t)(2), in that your firm failed or refused to furnish material or information respecting the device that is required by or under section 519 of the Act, 21 U.S.C. § 360i, and 21 CFR Part 803 – Medical Device Reporting. Significant violations include, but are not limited to, the following:\u003C\u002Fp>\u003Cp>1. Failure to submit a report to the FDA no later than 30 calendar days after the day that your firm received or otherwise became aware of information, from any source, that reasonably suggests that a device that it markets has malfunctioned and this device or a similar device that your firm markets would be likely to cause or contribute to a death or serious injury, if the malfunction were to recur, as required by 21 CFR 803.50(a)(2). For example:\u003C\u002Fp>\u003Cp>&nbsp; a. The information included for Complaint# 02840390 describes an adverse event occurring as the result of malfunction of your firm’s Pyxis MedStation ES System (i.e. unexpected reboot) while in use. The MDR#2016493-2020-00001 received by FDA describes an event where the patient sustained a serious injury resulting from your firm’s same device malfunction. This report establishes precedence that the referenced malfunction would be likely to cause or contribute to a death or serious injury, if it were to recur. There is no information included for the complaint that justifies that the referenced malfunction would not be likely to cause or contribute to a death or serious injury. Your firm became aware of the event on October 25, 2022. However, the corresponding MDR#2016493-2024-00410 was received by FDA on June 11, 2024, which is beyond the required 30 calendar day timeframe.\u003C\u002Fp>\u003Cp>&nbsp; b. The information included for Complaint# 03595420 describes an adverse event occurring as the result of malfunction of your firm’s Pyxis MedStation ES System (i.e. missing patient data) while in use. The MDR#2016493-2022-99102 received by FDA describes an event where the patient expired as a result of the firm’s same malfunction. This report establishes precedence that the referenced malfunction would be likely to cause or contribute to a death or serious injury, if it were to recur. There is no information included for the complaint that justifies that the referenced malfunction would not be likely to cause or contribute to a death or serious injury. Your firm became aware of the event on June 27, 2023. However, the corresponding MDR#2016493-2024-00415 was received by FDA on June 11, 2024, which is beyond the required 30 calendar day timeframe.\u003C\u002Fp>\u003Cp>&nbsp; c. The information included for Complaint# 02653489 reasonably suggests that your firm’s Pyxis MedStation ES System malfunctioned (i.e. drawer inaccessibility) during use. Your firm had previously initiated recall Z-1015-2013 for the same malfunction. Per the Preamble, in the Medical Devices; Medical User Facility and Manufacturer Reporting, Certification and Registration; Final Rule, 60 Fed. Reg. 63585 (Dec. 11, 1995), Comment 12, a malfunction is reportable if the manufacturer takes or would be required to take an action under sections 518 or 519(g) of the act as a result of the malfunction of the device or other similar devices. There is no information in the complaint to rule out that the referenced malfunction would not be likely to cause or contribute to a death or serious injury if it were to recur. Your firm became aware of the event on August 29, 2022. However, the corresponding MDR#2016493-2024-00408 was received by FDA on June 11, 2024, which is beyond the required 30 calendar day timeframe.\u003C\u002Fp>\u003Cp>&nbsp; d. The information provided for Complaint #03500083, #03708861, and #04422892 describes malfunctions (i.e. power failure) of your firm’s Pyxis MedBank ES System emitting smoke or burning smell in a hospital setting. We consider the nature of such an oxygen-enriched environment potentiates the possibly of a fire resulting in a death or serious injury if it were to recur. There is no information in the complaints that justified that these events were not the result of a device malfunction. Your firm became aware of Complaint #03500083 on May 25, 2023, Complaint #03708861 on August 3, 2023, and Complaint #04422892 on March 12, 2024, and FDA received the corresponding MDRs #2016493-2024-00400, #2016493-2024-00401, and #2016493-2024-00404 on June 11, 2024, which exceeds the required 30-calendar-day reporting timeframe.\u003C\u002Fp>\u003Cp>The adequacy of your firm’s responses dated June 13, 2024, July 31, 2024 and September 20, 2024 cannot be determined at this time. In the response, your firm references that it initiated on June 5, 2024, CAPA #10308384 to improve its complaint identification and MDR reporting processes. This includes process and procedural improvements, as well as a transition to its \u003Cstrong>(b)(4)\u003C\u002Fstrong> system for its Pyxis Dispensing products. These are intended to be long-term corrective actions aimed to ensure timely complaint management, MDR assessment, and reporting. Additionally, your firm plans to conduct a retrospective review of complaint records stored in the \u003Cstrong>(b)(4)\u003C\u002Fstrong> electronic tool for cases opened from February 1, 2022 to the present and submit newly identified MDRs. However, your firm has not provided evidence of completing all the planned corrective actions, including the retrospective review of complaint records and staff training.\u003C\u002Fp>\u003Cp>\u003Cstrong>\u003Cu>Corrections and Removals\u003C\u002Fu>\u003C\u002Fstrong>\u003Cbr>Our inspection also revealed that your firm’s Pyxis devices are misbranded under section 502(t)(2) of the Act, 21 U.S.C. § 352(t)(2), in that your firm failed or refused to furnish material or information respecting the device that is required by or under section 519 of the Act, 21 U.S.C. § 360i, and 21 CFR Part 806 – Medical Devices; Reports of Corrections and Removals. Violations include, but are not limited to, the following:\u003C\u002Fp>\u003Cp>1. Failure to submit a Report of Correction or Removal, initiated to remedy a violation which may present a risk to health, within 10 working days of initiating such correction or removal, as required by 21 CFR § 806.10. For example:\u003C\u002Fp>\u003Cp>&nbsp; a. CareFusion issued a Product Advisory, dated 2\u002F14\u002F2023, and a follow-up 1\u002F9\u002F2024, to customers describing three door\u002Fdrawer failure situations, described in MMS-22-4590, MMS-23-4599, and MMS-23-4634. Dispensing system door\u002Fdrawer failure can lead to a delay or inability to dispense medications, which may present a risk to health. This action meets the definition of a medical device correction or removal initiated to remedy a violation which may present a risk to health, for which you are required to submit a Report of Correction or Removal to FDA. As of October 31, 2024, you did not submit a Medical Device Report of Correction or Removal to FDA for this action.\u003C\u002Fp>\u003Cp>&nbsp; b. Your firm issued a \u003Cstrong>(b)(4)\u003C\u002Fstrong>, described in MMS-23-4697, for the MedStation ES system software on 3\u002F17\u002F2023. You issued an Urgent Medical Device Correction, dated 4\u002F5\u002F2023, announcing ES 1.7.4 software updates for Alternate Location Tooltip Error and Upload Data Error. Failure of the alternate location tooltip feature for a multi-item order can contribute to a delay in therapy, which may present a risk to health. This action meets the definition of a medical device correction or removal initiated to remedy a violation which may present a risk to health, for which you are required to submit a Report of Correction or Removal to FDA. As of October 31, 2024, you did not submit a Medical Device Report of Correction or Removal to FDA for this action.\u003C\u002Fp>\u003Cp>c. CareFusion issued Customer Release Notes dated September 2023, describing BD Pyxis MedBank system release software v1.3.4. This update, described in MMS-23-4884, was intended to resolve the MedBank cabinet allowing dispense of a medication requiring RxVerify Validation Code without the validation code being entered. Dispensing without the validation code could lead to removal and\u002For administration of an incorrect dose, or incorrect medication to a patient, which may present a risk to health. This action meets the definition of a medical device correction or removal initiated to remedy a violation which may present a risk to health, for which you are required to submit a Report of Correction or Removal to FDA. As of October 31, 2024, you did not submit a Medical Device Report of Correction or Removal to FDA for this action.\u003C\u002Fp>\u003Cp>Your firm’s response to the FDA-483, dated June 13, 2024, does not address Reports of Corrections or Removals. As of October 31, 2024, you have not submitted Reports of Correction or Removal to FDA for the actions described herein.\u003C\u002Fp>\u003Cp>Your firm should take prompt action to address any violations identified in this letter. Failure to adequately address this matter may result in regulatory action being initiated by the FDA without further notice. These actions include, but are not limited to, seizure, injunction, and civil money penalties.\u003C\u002Fp>\u003Cp>Other federal agencies may take your compliance with the FD&amp;C Act and its implementing regulations into account when considering the award of federal contracts. Additionally, should FDA determine that you have Quality System regulation violations that are reasonably related to premarket approval applications for Class III devices, such devices will not be approved until the violations have been addressed. Should FDA determine that your devices or facilities do not meet the requirements of the Act, requests for Certificates to Foreign Governments (CFG) may not be granted.\u003C\u002Fp>\u003Cp>Please notify this office in writing within fifteen business days from the date you receive this letter of the specific steps your firm has taken to address the noted violations, as well as an explanation of how your firm plans to prevent these violations, or similar violations, from occurring again. Include documentation of the corrections and\u002For corrective actions (which must address systemic problems) that your firm has taken. If your firm’s planned corrections and\u002For corrective actions will occur over time, please include a timetable for implementation of those activities. If corrections and\u002For corrective actions cannot be completed within fifteen business days, state the reason for the delay and the time within which these activities will be completed. Your firm’s response should be comprehensive and address any violations included in this Warning Letter. If you believe that your products are not in violation of the FD&amp;C Act, include your reasoning and any supporting information for our consideration as part of your response.\u003C\u002Fp>\u003Cp>Your firm’s response should be sent to Jeffrey Wooley, Acting Assistant Director at CDRHWarningLetterResponses@fda.hhs.gov. Please include in the subject line, CMS case #691601 when replying. If you have any questions about the contents of this letter, please contact: Raymond W. Brullo, Compliance Officer raymond.brullo@fda.h\u003Ca>hs.gov.\u003C\u002Fa>\u003C\u002Fp>\u003Cp>Finally, you should know that this letter is not intended to be an all-inclusive list of the violations at your firm’s facility. It is your firm’s responsibility to ensure compliance with applicable laws and regulations administered by FDA. The specific violations noted in this letter and in the Inspectional Observations, FDA 483, issued at the close of the inspection may be symptomatic of serious problems in your firm’s manufacturing and quality management systems. Your firm should investigate and determine the causes of any violations and take prompt actions to address any violations and bring the products into compliance.\u003C\u002Fp>\u003Cp>Sincerely yours,\u003Cbr>\u002FS\u002F\u003C\u002Fp>\u003Cp>RDML Sean M. Boyd, MPH, USPHS\u003Cbr>Director\u003Cbr>Office of Regulatory Programs\u003Cbr>Office of Product Evaluation and Quality\u003Cbr>Center for Devices and Radiological Health&nbsp;\u003C\u002Fp>\u003Cp>cc:&nbsp;\u003C\u002Fp>\u003Cp>Connor L. Bates, President, Medication Management Systems at \u003Cstrong>(b)(6)\u003C\u002Fstrong>\u003Cbr>Vipul Sheth, VP of Quality, Medication Management Systems at \u003Cstrong>(b)(6)\u003C\u002Fstrong>\u003C\u002Fp>\n\n\n\n\n\n\n              \n                                            \n              \n            ","Delivery Method:\n\nVia Email\n\nProduct:\n\nMedical Devices\n\nRecipient:\n\nRecipient Name\n\nMr. Thomas E. Polen\n\nRecipient Title\n\nPresident & CEO\n\nBecton, Dickinson, and Company\u002FCareFusion 303, Inc.\n\n1 Becton Drive\n\nFranklin Lakes, NJ 07417\n\nUnited States\n\n(b)(6)\n\nIssuing Office:\n\nCenter for Devices and Radiological Health\n\nUnited States\n\nWARNING LETTER\n11\u002F22\u002F2024\nDear Mr. Polen:\nDuring an inspection of your firm located in San Diego, California on May 6, 2024 through May 22, 2024, an investigator (or investigators) from the United States Food and Drug Administration (FDA) determined that your firm manufactures Pyxis Medication Management System medical devices including, but not limited to, Pyxis MedStation ES, Pyxis ES Anesthesia, and Pyxis MedBank (hereafter also referred to as Pyxis) Under section 201(h) of the Federal Food, Drug, and Cosmetic Act (the Act), 21 U.S.C. § 321(h), these products are devices because they are intended for use in the diagnosis of disease or other conditions or in the cure, mitigation, treatment, or prevention of disease, or to affect the structure or any function of the body.\nQuality System Regulation\nThis inspection revealed that these devices are adulterated within the meaning of section 501(h) of the Act, 21 U.S.C. § 351(h), in that the methods used in, or the facilities or controls used for, their manufacture, packing, storage, or installation are not in conformity with the current good manufacturing practice requirements of the Quality System regulation found at Title 21, Code of Federal Regulations (CFR), Part 820.\nWe received a response from Vipul Sheth, VP of Quality, MMS dated June 13, 2024 and additional responses dated July 31, 2024 and September 20, 2024 concerning our investigator’s observations noted on the Form FDA 483 (FDA 483), List of Inspectional Observations, that was issued to your firm. We address this response below, in relation to each of the noted violations. These violations include, but are not limited to, the following:\n1. Failure to establish and implement procedures for corrective and preventive actions as required by 21 CFR 820.100(a).\nFor example, you were found to have 544 open tickets for software defects of which 111 were categorized as Catastrophic or Severe patient harm. Four (4) were noted to have\ncybersecurity vulnerabilities. Of 256 open tickets for server software issues, 55 for thermal effects were categorized as Catastrophic or Severe. Your CAPA # 8438925 was not found to be complete.\nThe adequacy of your firm’s response cannot be determined at this time.\nYou provided an Issue and Defect Tracking procedure and stated that closure of “Tickets” will be tracked in a risk-prioritized manner by June 30, 2025 and conduct training. You state that you established a quality metric that monitors the timely closure of “Defects” and presented to the FY2024 Q3 Quarterly Management Review meeting to determine the definition of metric. You have not provided the results of the management review. You also stated you will enhance your (b)(4). You have not provided evidence of implementation of these corrective actions.\n2. Failure to establish procedures for receiving, reviewing, and evaluating complaints by a formally designated unit as required by 21 CFR 820.198(a).\nFor example, for 8 complaints [04168007, 04167379, 04170044, 04178943, 04179552, 041686160, 04208805, and 04211537] during the December 2023 to January 2024 time period, for issues with the Pyxis (b)(4) server, e.g., servers offline at three hospitals and required shutdown, none of the complaints were evaluated for MDR reporting. You stated that MDR reportability is not done for (b)(4) server complaints because the server is not a medical device, and that the server is not part of the Pyxis system. Your firm provided evidence of a regulatory assessment as (b)(4) Server Baseline Regulatory Assessment, DIR #10000428322.\nYour firm uses the (b)(4) system to document complaints and has a Complaint Handling Procedure. You also have a Complaint Investigation procedure, but you stated you only perform investigations for MDR reportable complaints. In a review of two spreadsheets, Case Notes for Reportable was noted as N\u002FA. Your firm was found to have approximately 92, 083 complaints for delay in delivery of medications due to freezing, shut down, or malfunction including complaints and 70 complaints for wrong medications dispensed, without evidence of investigation. Also, eight (8) complaints reported potential electrical safety issues with the Pyxis MedBank Dispensing Cabinet, however none were investigated.\nThe adequacy of your firm’s response cannot be determined at this time.\nYou stated that complaint investigations were not comprehensive with event details, patient or device information, and components linked to complaints were not always requested to be returned. You state that your (b)(4) database has limitations in making updates or corrections to Case Notes details. You have not provided evidence of implementation of corrective actions for these deficiencies. In addition, you have not provided supporting evidence of your CAPA 10308384 to enhance complaint handling\u002FMDR procedures or your CAPA to investigate thermal issues with complaints to determine root cause and if CAPAs will be implemented.\n3. Failure of design validation to include adequate risk analysis as required by 21 CFR 820.30(g).\nFor example, your firm’s System Hazard Analysis for the MedStation ES System failed to take into consideration higher severity risks such as a complaint reporting a patient death possibly due to delay in accessing medications. In addition, since 2022, there have been multiple reports of life-threatening situations involving Pyxis delay in dispensing medications. For example, complaint 3799113 (system stopped responding during cardiac arrest); 4042263 (users tried to remove required medications to prevent patient from drowning but took too long and patient rushed to hospital); 03842764 (system did not dispense Propofol during a procedure, patient woke up during surgery); 4453386 (wrong CUBIE opened causing significant delay during emergency event, unresponsive patient); 3534347 (patient blood clot and Heparin not showing as available); 4059672 (system did not allow users to remove lorazepam for seizure patient); and 3559647 (system stopped during procedure requiring tracheostomy).\nYour MedBank System Hazard Analysis identifies five electrical hazards with a severity of harm of Critical or Catastrophic. You stated that all Pyxis systems are IEC 60601 compliant except MedBank because MedBank is not intended for patients as it is used in a pharmacy. You produced a certifying organization (UL) email apparently stating MedBank is a medical device but does not fall within the scope of IEC 60601-1. You stated MedBank falls within IEC 61010, Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use and our investigator noted to you that 61001 pertains to laboratory equipment. There were 8 complaints with electrical issues. You did not provide records to demonstrate that the MedBank devices are compliant with the IEC 60601 standard to ensure that electrical safety hazards are mitigated.\nYour Pyxis MedStation ES Medication Dispensing system applications allow sharing data and communicating with other systems as described in your Product Risk Management Plan BD Pyxis MedStation ES System. In complaint 4420172, it reported the Pyxis CIISAFE ES system opening the wrong doors for medications after all stations were re-installed after a cyber-attack. You acknowledged that threat modeling procedures have been implemented to assess exploitability of cybersecurity vulnerabilities and possible patient harm. You stated that you conducted (b)(4). You have not established a process for assessing the exploitability of cybersecurity vulnerabilities and the severity of patient harm if the vulnerability were to be exploited.\nThe adequacy of your firm’s response cannot be determined at this time.\nYou stated that you are taking action through CAPA to ensure risk management files to consider postmarket data. You stated that you have Product Risk Management and Product Risk Management – Released Product procedures but that Product Support Engineers (PSE) are not always included as part of the investigation process. Your Complaint Handling procedure does not require escalation to PSE, and you state that you will enhance the complaint handling and risk management processes. You have not provided evidence of implementation of corrective actions for complaint handling and risk management.\nFor the FDA-cited example, you stated that complaint 2397210 was not escalated but was part of CAPA 3078666 to improve the design history file. You stated that the complaint was considered in the System Hazard Analysis (SHA) from May 7, 2024 but not for what FDA cited, e.g., delayed medication. Per your SHA, the harm severity is Catastrophic. You stated that you have received other complaints to indicate delayed medication hazard and should be Catastrophic. You have not provided evidence of implementation of corrective actions for this harm severity issue.\nYou escalated the threat modeling process and updated security procedures, but it is not evident as to your completion of product security deliverables for the next revision of the Pyxis MedStation ES, review\u002Frevise all product security deliverables for all Dispensing products, and performance of an assessment of the current process to AAMI and FDA guidance documents on cybersecurity to determine whether additional enhancements are required. It is also not evident as to the status of your CAPA 10315457.\nMedical Device Reporting (MDR)\nOur inspection revealed that your firm’s Pyxis devices are misbranded under section 502(t)(2) of the Act, 21 U.S.C. § 352(t)(2), in that your firm failed or refused to furnish material or information respecting the device that is required by or under section 519 of the Act, 21 U.S.C. § 360i, and 21 CFR Part 803 – Medical Device Reporting. Significant violations include, but are not limited to, the following:\n1. Failure to submit a report to the FDA no later than 30 calendar days after the day that your firm received or otherwise became aware of information, from any source, that reasonably suggests that a device that it markets has malfunctioned and this device or a similar device that your firm markets would be likely to cause or contribute to a death or serious injury, if the malfunction were to recur, as required by 21 CFR 803.50(a)(2). For example:\na. The information included for Complaint# 02840390 describes an adverse event occurring as the result of malfunction of your firm’s Pyxis MedStation ES System (i.e. unexpected reboot) while in use. The MDR#2016493-2020-00001 received by FDA describes an event where the patient sustained a serious injury resulting from your firm’s same device malfunction. This report establishes precedence that the referenced malfunction would be likely to cause or contribute to a death or serious injury, if it were to recur. There is no information included for the complaint that justifies that the referenced malfunction would not be likely to cause or contribute to a death or serious injury. Your firm became aware of the event on October 25, 2022. However, the corresponding MDR#2016493-2024-00410 was received by FDA on June 11, 2024, which is beyond the required 30 calendar day timeframe.\nb. The information included for Complaint# 03595420 describes an adverse event occurring as the result of malfunction of your firm’s Pyxis MedStation ES System (i.e. missing patient data) while in use. The MDR#2016493-2022-99102 received by FDA describes an event where the patient expired as a result of the firm’s same malfunction. This report establishes precedence that the referenced malfunction would be likely to cause or contribute to a death or serious injury, if it were to recur. There is no information included for the complaint that justifies that the referenced malfunction would not be likely to cause or contribute to a death or serious injury. Your firm became aware of the event on June 27, 2023. However, the corresponding MDR#2016493-2024-00415 was received by FDA on June 11, 2024, which is beyond the required 30 calendar day timeframe.\nc. The information included for Complaint# 02653489 reasonably suggests that your firm’s Pyxis MedStation ES System malfunctioned (i.e. drawer inaccessibility) during use. Your firm had previously initiated recall Z-1015-2013 for the same malfunction. Per the Preamble, in the Medical Devices; Medical User Facility and Manufacturer Reporting, Certification and Registration; Final Rule, 60 Fed. Reg. 63585 (Dec. 11, 1995), Comment 12, a malfunction is reportable if the manufacturer takes or would be required to take an action under sections 518 or 519(g) of the act as a result of the malfunction of the device or other similar devices. There is no information in the complaint to rule out that the referenced malfunction would not be likely to cause or contribute to a death or serious injury if it were to recur. Your firm became aware of the event on August 29, 2022. However, the corresponding MDR#2016493-2024-00408 was received by FDA on June 11, 2024, which is beyond the required 30 calendar day timeframe.\nd. The information provided for Complaint #03500083, #03708861, and #04422892 describes malfunctions (i.e. power failure) of your firm’s Pyxis MedBank ES System emitting smoke or burning smell in a hospital setting. We consider the nature of such an oxygen-enriched environment potentiates the possibly of a fire resulting in a death or serious injury if it were to recur. There is no information in the complaints that justified that these events were not the result of a device malfunction. Your firm became aware of Complaint #03500083 on May 25, 2023, Complaint #03708861 on August 3, 2023, and Complaint #04422892 on March 12, 2024, and FDA received the corresponding MDRs #2016493-2024-00400, #2016493-2024-00401, and #2016493-2024-00404 on June 11, 2024, which exceeds the required 30-calendar-day reporting timeframe.\nThe adequacy of your firm’s responses dated June 13, 2024, July 31, 2024 and September 20, 2024 cannot be determined at this time. In the response, your firm references that it initiated on June 5, 2024, CAPA #10308384 to improve its complaint identification and MDR reporting processes. This includes process and procedural improvements, as well as a transition to its (b)(4) system for its Pyxis Dispensing products. These are intended to be long-term corrective actions aimed to ensure timely complaint management, MDR assessment, and reporting. Additionally, your firm plans to conduct a retrospective review of complaint records stored in the (b)(4) electronic tool for cases opened from February 1, 2022 to the present and submit newly identified MDRs. However, your firm has not provided evidence of completing all the planned corrective actions, including the retrospective review of complaint records and staff training.\nCorrections and Removals\nOur inspection also revealed that your firm’s Pyxis devices are misbranded under section 502(t)(2) of the Act, 21 U.S.C. § 352(t)(2), in that your firm failed or refused to furnish material or information respecting the device that is required by or under section 519 of the Act, 21 U.S.C. § 360i, and 21 CFR Part 806 – Medical Devices; Reports of Corrections and Removals. Violations include, but are not limited to, the following:\n1. Failure to submit a Report of Correction or Removal, initiated to remedy a violation which may present a risk to health, within 10 working days of initiating such correction or removal, as required by 21 CFR § 806.10. For example:\na. CareFusion issued a Product Advisory, dated 2\u002F14\u002F2023, and a follow-up 1\u002F9\u002F2024, to customers describing three door\u002Fdrawer failure situations, described in MMS-22-4590, MMS-23-4599, and MMS-23-4634. Dispensing system door\u002Fdrawer failure can lead to a delay or inability to dispense medications, which may present a risk to health. This action meets the definition of a medical device correction or removal initiated to remedy a violation which may present a risk to health, for which you are required to submit a Report of Correction or Removal to FDA. As of October 31, 2024, you did not submit a Medical Device Report of Correction or Removal to FDA for this action.\nb. Your firm issued a (b)(4), described in MMS-23-4697, for the MedStation ES system software on 3\u002F17\u002F2023. You issued an Urgent Medical Device Correction, dated 4\u002F5\u002F2023, announcing ES 1.7.4 software updates for Alternate Location Tooltip Error and Upload Data Error. Failure of the alternate location tooltip feature for a multi-item order can contribute to a delay in therapy, which may present a risk to health. This action meets the definition of a medical device correction or removal initiated to remedy a violation which may present a risk to health, for which you are required to submit a Report of Correction or Removal to FDA. As of October 31, 2024, you did not submit a Medical Device Report of Correction or Removal to FDA for this action.\nc. CareFusion issued Customer Release Notes dated September 2023, describing BD Pyxis MedBank system release software v1.3.4. This update, described in MMS-23-4884, was intended to resolve the MedBank cabinet allowing dispense of a medication requiring RxVerify Validation Code without the validation code being entered. Dispensing without the validation code could lead to removal and\u002For administration of an incorrect dose, or incorrect medication to a patient, which may present a risk to health. This action meets the definition of a medical device correction or removal initiated to remedy a violation which may present a risk to health, for which you are required to submit a Report of Correction or Removal to FDA. As of October 31, 2024, you did not submit a Medical Device Report of Correction or Removal to FDA for this action.\nYour firm’s response to the FDA-483, dated June 13, 2024, does not address Reports of Corrections or Removals. As of October 31, 2024, you have not submitted Reports of Correction or Removal to FDA for the actions described herein.\nYour firm should take prompt action to address any violations identified in this letter. Failure to adequately address this matter may result in regulatory action being initiated by the FDA without further notice. These actions include, but are not limited to, seizure, injunction, and civil money penalties.\nOther federal agencies may take your compliance with the FD&C Act and its implementing regulations into account when considering the award of federal contracts. Additionally, should FDA determine that you have Quality System regulation violations that are reasonably related to premarket approval applications for Class III devices, such devices will not be approved until the violations have been addressed. Should FDA determine that your devices or facilities do not meet the requirements of the Act, requests for Certificates to Foreign Governments (CFG) may not be granted.\nPlease notify this office in writing within fifteen business days from the date you receive this letter of the specific steps your firm has taken to address the noted violations, as well as an explanation of how your firm plans to prevent these violations, or similar violations, from occurring again. Include documentation of the corrections and\u002For corrective actions (which must address systemic problems) that your firm has taken. If your firm’s planned corrections and\u002For corrective actions will occur over time, please include a timetable for implementation of those activities. If corrections and\u002For corrective actions cannot be completed within fifteen business days, state the reason for the delay and the time within which these activities will be completed. Your firm’s response should be comprehensive and address any violations included in this Warning Letter. If you believe that your products are not in violation of the FD&C Act, include your reasoning and any supporting information for our consideration as part of your response.\nYour firm’s response should be sent to Jeffrey Wooley, Acting Assistant Director at CDRHWarningLetterResponses@fda.hhs.gov. Please include in the subject line, CMS case #691601 when replying. If you have any questions about the contents of this letter, please contact: Raymond W. Brullo, Compliance Officer raymond.brullo@fda.hhs.gov.\nFinally, you should know that this letter is not intended to be an all-inclusive list of the violations at your firm’s facility. It is your firm’s responsibility to ensure compliance with applicable laws and regulations administered by FDA. The specific violations noted in this letter and in the Inspectional Observations, FDA 483, issued at the close of the inspection may be symptomatic of serious problems in your firm’s manufacturing and quality management systems. Your firm should investigate and determine the causes of any violations and take prompt actions to address any violations and bring the products into compliance.\nSincerely yours,\n\u002FS\u002F\nRDML Sean M. Boyd, MPH, USPHS\nDirector\nOffice of Regulatory Programs\nOffice of Product Evaluation and Quality\nCenter for Devices and Radiological Health\ncc:\nConnor L. Bates, President, Medication Management Systems at (b)(6)\nVipul Sheth, VP of Quality, Medication Management Systems at (b)(6)","Becton, Dickinson, and Company\u002FCareFusion 303, Inc.","becton-dickinson-and-companycarefusion-303-inc-691601-11222024","2026-08-18T06:42:28.856152+00:00",null,"https:\u002F\u002Fwww.fda.gov\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fbecton-dickinson-and-companycarefusion-303-inc-691601-11222024","2026-10-26T08:08:02.648403+00:00","Warning Letter","Issued","2024-12-17","691601","Medical Devices","Mr. Thomas E. Polen","2026-08-19T17:07:52.992+00:00","Via Email","2024-11-22",{"id":32,"raw":33,"subject":39,"body_html":40,"body_text":41,"firm_name":42,"letter_id":43,"created_at":44,"fei_number":19,"letter_url":45,"updated_at":46,"action_type":22,"case_status":23,"posted_date":47,"marcs_cms_no":48,"product_type":49,"closeout_date":19,"issuing_office":37,"recipient_name":50,"body_fetched_at":51,"delivery_method":52,"recipient_title":19,"reference_number":53,"action_taken_date":54,"medical_device_id":19,"response_letter_date":19},2429,[34,35,36,37,38,13,13,13],"\u003Ctime datetime=\"2022-09-20T13:20:00Z\">09\u002F20\u002F2022\u003C\u002Ftime>\n","\u003Ctime datetime=\"2022-08-23T04:00:00Z\">08\u002F23\u002F2022\u003C\u002Ftime>\n","\u003Ca href=\"\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fbiolab-sciences-inc-621465-08232022\">BioLab Sciences, Inc.\u003C\u002Fa>","Office of Biological Products Operations – Division 2","Deviations\u002FCFR\u002FRegulations for Human Cells, Tissues &amp; Cellular Products (HCT\u002FPs)","Deviations\u002FCFR\u002FRegulations for Human Cells, Tissues & Cellular Products (HCT\u002FPs)","\n\n                            \n                            \n                            \n                            \n                                              \n  \n \n\n                 \n\n  \u003Chr>\n \n\n\u003Cdiv>\n  \u003Cdl>\n\n              \u003Cdt>Delivery Method:\u003C\u002Fdt> \n        \u003Cdd>VIA UNITED PARCEL SERVICE\n                                                                                                                                                                                                                                                                                                                                                                                                                              \u003C\u002Fdd>\n      \n              \u003Cdt>Reference #:\u003C\u002Fdt> \n        \u003Cdd>OBPO 621465\u003C\u002Fdd>\n      \n              \u003Cdt>Product:\u003C\u002Fdt> \n        \u003Cdd>Biologics                          \n            \n            \n            \n            \n            \n            \n            \n             \n            \n            \n            \n              \n            \n            \n            \u003C\u002Fdd>\n      \n          \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n\n\u003Chr>\n\n\u003Cdiv>\n  \u003Cdiv>\n    \u003Cdl>\n\n        \u003Cdt>Recipient:\u003C\u002Fdt>\n\n                      \u003Cdd>\n  \u003Cdiv>\n    \u003Cdiv>Recipient Name\u003C\u002Fdiv>\n              \u003Cdiv>Robert D. Maguire\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n                                \u003Cdd>\n  \u003Cdiv>\n    \u003Cdiv>Recipient Title\u003C\u002Fdiv>\n              \u003Cdiv>President and Chief Executive Officer\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n          \n            \u003Cdd>BioLab Sciences, Inc.\u003C\u002Fdd>\n\n          \n                      \u003Cdd>\u003Cp>\u003Cspan>13825 N. Northsight Blvd., Suite 101\u003C\u002Fspan>\u003Cbr>\n\u003Cspan>Scottsdale\u003C\u002Fspan>, \u003Cspan>AZ\u003C\u002Fspan> \u003Cspan>85260\u003C\u002Fspan>\u003Cbr>\n\u003Cspan>United States\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n          \n          \n          \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n       \u003Cdiv>\n    \u003Cdl>\n          \n          \u003Cdt>Issuing Office:\u003C\u002Fdt>\n        \n         \n          \u003Cdd>Office of Biological Products Operations – Division 2\u003C\u002Fdd>\n        \n         \n          \u003Cdd>\u003Cp>\u003Cspan>United States\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n        \n        \n        \n        \n        \n    \u003C\u002Fdl>\n    \u003Cdl> \n      \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>  \n      \n\u003C\u002Fdiv>\n\n \n\n \n\n\u003Chr>\n\n\u003Cp>\u003Cstrong>WARNING LETTER\u003C\u002Fstrong>\u003C\u002Fp>\n\n\u003Cp>August 23, 2022\u003C\u002Fp>\n\n\u003Cp>Dear Mr. Maguire:\u003C\u002Fp>\n\n\u003Cp>During an inspection of your firm, BioLab Sciences, Inc. (hereinafter, “BioLab Sciences”), located at 7662 E. Gray Rd., Suite 107, Scottsdale, AZ 85260, conducted between August 23, 2021, and September 3, 2021, the United States Food and Drug Administration (FDA) documented that you manufacture products derived from human amniotic fluid, specifically, Fluid GF™, Restore GF™, Fluid Flow™, Amnio Restore™,&nbsp;\u003Cstrong>(b)(4)\u003C\u002Fstrong>, and Stimuleyes™, for allogeneic use, and an epidermal skin tissue product, MyOwnSkin™ and MySkinRestore™, for autologous use (collectively, “your products”).\u003Csup>\u003Cem>\u003Cstrong>1,2\u003C\u002Fstrong>\u003C\u002Fem>\u003C\u002Fsup> You have distributed your products to third-party distributors, some under private label, as well as directly to healthcare professionals throughout the United States. Your amniotic fluid products are intended for injection and are purported to be sterile.\u003C\u002Fp>\n\n\u003Cp>Information and records gathered prior to and during the inspection, including information on your website, www.biolabsciences.com, reflect your products are intended to treat various diseases or conditions. Additionally, information collected indicates your products fit within the definition of a biological product in the Public Health Service Act (PHS Act) [42 U.S.C. 262(i)]. Therefore, your products are drugs as defined in section 201(g) of the Federal Food, Drug, and Cosmetic Act (the FD&amp;C Act) [21 U.S.C. 321(g)] and biological products as defined in section 351(i) of the PHS Act.\u003C\u002Fp>\n\n\u003Cp>MyOwnSkin™ and MySkinRestore™ are also human cells, tissues, or cellular or tissue-based products (HCT\u002FPs) as defined in 21 CFR 1271.3(d) and are subject to regulation under 21 CFR Part 1271, issued under the authority of section 361 of the PHS Act [42 U.S.C. 264]. HCT\u002FPs that do not meet all the criteria in 21 CFR 1271.10(a), and when no exception in 21 CFR 1271.15 applies, are not regulated solely under section 361 of the PHS Act [42 U.S.C. 264] and the regulations in 21 CFR Part 1271. Such products are regulated as drugs, devices, and\u002For biological products under the FD&amp;C Act and\u002For the PHS Act, and are subject to additional regulation, including appropriate premarket review. 21 CFR 1271.20.\u003C\u002Fp>\n\n\u003Cp>Based on a review of materials described above, BioLab Sciences does not qualify for any exception in 21 CFR 1271.15, and MyOwnSkin™ and MySkinRestore™ fail to meet all the criteria in 21 CFR 1271.10(a).\u003C\u002Fp>\n\n\u003Cp>Specifically, MyOwnSkin™ and MySkinRestore™ fail to meet the criterion set forth in 21 CFR 1271.10(a)(1) that they not be more than minimally manipulated as such term is defined for structural tissue in 21 CFR 1271.3(f)(1). Because your processing alters the original relevant characteristics of the skin related to its utility for reconstruction, repair, or replacement, MyOwnSkin™ and MySkinRestore™ are more than minimally manipulated.\u003C\u002Fp>\n\n\u003Cp>MyOwnSkin™ and MySkinRestore™ also fail to meet other criteria set forth in 21 CFR 1271.10(a). An HCT\u002FP meets the criterion in 21 CFR 1271.10(a)(2) if the HCT\u002FP is “intended for homologous use only, as reflected by the labeling, advertising, or other indications of the manufacturer's objective intent.” MyOwnSkin™ and MySkinRestore™ are not intended to perform the same basic function or functions of skin in the recipient as in the donor, such as serving as a protective covering. Rather, these products are intended as advanced wound care therapies, including to regenerate skin in various wounds. Such use is not homologous use as defined in 21 CFR 1271.3(c).\u003C\u002Fp>\n\n\u003Cp>An HCT\u002FP meets the criterion in 21 CFR 1271.10(a)(3) if “the manufacture of the HCT\u002FP does not involve the combination with another article, except for water, crystalloids, or a sterilizing, preserving, or storage agent, provided that the addition of water, crystalloids, or the sterilizing, preserving, or storage agent does not raise new clinical safety concerns with respect to the HCT\u002FP.” Based on the processing and product information available for MyOwnSkin™ and MySkinRestore™, skin cells from a patient’s skin are&nbsp;\u003Cstrong>(b)(4)\u003C\u002Fstrong> prior to shipment and implantation in the same individual. Therefore, this criterion is also not met.\u003C\u002Fp>\n\n\u003Cp>Because Biolab Sciences does not qualify for any exception in 21 CFR 1271.15, and because MyOwnSkin™ and MySkinRestore™ do not meet all the criteria in 21 CFR 1271.10(a), these products are not regulated solely under section 361 of the PHS Act and the regulations in 21 CFR Part 1271. MyOwnSkin™ and MySkinRestore™ appear to be combination products and would be regulated under the statutory authorities applicable to drugs as defined in section 201(g) of the FD&amp;C Act [21 U.S.C. 321(g)] and biological products as defined in section 351(i) of the PHS Act [42 U.S.C. 262(i)].\u003Csup>\u003Cem>\u003Cstrong>3\u003C\u002Fstrong>\u003C\u002Fem>\u003C\u002Fsup>\u003C\u002Fp>\n\n\u003Cp>Please be advised that the definition of HCT\u002FPs in 21 CFR 1271.3(d) excludes secreted or extracted human products. Accordingly, secreted bodily fluids, such as amniotic fluid, are generally not considered HCT\u002FPs subject to regulation under 21 CFR Part 1271. Amniotic fluid intended to treat diseases or conditions in humans is generally regulated as a drug under the FD&amp;C Act and a biological product under the PHS Act and requires premarket review and approval. As such, your products derived from amniotic fluid, Fluid GF™, Restore GF™, Fluid Flow™, Amnio Retore™, Stimuleyes™, and&nbsp;\u003Cstrong>(b)(4)\u003C\u002Fstrong>, are also regulated as drugs and biological products under section 351 of the PHS Act and the FD&amp;C Act.\u003C\u002Fp>\n\n\u003Cp>In order to lawfully market a drug that is a biological product, a valid biologics license must be in effect [42 U.S.C. 262(a)]. Such licenses are issued only after showing that the product is safe, pure, and potent. While in the development stage, such products may be distributed for clinical use in humans only if the sponsor has an investigational new drug application (IND) in effect as specified by FDA regulations [21 U.S.C. 355(i); 42 U.S.C. 262(a)(3); 21 CFR Part 312]. None of your products are the subject of an approved biologics license application (BLA), nor is there an IND in effect for any of them. Based on this information, we have determined that your actions have violated the FD&amp;C Act and the PHS Act.\u003C\u002Fp>\n\n\u003Cp>Additionally, during the inspection, FDA investigators documented evidence of significant deviations from current good manufacturing practice (CGMP) requirements, including deviations from section 501(a)(2)(B) of the FD&amp;C Act and 21 CFR Parts 210 and 211.\u003C\u002Fp>\n\n\u003Cp>At the close of the inspection, the FDA investigators issued a Form FDA-483, List of Inspectional Observations, which described a number of significant CGMP deviations applicable to your products. FDA identified additional significant deviations upon further review of the information collected during the inspection, as described below. Additionally, we have received a safety concern about one of your products.\u003C\u002Fp>\n\n\u003Cp>Your CGMP deficiencies, involving over \u003Cstrong>(b)(4)\u003C\u002Fstrong> units of products manufactured between March 2019 and the present, include, but are not limited to, the following:\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>1. Failure to establish appropriate written procedures designed to prevent microbiological contamination of drug products purporting to be sterile, including procedures for validation of all aseptic and sterilization processes [21 CFR 211.113(b)].\u003C\u002Fstrong> For example:\u003C\u002Fp>\n\n\u003Cp>a. You failed to validate the aseptic processes used to manufacture over&nbsp;\u003Cstrong>(b)(4)\u003C\u002Fstrong> units of Fluid Flow™, Amnio Restore™,\u003Cstrong>(b)(4)\u003C\u002Fstrong>, Stimuleyes™, Fluid GF™, and Restore GF™ (i.e., by performing media fill simulations) since your manufacturing operations began in March 2019. Based on your product labeling, these products purport to be sterile and are expected to be sterile.\u003C\u002Fp>\n\n\u003Cp>b. Your firm failed to validate the sterilization process for Fluid GF™ and Restore GF™. You have manufactured and distributed over \u003Cstrong>(b)(4)\u003C\u002Fstrong> units of these products since June 22, 2021.\u003C\u002Fp>\n\n\u003Cp>c. Your Fluid Flow™ \u003Cstrong>(b)(4)\u003C\u002Fstrong> sterilization validation, entitled “\u003Cstrong>(b)(4)&nbsp;\u003C\u002Fstrong>Sterilization Validation Report,” RST-1052, dated May 20, 2019, is inadequate. For example:\u003C\u002Fp>\n\n\u003Cp>&nbsp; i. You have had failures during your dose verification audit where it was noted that the established dose to achieve sterility was not adequate and for which you made no changes to your process.\u003C\u002Fp>\n\n\u003Cp>&nbsp; ii. You did not assess the impact of the \u003Cstrong>(b)(4)\u003C\u002Fstrong> sterilization on the integrity of the amniotic fluid product’s container-closure system to assure that sterility is maintained.\u003C\u002Fp>\n\n\u003Cp>d. The frequency of monitoring conducted in the critical aseptic areas is insufficient to detect problems and demonstrate control. For example:\u003C\u002Fp>\n\n\u003Cp>&nbsp; i. Surface samples for microbiological monitoring are not collected in the Biological Safety Cabinets (BSCs) directly after processing of your amniotic fluid products. Environmental monitoring should be conducted directly after processing, before cleaning is performed, in order to monitor processing conditions and demonstrate control of the critical area during aseptic processing.\u003C\u002Fp>\n\n\u003Cp>&nbsp; ii. Personnel monitoring is required only every \u003Cstrong>(b)(4)\u003C\u002Fstrong> for personnel who process your amniotic fluid products.\u003C\u002Fp>\n\n\u003Cp>e. In accordance with your cleanroom gowning procedure, personnel performing aseptic processing wear non-sterile personal protective equipment (PPE), such as hair covers, beard covers, and shoe covers, that does not adequately protect against microbiological contamination of your products.\u003C\u002Fp>\n\n\u003Cp>f. During the inspection, FDA investigators observed personnel practices that do not adequately protect against microbiological contamination of your products. For example, operators were observed exiting and entering the cleanroom quickly and frequently during manufacturing operations. This practice potentially disturbs the airflow in the cleanroom environment and could introduce contaminants into the cleanroom.\u003C\u002Fp>\n\n\u003Cp>g. Your written environmental monitoring procedure now describes that \u003Cstrong>(b)(4)\u003C\u002Fstrong> colony forming units (CFUs) is an acceptable result on environmental monitoring plates intended to detect the presence of microorganisms in the critical processing area. This allowance for such high numbers of microorganisms could contribute to product contamination and pose a potentially significant safety concern. For additional information, we recommend that you review FDA Guidance for Industry, Sterile Drug Products Produced by Aseptic Processing – Current Good Manufacturing Practice, available at \u003Ca>www.fda.gov\u002Fdownloads\u002FDrugs\u002FGuidances\u002Fucm070342.pdf\u003C\u002Fa>. FDA’s guidance documents do not establish legal requirements.\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>2. Failure to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity [21 CFR 211.160(b)].\u003C\u002Fstrong> For example, your firm has not established appropriate specifications and test procedures to assure that your amniotic fluid products conform to appropriate standards of identity, strength, quality, and purity. Your finished product testing is limited to a visual examination.\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>3. Failure to establish and follow written procedures for cleaning and maintenance of equipment used in the manufacture, processing, packing, or holding of a drug product [ 21 CFR 211.67(b)].\u003C\u002Fstrong> For example:\u003C\u002Fp>\n\n\u003Cp>a. Your firm failed to validate the cleaning process for your BSCs.\u003Cbr>\n\u003Cbr>\nb. Your firm has not adequately established and followed written procedures for cleaning the \u003Cstrong>(b)(4)\u003C\u002Fstrong> BSCs used to manufacture your products. For example, your written procedure for cleaning does not include the \u003Cstrong>(b)(4)\u003C\u002Fstrong> when \u003Cstrong>(b)(4)\u003C\u002Fstrong> is used to clean the BSCs during \u003Cstrong>(b)(4)\u003C\u002Fstrong> cleanings.\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>4. Failure to establish and follow written procedures describing in sufficient detail the methods and materials used for sanitation [21 CFR 211.56(b)]. \u003C\u002Fstrong>For example:\u003C\u002Fp>\n\n\u003Cp>a. Your firm failed to validate the cleaning process for your cleanrooms.\u003C\u002Fp>\n\n\u003Cp>b. Your firm has not adequately established and followed written procedures for cleaning the cleanrooms used to manufacture your products. For example:\u003C\u002Fp>\n\n\u003Cp>&nbsp; i. In accordance with your cleanroom cleaning procedure, a \u003Cstrong>(b)(4)&nbsp;\u003C\u002Fstrong>cleaning of all contact surfaces in the cleanrooms is required at the&nbsp;\u003Cstrong>(b)(4)\u003C\u002Fstrong> processing operations. However, a review of your \u003Cstrong>(b)(4)\u003C\u002Fstrong> cleaning records revealed that this required cleaning is not always performed, and a justification is not always provided.\u003C\u002Fp>\n\n\u003Cp>&nbsp; ii. You failed to ensure sufficient use of \u003Cstrong>(b)(4)\u003C\u002Fstrong>, a sporicidal agent, in your disinfection program, as required by your cleanroom cleaning procedure. For example, your firm identified \u003Cem>Bacillus\u003C\u002Fem>, species, a spore-forming organism, on your cleanroom floors. You noted that \u003Cstrong>(b)(4)\u003C\u002Fstrong> was not used to disinfect the area because the floors were constructed of materials not normally used in cleanrooms.\u003C\u002Fp>\n\n\u003Cp>&nbsp; iii. Your written procedure for cleanroom cleaning does not include the&nbsp;\u003Cstrong>(b)(4)\u003C\u002Fstrong> when \u003Cstrong>(b)(4)\u003C\u002Fstrong> is used during \u003Cstrong>(b)(4)\u003C\u002Fstrong> cleanings.\u003C\u002Fp>\n\n\u003Cp>&nbsp; iv. The cleaning records do not include dilutions or contact times. During the inspection, no data or rationale for the cleaning agents used or their rotation was provided.\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>5. Your aseptic processing areas are deficiently designed in that the floors are not smooth, hard surfaces that are easily cleanable in order to prevent contamination [21 CFR 211.42(c)(10)(i)].\u003C\u002Fstrong> For example, your cleanrooms floors have seams and gaps rendering them difficult to clean and disinfect.\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>6. Failure to thoroughly investigate any unexplained discrepancy or the failure of a batch or any of its components to meet any of its&nbsp;\u003C\u002Fstrong>\u003Cstrong>specifications whether or not the batch has been already distributed [21 CFR 211.192].\u003C\u002Fstrong> For example, between October 30, 2020, and July 30, 2021, you failed to investigate approximately 90% of your excursions for microbiological monitoring of the cleanroom environment, including two excursions in the critical processing area (i.e., inside your BSCs). While you identified the contaminating organisms, you did not thoroughly investigate the excursions to determine the root cause, product impact, and corrective and preventive actions. Examples of microorganisms identified in your cleanroom include \u003Cem>Bacillus\u003C\u002Fem> species non-anthracis, \u003Cem>Fictibacillus\u003C\u002Fem> species, \u003Cem>Bacillus pumilus\u003C\u002Fem>, Gram Positive Cocci, fungi, and \u003Cem>Bacillus megaterium\u003C\u002Fem>.\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>7. Failure to ensure that each lot of components, drug product containers, and closures are withheld from use until the lot has been sampled, tested, or examined, as appropriate, and released for use by the quality control unit [21 CFR 211.84].\u003C\u002Fstrong> For example:\u003C\u002Fp>\n\n\u003Cp>a. Your firm used \u003Cstrong>(b)(4)\u003C\u002Fstrong> to manufacture approximately \u003Cstrong>(b)(4)\u003C\u002Fstrong> batches of MyOwnSkin™ and MySkinRestore™ between June 27, 2019, and September 24, 2021, even though such components had not been examined and released for use by the quality control unit. These components are labeled for research use only.\u003C\u002Fp>\n\n\u003Cp>b. Your firm used \u003Cstrong>(b)(4)\u003C\u002Fstrong>, to manufacture MyOwnSkin™ and MySkinRestore™, even though such components had not been examined and released for use by the quality control unit. The labeling of those components advises against their use in “Human or Animal Drugs.”\u003C\u002Fp>\n\n\u003Cp>c. Your firm lacks evidence, such as testing, to demonstrate that these components meet all specifications of identity, strength, quality, and purity.\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>8. Failure to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess [21 CFR 211.100(a)].\u003C\u002Fstrong> Specifically, your firm has not validated the manufacturing processes for Fluid GF™, Restore GF™, Fluid Flow™, Amnio Restore™, \u003Cstrong>(b)(4)\u003C\u002Fstrong>, Stimuleyes™, MyOwnSkin™, and MySkinRestore™.\u003C\u002Fp>\n\n\u003Cp>\u003Cstrong>9. Failure to establish and follow a written testing program designed to assess the stability characteristics of drug products and to use the results of such stability testing to determine appropriate storage conditions and expiration dates [21 CFR 211.166(a)].\u003C\u002Fstrong> Specifically, your firm has assigned a twelve-month expiration date to your amniotic fluid products and a 24-hour expiration date to your skin products without supporting data from stability testing.\u003C\u002Fp>\n\n\u003Cp>We have reviewed your written responses, dated September 27, 2021, November 30, 2021, February 14, 2022, March 26, 2022, May 26, 2022, and July 26, 2022, to the inspectional observations on the Form FDA-483, and we have determined that they are inadequate to address our concerns.\u003C\u002Fp>\n\n\u003Cp>We acknowledge your commitment to voluntarily cease the manufacture and distribution of MyOwnSkin™ and MySkinRestore™ until an IND is in effect for such products.\u003Csup>\u003Cem>\u003Cstrong>4\u003C\u002Fstrong>\u003C\u002Fem>\u003C\u002Fsup> You also explain that you currently market amniotic membrane products, Membrane Wrap™ and Membrane Restore™, and amniotic fluid products, Fluid GF™ and Restore GF™, and commit that all other tissue products marketed in the past under additional brand names have been discontinued. Please note that amniotic fluid products are not considered tissue products. We acknowledge that you report having discontinued manufacturing \u003Cstrong>(b)(4)\u003C\u002Fstrong>, Stimuleyes™, Fluid Flow™, and Amnio Restore™.\u003C\u002Fp>\n\n\u003Cp>Your responses, however, do not adequately address your failure to have an IND in effect for your amniotic fluid products and your lack of an approved BLA to lawfully market those products. As noted above, to lawfully market a drug that is a biological product, a valid biologics license must be in effect [42 U.S.C. 262(a)]. Such licenses are issued only after showing that the product is safe, pure, and potent. While in the development stage, such a product may be distributed for clinical use in humans only if the sponsor has an IND in effect, as specified by FDA regulations, that covers such clinical use [21 U.S.C. 355(i); 42 U.S.C. 262(a)(3); 21 CFR Part 312].\u003C\u002Fp>\n\n\u003Cp>Your response also does not adequately address any inventory of Fluid GF™, Fluid Flow™, Restore GF™, and Amnio Restore™ at your facility. In response to this letter, provide your specific plans for the disposition of all of these products. Please also explain in detail your intention to use your inventory of Fluid Flow™ and Amnio Restore™, currently in quarantine, for “potential research use.”\u003C\u002Fp>\n\n\u003Cp>We note that you have previously marketed Amnio Breathe™, a nebulizer bundle containing Fluid Flow™. In response to this letter, please also inform FDA whether you are currently marketing this product or intend to in the future.\u003C\u002Fp>\n\n\u003Cp>Finally, we note that in your responses you discuss updates to your procedures in an attempt to comply with CGMP requirements. We have reviewed those updates and listed your CGMP deficiencies above. We are not providing further input on your updates to procedures in this letter.\u003C\u002Fp>\n\n\u003Cp>Neither this letter nor the observations noted on the Form FDA-483, which were discussed with you at the conclusion of the inspection, are intended to be an all-inclusive list of deficiencies. It is your responsibility to ensure full compliance with the FD&amp;C Act, PHS Act, and all applicable regulations.\u003C\u002Fp>\n\n\u003Cp>This letter notifies you of our findings and provides you an opportunity to address them. Failure to adequately address these matters may lead to regulatory action without further notice. Such actions include seizure and\u002For injunction.\u003C\u002Fp>\n\n\u003Cp>For further information about IND requirements, please contact the Center for Biologics Evaluation and Research (CBER), Division of Regulatory Project Management, Office of Tissues and Advanced Therapies, at (240) 402-8190, or OTATRPMS@fda.hhs.gov. Please include a copy of this letter with your initial submission to CBER.\u003C\u002Fp>\n\n\u003Cp>We request that you respond in writing within fifteen (15) working days from your receipt of this letter, outlining the specific steps you have taken or plan to take to correct the noted violations and prevent their recurrence. Include any documentation necessary to show that matters have been addressed. If you do not believe your products are in violation of the FD&amp;C Act, PHS Act, or applicable regulations, include your reasoning and any supporting information for our consideration. If you cannot address these matters completely within fifteen (15) working days, please explain the reason for your delay and the time frame for completion.\u003C\u002Fp>\n\n\u003Cp>Your response should be sent to the following address: Amy Graf, Compliance Officer, U.S. Food and Drug Administration, Office of Biological Products Operations – Division 2, 300 River Place Dr. – Suite 5900, Detroit, MI 48207 or emailed to Amy.Graf@fda.hhs.gov. If you have any questions, please contact Ms. Graf at (313) 393-2034 or via e-mail.\u003C\u002Fp>\n\n\u003Cp>Sincerely,\u003Cbr>\n\u002FS\u002F\u003C\u002Fp>\n\n\u003Cp>Karlton T. Watson\u003Cbr>\nProgram Division Director\u003Cbr>\nOffice of Biological Products Operations – Division 2\u003C\u002Fp>\n\n\u003Cp>Cc: Robert D. Maguire\u003Cbr>\nPresident and Chief Executive Officer\u003Cbr>\nBioLab Sciences, Inc.\u003Cbr>\n7662 East Gray Road, Suite 107\u003Cbr>\nScottsdale, AZ 85260\u003C\u002Fp>\n\n\u003Cp>_________________________\u003C\u002Fp>\n\n\u003Cp>\u003Cem>\u003Cstrong>1\u003C\u002Fstrong>\u003C\u002Fem> This letter only pertains to Fluid GF™, Restore GF™, Fluid Flow™, Amnio Restore™,&nbsp;\u003Cstrong>(b)(4)\u003C\u002Fstrong>, Stimuleyes™, MyOwnSkin™, and MySkinRestore™. You also manufacture products derived from amniotic membrane, including Membrane Wrap™, Membrane Restore™, and Vision Sphere™. Please be advised that Membrane Wrap™ does not appear to meet the homologous use only criterion at 21 CFR 1271.10(a)(2). You describe this product as a “human tissue allograft derived from amniotic membrane that provides structural tissue for use as a wound and protectant covering.” Use of Membrane Wrap™ as a wound covering would be considered a homologous use. However, you also market this product, for example, to reduce pain and scarring, adhere wounds, heal, and as “anti-bacterial” and for “immune privileged[] and neovascularization.” Such uses are considered nonhomologous uses for amniotic membrane. Membrane Wrap™ must meet all the criteria at 21 CFR 1271.10(a), including the homologous use criterion at 21 CFR 1271.10(a)(2), to be regulated solely under section 361 of the Public Health Service Act and the regulations in 21 CFR Part 1271. This letter does not otherwise address your amniotic membrane products.\u003C\u002Fp>\n\n\u003Cp>\u003Cem>\u003Cstrong>2\u003C\u002Fstrong>\u003C\u002Fem> Some of your products are the same products marketed under different brand names. For example, you represented to FDA that \u003Cstrong>(b)(4)\u003C\u002Fstrong> is the same product as Stimuleyes™. Likewise, MyOwnSkin™ and MySkinRestore™ are the same product marketed under different brand names.\u003C\u002Fp>\n\n\u003Cp>\u003Cem>\u003Cstrong>3\u003C\u002Fstrong>\u003C\u002Fem> As combination products, MyOwnSkin™ and MySkinRestore™ would be appropriately assigned to the Center for Biologics Evaluation and Research (CBER) based on the combination products’ primary mode of action. \u003Cstrong>(b)(4)\u003C\u002Fstrong>.\u003C\u002Fp>\n\n\u003Cp>\u003Cem>\u003Cstrong>4 \u003C\u002Fstrong>\u003C\u002Fem>We note that you had been informed by FDA prior to FDA’s inspection that MyOwnSkin™ appeared to be regulated as a combination product. Nevertheless, you continued to manufacture and distribute this product without premarketing approval until September 24, 2021.\u003C\u002Fp>\n\n\n\n\n\n\n\n              \n                                            \n              \n            ","Delivery Method:\n\nVIA UNITED PARCEL SERVICE\n\nReference #:\n\nOBPO 621465\n\nProduct:\n\nBiologics\n\nRecipient:\n\nRecipient Name\n\nRobert D. Maguire\n\nRecipient Title\n\nPresident and Chief Executive Officer\n\nBioLab Sciences, Inc.\n\n13825 N. Northsight Blvd., Suite 101\n\nScottsdale, AZ 85260\n\nUnited States\n\nIssuing Office:\n\nOffice of Biological Products Operations – Division 2\n\nUnited States\n\nWARNING LETTER\n\nAugust 23, 2022\n\nDear Mr. Maguire:\n\nDuring an inspection of your firm, BioLab Sciences, Inc. (hereinafter, “BioLab Sciences”), located at 7662 E. Gray Rd., Suite 107, Scottsdale, AZ 85260, conducted between August 23, 2021, and September 3, 2021, the United States Food and Drug Administration (FDA) documented that you manufacture products derived from human amniotic fluid, specifically, Fluid GF™, Restore GF™, Fluid Flow™, Amnio Restore™, (b)(4), and Stimuleyes™, for allogeneic use, and an epidermal skin tissue product, MyOwnSkin™ and MySkinRestore™, for autologous use (collectively, “your products”).1,2 You have distributed your products to third-party distributors, some under private label, as well as directly to healthcare professionals throughout the United States. Your amniotic fluid products are intended for injection and are purported to be sterile.\n\nInformation and records gathered prior to and during the inspection, including information on your website, www.biolabsciences.com, reflect your products are intended to treat various diseases or conditions. Additionally, information collected indicates your products fit within the definition of a biological product in the Public Health Service Act (PHS Act) [42 U.S.C. 262(i)]. Therefore, your products are drugs as defined in section 201(g) of the Federal Food, Drug, and Cosmetic Act (the FD&C Act) [21 U.S.C. 321(g)] and biological products as defined in section 351(i) of the PHS Act.\n\nMyOwnSkin™ and MySkinRestore™ are also human cells, tissues, or cellular or tissue-based products (HCT\u002FPs) as defined in 21 CFR 1271.3(d) and are subject to regulation under 21 CFR Part 1271, issued under the authority of section 361 of the PHS Act [42 U.S.C. 264]. HCT\u002FPs that do not meet all the criteria in 21 CFR 1271.10(a), and when no exception in 21 CFR 1271.15 applies, are not regulated solely under section 361 of the PHS Act [42 U.S.C. 264] and the regulations in 21 CFR Part 1271. Such products are regulated as drugs, devices, and\u002For biological products under the FD&C Act and\u002For the PHS Act, and are subject to additional regulation, including appropriate premarket review. 21 CFR 1271.20.\n\nBased on a review of materials described above, BioLab Sciences does not qualify for any exception in 21 CFR 1271.15, and MyOwnSkin™ and MySkinRestore™ fail to meet all the criteria in 21 CFR 1271.10(a).\n\nSpecifically, MyOwnSkin™ and MySkinRestore™ fail to meet the criterion set forth in 21 CFR 1271.10(a)(1) that they not be more than minimally manipulated as such term is defined for structural tissue in 21 CFR 1271.3(f)(1). Because your processing alters the original relevant characteristics of the skin related to its utility for reconstruction, repair, or replacement, MyOwnSkin™ and MySkinRestore™ are more than minimally manipulated.\n\nMyOwnSkin™ and MySkinRestore™ also fail to meet other criteria set forth in 21 CFR 1271.10(a). An HCT\u002FP meets the criterion in 21 CFR 1271.10(a)(2) if the HCT\u002FP is “intended for homologous use only, as reflected by the labeling, advertising, or other indications of the manufacturer's objective intent.” MyOwnSkin™ and MySkinRestore™ are not intended to perform the same basic function or functions of skin in the recipient as in the donor, such as serving as a protective covering. Rather, these products are intended as advanced wound care therapies, including to regenerate skin in various wounds. Such use is not homologous use as defined in 21 CFR 1271.3(c).\n\nAn HCT\u002FP meets the criterion in 21 CFR 1271.10(a)(3) if “the manufacture of the HCT\u002FP does not involve the combination with another article, except for water, crystalloids, or a sterilizing, preserving, or storage agent, provided that the addition of water, crystalloids, or the sterilizing, preserving, or storage agent does not raise new clinical safety concerns with respect to the HCT\u002FP.” Based on the processing and product information available for MyOwnSkin™ and MySkinRestore™, skin cells from a patient’s skin are (b)(4) prior to shipment and implantation in the same individual. Therefore, this criterion is also not met.\n\nBecause Biolab Sciences does not qualify for any exception in 21 CFR 1271.15, and because MyOwnSkin™ and MySkinRestore™ do not meet all the criteria in 21 CFR 1271.10(a), these products are not regulated solely under section 361 of the PHS Act and the regulations in 21 CFR Part 1271. MyOwnSkin™ and MySkinRestore™ appear to be combination products and would be regulated under the statutory authorities applicable to drugs as defined in section 201(g) of the FD&C Act [21 U.S.C. 321(g)] and biological products as defined in section 351(i) of the PHS Act [42 U.S.C. 262(i)].3\n\nPlease be advised that the definition of HCT\u002FPs in 21 CFR 1271.3(d) excludes secreted or extracted human products. Accordingly, secreted bodily fluids, such as amniotic fluid, are generally not considered HCT\u002FPs subject to regulation under 21 CFR Part 1271. Amniotic fluid intended to treat diseases or conditions in humans is generally regulated as a drug under the FD&C Act and a biological product under the PHS Act and requires premarket review and approval. As such, your products derived from amniotic fluid, Fluid GF™, Restore GF™, Fluid Flow™, Amnio Retore™, Stimuleyes™, and (b)(4), are also regulated as drugs and biological products under section 351 of the PHS Act and the FD&C Act.\n\nIn order to lawfully market a drug that is a biological product, a valid biologics license must be in effect [42 U.S.C. 262(a)]. Such licenses are issued only after showing that the product is safe, pure, and potent. While in the development stage, such products may be distributed for clinical use in humans only if the sponsor has an investigational new drug application (IND) in effect as specified by FDA regulations [21 U.S.C. 355(i); 42 U.S.C. 262(a)(3); 21 CFR Part 312]. None of your products are the subject of an approved biologics license application (BLA), nor is there an IND in effect for any of them. Based on this information, we have determined that your actions have violated the FD&C Act and the PHS Act.\n\nAdditionally, during the inspection, FDA investigators documented evidence of significant deviations from current good manufacturing practice (CGMP) requirements, including deviations from section 501(a)(2)(B) of the FD&C Act and 21 CFR Parts 210 and 211.\n\nAt the close of the inspection, the FDA investigators issued a Form FDA-483, List of Inspectional Observations, which described a number of significant CGMP deviations applicable to your products. FDA identified additional significant deviations upon further review of the information collected during the inspection, as described below. Additionally, we have received a safety concern about one of your products.\n\nYour CGMP deficiencies, involving over (b)(4) units of products manufactured between March 2019 and the present, include, but are not limited to, the following:\n\n1. Failure to establish appropriate written procedures designed to prevent microbiological contamination of drug products purporting to be sterile, including procedures for validation of all aseptic and sterilization processes [21 CFR 211.113(b)]. For example:\n\na. You failed to validate the aseptic processes used to manufacture over (b)(4) units of Fluid Flow™, Amnio Restore™,(b)(4), Stimuleyes™, Fluid GF™, and Restore GF™ (i.e., by performing media fill simulations) since your manufacturing operations began in March 2019. Based on your product labeling, these products purport to be sterile and are expected to be sterile.\n\nb. Your firm failed to validate the sterilization process for Fluid GF™ and Restore GF™. You have manufactured and distributed over (b)(4) units of these products since June 22, 2021.\n\nc. Your Fluid Flow™ (b)(4) sterilization validation, entitled “(b)(4) Sterilization Validation Report,” RST-1052, dated May 20, 2019, is inadequate. For example:\n\ni. You have had failures during your dose verification audit where it was noted that the established dose to achieve sterility was not adequate and for which you made no changes to your process.\n\nii. You did not assess the impact of the (b)(4) sterilization on the integrity of the amniotic fluid product’s container-closure system to assure that sterility is maintained.\n\nd. The frequency of monitoring conducted in the critical aseptic areas is insufficient to detect problems and demonstrate control. For example:\n\ni. Surface samples for microbiological monitoring are not collected in the Biological Safety Cabinets (BSCs) directly after processing of your amniotic fluid products. Environmental monitoring should be conducted directly after processing, before cleaning is performed, in order to monitor processing conditions and demonstrate control of the critical area during aseptic processing.\n\nii. Personnel monitoring is required only every (b)(4) for personnel who process your amniotic fluid products.\n\ne. In accordance with your cleanroom gowning procedure, personnel performing aseptic processing wear non-sterile personal protective equipment (PPE), such as hair covers, beard covers, and shoe covers, that does not adequately protect against microbiological contamination of your products.\n\nf. During the inspection, FDA investigators observed personnel practices that do not adequately protect against microbiological contamination of your products. For example, operators were observed exiting and entering the cleanroom quickly and frequently during manufacturing operations. This practice potentially disturbs the airflow in the cleanroom environment and could introduce contaminants into the cleanroom.\n\ng. Your written environmental monitoring procedure now describes that (b)(4) colony forming units (CFUs) is an acceptable result on environmental monitoring plates intended to detect the presence of microorganisms in the critical processing area. This allowance for such high numbers of microorganisms could contribute to product contamination and pose a potentially significant safety concern. For additional information, we recommend that you review FDA Guidance for Industry, Sterile Drug Products Produced by Aseptic Processing – Current Good Manufacturing Practice, available at www.fda.gov\u002Fdownloads\u002FDrugs\u002FGuidances\u002Fucm070342.pdf. FDA’s guidance documents do not establish legal requirements.\n\n2. Failure to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity [21 CFR 211.160(b)]. For example, your firm has not established appropriate specifications and test procedures to assure that your amniotic fluid products conform to appropriate standards of identity, strength, quality, and purity. Your finished product testing is limited to a visual examination.\n\n3. Failure to establish and follow written procedures for cleaning and maintenance of equipment used in the manufacture, processing, packing, or holding of a drug product [ 21 CFR 211.67(b)]. For example:\n\na. Your firm failed to validate the cleaning process for your BSCs.\n\nb. Your firm has not adequately established and followed written procedures for cleaning the (b)(4) BSCs used to manufacture your products. For example, your written procedure for cleaning does not include the (b)(4) when (b)(4) is used to clean the BSCs during (b)(4) cleanings.\n\n4. Failure to establish and follow written procedures describing in sufficient detail the methods and materials used for sanitation [21 CFR 211.56(b)]. For example:\n\na. Your firm failed to validate the cleaning process for your cleanrooms.\n\nb. Your firm has not adequately established and followed written procedures for cleaning the cleanrooms used to manufacture your products. For example:\n\ni. In accordance with your cleanroom cleaning procedure, a (b)(4) cleaning of all contact surfaces in the cleanrooms is required at the (b)(4) processing operations. However, a review of your (b)(4) cleaning records revealed that this required cleaning is not always performed, and a justification is not always provided.\n\nii. You failed to ensure sufficient use of (b)(4), a sporicidal agent, in your disinfection program, as required by your cleanroom cleaning procedure. For example, your firm identified Bacillus, species, a spore-forming organism, on your cleanroom floors. You noted that (b)(4) was not used to disinfect the area because the floors were constructed of materials not normally used in cleanrooms.\n\niii. Your written procedure for cleanroom cleaning does not include the (b)(4) when (b)(4) is used during (b)(4) cleanings.\n\niv. The cleaning records do not include dilutions or contact times. During the inspection, no data or rationale for the cleaning agents used or their rotation was provided.\n\n5. Your aseptic processing areas are deficiently designed in that the floors are not smooth, hard surfaces that are easily cleanable in order to prevent contamination [21 CFR 211.42(c)(10)(i)]. For example, your cleanrooms floors have seams and gaps rendering them difficult to clean and disinfect.\n\n6. Failure to thoroughly investigate any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed [21 CFR 211.192]. For example, between October 30, 2020, and July 30, 2021, you failed to investigate approximately 90% of your excursions for microbiological monitoring of the cleanroom environment, including two excursions in the critical processing area (i.e., inside your BSCs). While you identified the contaminating organisms, you did not thoroughly investigate the excursions to determine the root cause, product impact, and corrective and preventive actions. Examples of microorganisms identified in your cleanroom include Bacillus species non-anthracis, Fictibacillus species, Bacillus pumilus, Gram Positive Cocci, fungi, and Bacillus megaterium.\n\n7. Failure to ensure that each lot of components, drug product containers, and closures are withheld from use until the lot has been sampled, tested, or examined, as appropriate, and released for use by the quality control unit [21 CFR 211.84]. For example:\n\na. Your firm used (b)(4) to manufacture approximately (b)(4) batches of MyOwnSkin™ and MySkinRestore™ between June 27, 2019, and September 24, 2021, even though such components had not been examined and released for use by the quality control unit. These components are labeled for research use only.\n\nb. Your firm used (b)(4), to manufacture MyOwnSkin™ and MySkinRestore™, even though such components had not been examined and released for use by the quality control unit. The labeling of those components advises against their use in “Human or Animal Drugs.”\n\nc. Your firm lacks evidence, such as testing, to demonstrate that these components meet all specifications of identity, strength, quality, and purity.\n\n8. Failure to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess [21 CFR 211.100(a)]. Specifically, your firm has not validated the manufacturing processes for Fluid GF™, Restore GF™, Fluid Flow™, Amnio Restore™, (b)(4), Stimuleyes™, MyOwnSkin™, and MySkinRestore™.\n\n9. Failure to establish and follow a written testing program designed to assess the stability characteristics of drug products and to use the results of such stability testing to determine appropriate storage conditions and expiration dates [21 CFR 211.166(a)]. Specifically, your firm has assigned a twelve-month expiration date to your amniotic fluid products and a 24-hour expiration date to your skin products without supporting data from stability testing.\n\nWe have reviewed your written responses, dated September 27, 2021, November 30, 2021, February 14, 2022, March 26, 2022, May 26, 2022, and July 26, 2022, to the inspectional observations on the Form FDA-483, and we have determined that they are inadequate to address our concerns.\n\nWe acknowledge your commitment to voluntarily cease the manufacture and distribution of MyOwnSkin™ and MySkinRestore™ until an IND is in effect for such products.4 You also explain that you currently market amniotic membrane products, Membrane Wrap™ and Membrane Restore™, and amniotic fluid products, Fluid GF™ and Restore GF™, and commit that all other tissue products marketed in the past under additional brand names have been discontinued. Please note that amniotic fluid products are not considered tissue products. We acknowledge that you report having discontinued manufacturing (b)(4), Stimuleyes™, Fluid Flow™, and Amnio Restore™.\n\nYour responses, however, do not adequately address your failure to have an IND in effect for your amniotic fluid products and your lack of an approved BLA to lawfully market those products. As noted above, to lawfully market a drug that is a biological product, a valid biologics license must be in effect [42 U.S.C. 262(a)]. Such licenses are issued only after showing that the product is safe, pure, and potent. While in the development stage, such a product may be distributed for clinical use in humans only if the sponsor has an IND in effect, as specified by FDA regulations, that covers such clinical use [21 U.S.C. 355(i); 42 U.S.C. 262(a)(3); 21 CFR Part 312].\n\nYour response also does not adequately address any inventory of Fluid GF™, Fluid Flow™, Restore GF™, and Amnio Restore™ at your facility. In response to this letter, provide your specific plans for the disposition of all of these products. Please also explain in detail your intention to use your inventory of Fluid Flow™ and Amnio Restore™, currently in quarantine, for “potential research use.”\n\nWe note that you have previously marketed Amnio Breathe™, a nebulizer bundle containing Fluid Flow™. In response to this letter, please also inform FDA whether you are currently marketing this product or intend to in the future.\n\nFinally, we note that in your responses you discuss updates to your procedures in an attempt to comply with CGMP requirements. We have reviewed those updates and listed your CGMP deficiencies above. We are not providing further input on your updates to procedures in this letter.\n\nNeither this letter nor the observations noted on the Form FDA-483, which were discussed with you at the conclusion of the inspection, are intended to be an all-inclusive list of deficiencies. It is your responsibility to ensure full compliance with the FD&C Act, PHS Act, and all applicable regulations.\n\nThis letter notifies you of our findings and provides you an opportunity to address them. Failure to adequately address these matters may lead to regulatory action without further notice. Such actions include seizure and\u002For injunction.\n\nFor further information about IND requirements, please contact the Center for Biologics Evaluation and Research (CBER), Division of Regulatory Project Management, Office of Tissues and Advanced Therapies, at (240) 402-8190, or OTATRPMS@fda.hhs.gov. Please include a copy of this letter with your initial submission to CBER.\n\nWe request that you respond in writing within fifteen (15) working days from your receipt of this letter, outlining the specific steps you have taken or plan to take to correct the noted violations and prevent their recurrence. Include any documentation necessary to show that matters have been addressed. If you do not believe your products are in violation of the FD&C Act, PHS Act, or applicable regulations, include your reasoning and any supporting information for our consideration. If you cannot address these matters completely within fifteen (15) working days, please explain the reason for your delay and the time frame for completion.\n\nYour response should be sent to the following address: Amy Graf, Compliance Officer, U.S. Food and Drug Administration, Office of Biological Products Operations – Division 2, 300 River Place Dr. – Suite 5900, Detroit, MI 48207 or emailed to Amy.Graf@fda.hhs.gov. If you have any questions, please contact Ms. Graf at (313) 393-2034 or via e-mail.\n\nSincerely,\n\n\u002FS\u002F\n\nKarlton T. Watson\n\nProgram Division Director\n\nOffice of Biological Products Operations – Division 2\n\nCc: Robert D. Maguire\n\nPresident and Chief Executive Officer\n\nBioLab Sciences, Inc.\n\n7662 East Gray Road, Suite 107\n\nScottsdale, AZ 85260\n\n_________________________\n\n1 This letter only pertains to Fluid GF™, Restore GF™, Fluid Flow™, Amnio Restore™, (b)(4), Stimuleyes™, MyOwnSkin™, and MySkinRestore™. You also manufacture products derived from amniotic membrane, including Membrane Wrap™, Membrane Restore™, and Vision Sphere™. Please be advised that Membrane Wrap™ does not appear to meet the homologous use only criterion at 21 CFR 1271.10(a)(2). You describe this product as a “human tissue allograft derived from amniotic membrane that provides structural tissue for use as a wound and protectant covering.” Use of Membrane Wrap™ as a wound covering would be considered a homologous use. However, you also market this product, for example, to reduce pain and scarring, adhere wounds, heal, and as “anti-bacterial” and for “immune privileged[] and neovascularization.” Such uses are considered nonhomologous uses for amniotic membrane. Membrane Wrap™ must meet all the criteria at 21 CFR 1271.10(a), including the homologous use criterion at 21 CFR 1271.10(a)(2), to be regulated solely under section 361 of the Public Health Service Act and the regulations in 21 CFR Part 1271. This letter does not otherwise address your amniotic membrane products.\n\n2 Some of your products are the same products marketed under different brand names. For example, you represented to FDA that (b)(4) is the same product as Stimuleyes™. Likewise, MyOwnSkin™ and MySkinRestore™ are the same product marketed under different brand names.\n\n3 As combination products, MyOwnSkin™ and MySkinRestore™ would be appropriately assigned to the Center for Biologics Evaluation and Research (CBER) based on the combination products’ primary mode of action. (b)(4).\n\n4 We note that you had been informed by FDA prior to FDA’s inspection that MyOwnSkin™ appeared to be regulated as a combination product. Nevertheless, you continued to manufacture and distribute this product without premarketing approval until September 24, 2021.","BioLab Sciences, Inc.","biolab-sciences-inc-621465-08232022","2026-08-18T06:42:29.145918+00:00","https:\u002F\u002Fwww.fda.gov\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fbiolab-sciences-inc-621465-08232022","2026-10-26T08:08:04.986053+00:00","2022-09-20","621465","Biologics","Robert D. Maguire","2026-08-20T01:33:07.944+00:00","VIA UNITED PARCEL SERVICE","OBPO 621465","2022-08-23",2,{"510k":57,"classification":58,"enforcement":59,"event":60,"event_backfill":61,"pma":62,"warning_letter":63},"2026-11-16T02:00:55.89+00:00","2026-11-16T02:00:41.999+00:00","2026-11-16T02:00:49.415+00:00","2026-11-18T04:00:44.748+00:00","2026-09-07T05:17:28.839+00:00","2026-11-16T02:01:03.155+00:00","2026-11-17T01:02:55.859+00:00"]