[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-warning-letter-flowchem-pharma-private-limited-720719-03112026":3,"fda-latest-sync-dates":30},{"id":4,"letter_id":5,"action_type":6,"firm_name":7,"fei_number":8,"issuing_office":9,"subject":10,"posted_date":11,"action_taken_date":12,"response_letter_date":8,"closeout_date":8,"case_status":13,"letter_url":14,"reference_number":15,"marcs_cms_no":16,"product_type":17,"delivery_method":18,"recipient_name":19,"recipient_title":8,"body_html":20,"body_text":21,"body_fetched_at":22,"medical_device_id":8,"raw":23,"created_at":28,"updated_at":29},265,"flowchem-pharma-private-limited-720719-03112026","Warning Letter","Flowchem Pharma Private Limited",null,"Center for Drug Evaluation and Research (CDER)","CGMP\u002FActive Pharmaceutical Ingredient (API)\u002FAdulterated","2026-03-17","2026-03-11","Issued","https:\u002F\u002Fwww.fda.gov\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fflowchem-pharma-private-limited-720719-03112026","320-26-51","720719","Drugs","VIA UPS","Mr. Anjan K. Roy","\n\n                            \n                            \n                            \n                            \n                                              \n  \n \n\n                 \n\n  \u003Chr>\n \n\n\u003Cdiv class=\"inset-column\">\n  \u003Cdl class=\"lcds-description-list--grid\">\n\n              \u003Cdt class=\"cell-1_1\">Delivery Method:\u003C\u002Fdt> \n        \u003Cdd class=\"cell-2_1\">VIA UPS\n                                                                                                                                                                                                                                                                                                                                                                                                                              \u003C\u002Fdd>\n      \n              \u003Cdt class=\"cell-1_2\">Reference #:\u003C\u002Fdt> \n        \u003Cdd class=\"cell-2_2\">320-26-51\u003C\u002Fdd>\n      \n              \u003Cdt class=\"cell-1_3\">Product:\u003C\u002Fdt> \n        \u003Cdd class=\"cell-2_3\">Drugs                          \n            \n            \n            \n            \n            \n            \n            \n             \n            \n            \n            \n              \n            \n            \n            \u003C\u002Fdd>\n      \n          \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n\n\u003Chr>\n\n\u003Cdiv class=\"row inset-column\">\n  \u003Cdiv class=\"col-xs-12 col-md-6\">\n    \u003Cdl class=\"\">\n\n        \u003Cdt>Recipient:\u003C\u002Fdt>\n\n                      \u003Cdd>\n  \u003Cdiv class=\"field field--name-field-recipient-name field--type-string field--label-above\">\n    \u003Cdiv class=\"field--label\">Recipient Name\u003C\u002Fdiv>\n              \u003Cdiv class=\"field--item\">Mr. Anjan K. Roy\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n                                \u003Cdd>\n  \u003Cdiv class=\"field field--name-field-recipient-title field--type-string field--label-above\">\n    \u003Cdiv class=\"field--label\">Recipient Title\u003C\u002Fdiv>\n              \u003Cdiv class=\"field--item\">Managing Director\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n          \n            \u003Cdd>Flowchem Pharma Private Limited\u003C\u002Fdd>\n\n          \n                      \u003Cdd>\u003Cp class=\"address\" translate=\"no\">\u003Cspan class=\"address-line1\">No.: HIG-2000, Ray House\u003C\u002Fspan>\u003Cbr>\n\u003Cspan class=\"address-line2\">Yelahanka New Town\u003C\u002Fspan>\u003Cbr>\n\u003Cspan class=\"locality\">Bengaluru\u003C\u002Fspan> \u003Cspan class=\"postal-code\">560064\u003C\u002Fspan>\u003Cbr>\n\u003Cspan class=\"administrative-area\">Karnataka\u003C\u002Fspan>\u003Cbr>\n\u003Cspan class=\"country\">India\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n          \n          \n          \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n       \u003Cdiv class=\"col-xs-12 col-md-6\">\n    \u003Cdl class=\"\">\n          \n          \u003Cdt>Issuing Office:\u003C\u002Fdt>\n        \n         \n          \u003Cdd>Center for Drug Evaluation and Research (CDER)\u003C\u002Fdd>\n        \n         \n          \u003Cdd>\u003Cp class=\"address\" translate=\"no\">\u003Cspan class=\"country\">United States\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n        \n        \n        \n        \n        \n    \u003C\u002Fdl>\n    \u003Cdl class=\"\"> \n      \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>  \n      \n\u003C\u002Fdiv>\n\n \n\n \n\n\u003Chr>\n\n\u003Cp class=\"text-align-center\">\u003Cstrong>Warning Letter\u003C\u002Fstrong> 320-26-51\u003C\u002Fp>\u003Cp>March 11, 2026\u003C\u002Fp>\u003Cp>Dear Mr. Roy:\u003C\u002Fp>\u003Cp>The United States Food and Drug Administration (FDA) inspected your drug manufacturing facility, Flowchem Pharma Private Limited, FEI 3019853324, at Plot No. 2B-2 &amp; 2C, Survey No. 7(p) &amp; 8(p), Gollapuram Industrial Park, Hindupur Taluk, Andhra Pradesh, from September 8 to 12, 2025.\u003C\u002Fp>\u003Cp>This warning letter summarizes significant deviations from Current Good Manufacturing Practice (CGMP) for active pharmaceutical ingredients (APIs).\u003C\u002Fp>\u003Cp>Because your methods, facilities, or controls for manufacturing, processing, packing, or holding do not conform to CGMP, your APIs are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&amp;C Act), 21 U.S.C. 351(a)(2)(B).\u003C\u002Fp>\u003Cp>We reviewed your September 25, 2025 response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence.\u003C\u002Fp>\u003Cp>During our inspection, our investigators observed specific deviations including, but not limited to, the following.\u003C\u002Fp>\u003Cp>\u003Cstrong>1. Failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the intermediates and API beyond the official or other established specifications.\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>Your firm manufactures \u003Cstrong>(b)(4)\u003C\u002Fstrong> API intended for the U.S. market. You lacked adequate procedures for cleaning and maintenance of manufacturing equipment. FDA documented an unidentified \u003Cstrong>(b)(4)\u003C\u002Fstrong> residue, apparent rust, and unidentified liquids inside or on product contact surfaces of various non-dedicated process equipment used in the production of \u003Cstrong>(b)(4)\u003C\u002Fstrong>. Each was marked as cleaned and ready for use. Additionally, investigators observed discolored and scratched \u003Cstrong>(b)(4)\u003C\u002Fstrong> containers for use in \u003Cstrong>(b)(4)\u003C\u002Fstrong> operations.\u003C\u002Fp>\u003Cp>In your response, you state that you have cleaned equipment and have updated cleaning and maintenance procedures. You also commit to using \u003Cstrong>(b)(4)\u003C\u002Fstrong> storage for \u003Cstrong>(b)(4)\u003C\u002Fstrong>.\u003C\u002Fp>\u003Cp>Your response is inadequate in that it fails to comprehensively address cleaning and maintenance deficiencies or how you will attempt to develop any system to proactively address these issues. Furthermore, you did not perform an assessment of residues and liquids in process equipment that you had identified as clean.\u003C\u002Fp>\u003Cp>Inadequately cleaned and maintained manufacturing equipment can lead to potential cross-contamination that could compromise your API’s quality and safety.\u003C\u002Fp>\u003Cp>In your response to this letter, provide:\u003C\u002Fp>\u003Cul>\u003Cli>Your corrective action and preventive action (CAPA) plan to implement routine, vigilant operations management oversight of facilities and equipment. This plan should ensure, among other things, prompt detection of equipment\u002Ffacilities performance issues, effective execution of repairs, adherence to appropriate preventive maintenance schedules, timely technological upgrades to the equipment\u002Ffacility infrastructure, and improved systems for ongoing management review.\u003C\u002Fli>\u003Cli>A comprehensive, independent retrospective assessment of your cleaning effectiveness to evaluate the scope of cross-contamination hazards. Include the identity of residues, other manufacturing equipment that may have been improperly cleaned, and an assessment whether cross-contaminated products may have been released for distribution. The assessment should identify any inadequacies of cleaning procedures and practices, and encompass each piece of manufacturing equipment used to manufacture more than one product.\u003C\u002Fli>\u003Cli>A CAPA plan, based on the retrospective assessment of your cleaning program, that includes appropriate remediations to your cleaning processes and practices, and timelines for completion. Provide a detailed summary of vulnerabilities in your process for lifecycle management of equipment cleaning. Describe improvements to your cleaning program, including enhancements to cleaning effectiveness; improved ongoing verification of proper cleaning execution for all products and equipment; and all other needed remediations.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>\u003Cstrong>2. Failure to ensure that materials are handled and stored in a manner to prevent degradation, contamination, and cross-contamination.\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>Your firm did not adequately prevent contamination of materials and intermediates. For example, you stored bags of raw materials outside your facility without adequate protection. Our investigators observed multiple bags of material, containing API, that were open and exposed to the environment. These bags were observed adjacent to an area undergoing apparent construction, an activity which may generate airborne dust and debris. Moreover, when your firm prepared a fresh solution of \u003Cstrong>(b)(4)\u003C\u002Fstrong>, our investigators observed that it was visibly contaminated with unidentified brown particulate matter on the surface.\u003C\u002Fp>\u003Cp>Your response states that you have moved the storage location of \u003Cstrong>(b)(4)\u003C\u002Fstrong> and that you have developed a new procedure for preparing \u003Cstrong>(b)(4)\u003C\u002Fstrong> solutions in a \u003Cstrong>(b)(4)\u003C\u002Fstrong>, rather than in open barrels, as observed during the inspection. Your response is inadequate in that your response fails to identify or provide a comprehensive description of the current storage conditions of materials. Moreover, your response fails to comprehensively evaluate your material storage practices. You do not address whether \u003Cstrong>(b)(4)\u003C\u002Fstrong> or any other materials and intermediates remain stored outside without adequate protection. Additionally, your response fails to identify the source of the contamination observed or provide any evidence that improperly stored materials were not adversely affected by their storage conditions.\u003C\u002Fp>\u003Cp>The introduction of undesirable foreign matter into a raw material, intermediate, or API during production may adversely affect API quality. It is essential that API manufacturers take appropriate measures to prevent such contamination.\u003C\u002Fp>\u003Cp>In your response to this letter, provide:\u003C\u002Fp>\u003Cul>\u003Cli>Your CAPA plan to implement routine, vigilant operations management oversight of facilities and equipment. This plan should ensure, among other things, prompt detection of equipment\u002Ffacilities performance issues, effective execution of repairs, adherence to appropriate preventive maintenance schedules, timely technological upgrades to the equipment\u002Ffacility infrastructure, and improved systems for ongoing management review.\u003C\u002Fli>\u003Cli>Your plans to provide sufficient space for the orderly storage of materials and adequate protection from environmental elements.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>\u003Cstrong>3. Failure to establish an impurity profile for identified and unidentified impurities and failure to ensure all test procedures are scientifically sound and appropriate to ensure that your API conform to established standards of quality and purity.\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>You failed to conduct a comprehensive evaluation of your manufacturing processes to identify potential impurities. For example, you did not validate your method for testing for organic impurities in \u003Cstrong>(b)(4)\u003C\u002Fstrong> API, nor did you have a specification for these impurities. Chromatograms from your unvalidated method showed unknown, unintegrated impurities that were not quantified. As a result, these peaks were not fully considered when making your release decisions.\u003C\u002Fp>\u003Cp>Additionally, you failed to determine the suitability of each secondary reference standard against a primary reference standard. For example, you continued to use your 2021 standard for \u003Cstrong>(b)(4)\u003C\u002Fstrong> that was never qualified against an official reference standard.\u003C\u002Fp>\u003Cp>In your response, you state that you manufactured API as per the United States Pharmacopeia (USP) monograph and therefore did not test for impurities. Your response further states that you identified and synthesized potential impurities, and you commit to developing and validating an analytical method for organic impurities. This is unacceptable, as establishing an impurity profile for your API is expected under CGMP. Furthermore, your response is inadequate in that it fails to demonstrate whether released batches will meet your general specification for related substances, particularly given that your retrospective analysis includes up to \u003Cstrong>(b)(4)\u003C\u002Fstrong> unknown impurities.\u003C\u002Fp>\u003Cp>Manufacturers are expected to establish complete impurity profiles for each API as part of the process validation effort. You are responsible for developing and using suitable methods to detect impurities when designing, and making changes to, your manufacturing processes. If you detect new or higher levels of impurities, you should fully evaluate the impurities and take action to ensure the drug is safe for patients.\u003C\u002Fp>\u003Cp>In your response to this letter, provide:\u003C\u002Fp>\u003Cul>\u003Cli>A comprehensive independent assessment of your laboratory practices, procedures, methods, equipment, documentation, and analyst competencies. Based on this review, provide a detailed plan to remediate and evaluate the effectiveness of your laboratory system.\u003C\u002Fli>\u003Cli>A retrospective review of all API lots released without appropriate testing for impurities and how that may impact finished drug quality.\u003C\u002Fli>\u003Cli>A plan to address any product quality or patient safety risks for out-of-specification lots of APIs in U.S. distribution, including recalls.\u003C\u002Fli>\u003Cli>Specifications, including test methods, used to release APIs. Your response should address your capability to detect and quantify a wide array of potential impurities or contaminants.\u003C\u002Fli>\u003Cli>Improved procedures for performing a systemic evaluation for identifying impurities and establishing a control strategy from the process development stages.\u003C\u002Fli>\u003Cli>Risk assessments for the potential presence of impurities in \u003Cstrong>(b)(4)\u003C\u002Fstrong> USP manufactured at your facility. Include your program for ongoing evaluation of impurity profiles for all drugs and starting materials you produce.\u003C\u002Fli>\u003Cli>Identify corrective actions to ensure adequate quality oversight of establishing appropriate impurity and degradant limits for all drugs and starting materials you produce, using well-studied, scientifically based impurity profiles specific to their own manufacturing processes.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>\u003Cstrong>4. Failure to test the identity of each batch of incoming production material and appropriately qualify suppliers to rely upon their Certificate of Analysis.\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>You failed to conduct an identity test on each lot of raw material used in the manufacture of your API. You instead relied on the certificates of analysis (COAs) from your supplier without adequately qualifying them.\u003C\u002Fp>\u003Cp>For example, you accepted \u003Cstrong>(b)(4)\u003C\u002Fstrong> raw material without performing identity testing or performing vendor qualification. Your firm justified this lack of material testing by stating \u003Cstrong>(b)(4)\u003C\u002Fstrong>, which you stored outside your facility in open bags, was “\u003Cstrong>(b)(4)\u003C\u002Fstrong>.” Moreover, you had not established an appropriate procedure for specification requirements of raw materials.\u003C\u002Fp>\u003Cp>Your response discusses qualifying a new vendor for \u003Cstrong>(b)(4)\u003C\u002Fstrong> and develops a new procedure for setting raw material specifications. Your response is inadequate in that it fails to perform a retrospective analysis of materials that you accepted solely based on COAs. It also fails to address your practice of allowing some materials to be accepted based solely on COAs. Without adequate testing, there is no scientific evidence to assure that your raw materials conform to appropriate specifications before release.\u003C\u002Fp>\u003Cp>In your response to this letter provide:\u003C\u002Fp>\u003Cul>\u003Cli>A comprehensive, independent review of your material system, including but not limited to:\u003Cbr>o evaluating all suppliers of materials to determine if they are reliable and appropriately qualified;\u003Cbr>o an assessment of all materials to determine whether they are consistently of acceptable quality;\u003Cbr>o a review to ensure assigned expiration or retest dates are appropriate (supported by data)\u003Cbr>o adequacy of the supplier qualification program, and its selection, qualification, and disqualification provisions.\u003C\u002Fli>\u003Cli>Based on a thorough review, provide a summary of your systems CAPA to remediate the vendor qualification program and prevent use of unsuitable materials.\u003C\u002Fli>\u003Cli>The chemical quality control specifications, and associated justification for these specifications, you use to test and release each incoming lot of material for use in manufacturing.\u003C\u002Fli>\u003Cli>A description of how you will test each material lot for conformity with all appropriate specifications. If you intend to accept any results from your supplier’s COA instead of testing each material lot, specify how you will robustly establish the reliability of your supplier’s results through initial validation as well as periodic re-validation. In addition, include a commitment to always conduct at least one specific identity test for each material where such testing is required.\u003C\u002Fli>\u003Cli>A summary of results obtained from testing all materials to evaluate the reliability of the COA from each material manufacturer. Include your SOP that describes this COA validation program.\u003C\u002Fli>\u003C\u002Ful>\u003Cp>\u003Cstrong>Quality Unit Authority\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>Significant findings in this letter indicate that your quality unit is not fully exercising its authority and\u002For responsibilities. Your firm must provide the quality unit with the appropriate authority and sufficient resources to carry out its responsibilities and consistently ensure drug quality.\u003C\u002Fp>\u003Cp>\u003Cstrong>CGMP Consultant Recommended\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>Based upon the nature of the deviations we identified at your firm, you should engage a consultant qualified to evaluate your operations and to assist your firm in meeting CGMP requirements. The qualified consultant should also perform a comprehensive six-system audit of your entire operation for CGMP compliance and evaluate the completion and efficacy of your corrective actions and preventive actions before you pursue resolution of your firm’s compliance status with FDA.\u003C\u002Fp>\u003Cp>See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https:\u002F\u002Fwww.fda.gov\u002Fmedia\u002F71023\u002Fdownload.\u003C\u002Fp>\u003Cp>Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.\u003C\u002Fp>\u003Cp>\u003Cstrong>Conclusion\u003C\u002Fstrong>\u003C\u002Fp>\u003Cp>The deviations cited in this letter are not intended to be an all-inclusive list of deviations that exist at your facility. You are responsible for investigating and determining the causes of any deviations and for preventing their recurrence or the occurrence of other deviations.\u003C\u002Fp>\u003Cp>FDA placed all drugs and drug products offered for import into the United States from your firm on Import Alert 66-40 on January 22, 2026.\u003C\u002Fp>\u003Cp>Correct any deviations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any deviations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to any deviations.\u003C\u002Fp>\u003Cp>Failure to address any deviations may also result in the FDA continuing to refuse admission of articles manufactured at Flowchem Pharma Private Limited, Plot No. 2B-2 &amp; 2C, Survey No. 7(p) &amp; 8(p), Gollapuram Industrial Park, Hindupur, into the United States under section 801(a)(3) of the FD&amp;C Act, 21 U.S.C. 381(a)(3). Articles under this authority that appear to be adulterated may be detained or refused admission, in that the methods and controls used in their manufacture do not appear to conform to CGMP within the meaning of section 501(a)(2)(B) of the FD&amp;C Act, 21 U.S.C. 351(a)(2)(B).\u003C\u002Fp>\u003Cp>This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any deviations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.\u003C\u002Fp>\u003Cp>Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3019853324 and ATTN: Andrew Haack.\u003C\u002Fp>\u003Cp>Sincerely,\u003Cbr>\u002FS\u002F\u003C\u002Fp>\u003Cp>Francis Godwin\u003Cbr>Director\u003Cbr>Office of Manufacturing Quality\u003Cbr>Office of Compliance\u003Cbr>Center for Drug Evaluation and Research\u003C\u002Fp>\u003Cp>CC:\u003Cbr>Mr. Ravindra V. Kulkarni\u003Cbr>Site Head\u003Cbr>Flowchem Pharma Private Limited\u003Cbr>Plot No. 2B-2 &amp; 2C, Survey No. 7(p) &amp; 8(p), Gollapuram Industrial Park\u003Cbr>Hindupur Taluk, Sri Sathya Sai District, Andhra Pradesh, 515211, India\u003Cbr>r.kulkarni@flowchempharma.com\u003C\u002Fp>\n\n\u003C!--BEGIN QUALTRICS WEBSITE FEEDBACK SNIPPET-->\n\u003C!--BEGIN QUALTRICS WEBSITE FEEDBACK SNIPPET-->\n\n\n\n              \n                                            \n              \n            ","Delivery Method:\n\nVIA UPS\n\nReference #:\n\n320-26-51\n\nProduct:\n\nDrugs\n\nRecipient:\n\nRecipient Name\n\nMr. Anjan K. Roy\n\nRecipient Title\n\nManaging Director\n\nFlowchem Pharma Private Limited\n\nNo.: HIG-2000, Ray House\n\nYelahanka New Town\n\nBengaluru 560064\n\nKarnataka\n\nIndia\n\nIssuing Office:\n\nCenter for Drug Evaluation and Research (CDER)\n\nUnited States\n\nWarning Letter 320-26-51\nMarch 11, 2026\nDear Mr. Roy:\nThe United States Food and Drug Administration (FDA) inspected your drug manufacturing facility, Flowchem Pharma Private Limited, FEI 3019853324, at Plot No. 2B-2 & 2C, Survey No. 7(p) & 8(p), Gollapuram Industrial Park, Hindupur Taluk, Andhra Pradesh, from September 8 to 12, 2025.\nThis warning letter summarizes significant deviations from Current Good Manufacturing Practice (CGMP) for active pharmaceutical ingredients (APIs).\nBecause your methods, facilities, or controls for manufacturing, processing, packing, or holding do not conform to CGMP, your APIs are adulterated within the meaning of section 501(a)(2)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act), 21 U.S.C. 351(a)(2)(B).\nWe reviewed your September 25, 2025 response to our Form FDA 483 in detail and acknowledge receipt of your subsequent correspondence.\nDuring our inspection, our investigators observed specific deviations including, but not limited to, the following.\n1. Failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the intermediates and API beyond the official or other established specifications.\nYour firm manufactures (b)(4) API intended for the U.S. market. You lacked adequate procedures for cleaning and maintenance of manufacturing equipment. FDA documented an unidentified (b)(4) residue, apparent rust, and unidentified liquids inside or on product contact surfaces of various non-dedicated process equipment used in the production of (b)(4). Each was marked as cleaned and ready for use. Additionally, investigators observed discolored and scratched (b)(4) containers for use in (b)(4) operations.\nIn your response, you state that you have cleaned equipment and have updated cleaning and maintenance procedures. You also commit to using (b)(4) storage for (b)(4).\nYour response is inadequate in that it fails to comprehensively address cleaning and maintenance deficiencies or how you will attempt to develop any system to proactively address these issues. Furthermore, you did not perform an assessment of residues and liquids in process equipment that you had identified as clean.\nInadequately cleaned and maintained manufacturing equipment can lead to potential cross-contamination that could compromise your API’s quality and safety.\nIn your response to this letter, provide:\nYour corrective action and preventive action (CAPA) plan to implement routine, vigilant operations management oversight of facilities and equipment. This plan should ensure, among other things, prompt detection of equipment\u002Ffacilities performance issues, effective execution of repairs, adherence to appropriate preventive maintenance schedules, timely technological upgrades to the equipment\u002Ffacility infrastructure, and improved systems for ongoing management review.\nA comprehensive, independent retrospective assessment of your cleaning effectiveness to evaluate the scope of cross-contamination hazards. Include the identity of residues, other manufacturing equipment that may have been improperly cleaned, and an assessment whether cross-contaminated products may have been released for distribution. The assessment should identify any inadequacies of cleaning procedures and practices, and encompass each piece of manufacturing equipment used to manufacture more than one product.\nA CAPA plan, based on the retrospective assessment of your cleaning program, that includes appropriate remediations to your cleaning processes and practices, and timelines for completion. Provide a detailed summary of vulnerabilities in your process for lifecycle management of equipment cleaning. Describe improvements to your cleaning program, including enhancements to cleaning effectiveness; improved ongoing verification of proper cleaning execution for all products and equipment; and all other needed remediations.\n2. Failure to ensure that materials are handled and stored in a manner to prevent degradation, contamination, and cross-contamination.\nYour firm did not adequately prevent contamination of materials and intermediates. For example, you stored bags of raw materials outside your facility without adequate protection. Our investigators observed multiple bags of material, containing API, that were open and exposed to the environment. These bags were observed adjacent to an area undergoing apparent construction, an activity which may generate airborne dust and debris. Moreover, when your firm prepared a fresh solution of (b)(4), our investigators observed that it was visibly contaminated with unidentified brown particulate matter on the surface.\nYour response states that you have moved the storage location of (b)(4) and that you have developed a new procedure for preparing (b)(4) solutions in a (b)(4), rather than in open barrels, as observed during the inspection. Your response is inadequate in that your response fails to identify or provide a comprehensive description of the current storage conditions of materials. Moreover, your response fails to comprehensively evaluate your material storage practices. You do not address whether (b)(4) or any other materials and intermediates remain stored outside without adequate protection. Additionally, your response fails to identify the source of the contamination observed or provide any evidence that improperly stored materials were not adversely affected by their storage conditions.\nThe introduction of undesirable foreign matter into a raw material, intermediate, or API during production may adversely affect API quality. It is essential that API manufacturers take appropriate measures to prevent such contamination.\nIn your response to this letter, provide:\nYour CAPA plan to implement routine, vigilant operations management oversight of facilities and equipment. This plan should ensure, among other things, prompt detection of equipment\u002Ffacilities performance issues, effective execution of repairs, adherence to appropriate preventive maintenance schedules, timely technological upgrades to the equipment\u002Ffacility infrastructure, and improved systems for ongoing management review.\nYour plans to provide sufficient space for the orderly storage of materials and adequate protection from environmental elements.\n3. Failure to establish an impurity profile for identified and unidentified impurities and failure to ensure all test procedures are scientifically sound and appropriate to ensure that your API conform to established standards of quality and purity.\nYou failed to conduct a comprehensive evaluation of your manufacturing processes to identify potential impurities. For example, you did not validate your method for testing for organic impurities in (b)(4) API, nor did you have a specification for these impurities. Chromatograms from your unvalidated method showed unknown, unintegrated impurities that were not quantified. As a result, these peaks were not fully considered when making your release decisions.\nAdditionally, you failed to determine the suitability of each secondary reference standard against a primary reference standard. For example, you continued to use your 2021 standard for (b)(4) that was never qualified against an official reference standard.\nIn your response, you state that you manufactured API as per the United States Pharmacopeia (USP) monograph and therefore did not test for impurities. Your response further states that you identified and synthesized potential impurities, and you commit to developing and validating an analytical method for organic impurities. This is unacceptable, as establishing an impurity profile for your API is expected under CGMP. Furthermore, your response is inadequate in that it fails to demonstrate whether released batches will meet your general specification for related substances, particularly given that your retrospective analysis includes up to (b)(4) unknown impurities.\nManufacturers are expected to establish complete impurity profiles for each API as part of the process validation effort. You are responsible for developing and using suitable methods to detect impurities when designing, and making changes to, your manufacturing processes. If you detect new or higher levels of impurities, you should fully evaluate the impurities and take action to ensure the drug is safe for patients.\nIn your response to this letter, provide:\nA comprehensive independent assessment of your laboratory practices, procedures, methods, equipment, documentation, and analyst competencies. Based on this review, provide a detailed plan to remediate and evaluate the effectiveness of your laboratory system.\nA retrospective review of all API lots released without appropriate testing for impurities and how that may impact finished drug quality.\nA plan to address any product quality or patient safety risks for out-of-specification lots of APIs in U.S. distribution, including recalls.\nSpecifications, including test methods, used to release APIs. Your response should address your capability to detect and quantify a wide array of potential impurities or contaminants.\nImproved procedures for performing a systemic evaluation for identifying impurities and establishing a control strategy from the process development stages.\nRisk assessments for the potential presence of impurities in (b)(4) USP manufactured at your facility. Include your program for ongoing evaluation of impurity profiles for all drugs and starting materials you produce.\nIdentify corrective actions to ensure adequate quality oversight of establishing appropriate impurity and degradant limits for all drugs and starting materials you produce, using well-studied, scientifically based impurity profiles specific to their own manufacturing processes.\n4. Failure to test the identity of each batch of incoming production material and appropriately qualify suppliers to rely upon their Certificate of Analysis.\nYou failed to conduct an identity test on each lot of raw material used in the manufacture of your API. You instead relied on the certificates of analysis (COAs) from your supplier without adequately qualifying them.\nFor example, you accepted (b)(4) raw material without performing identity testing or performing vendor qualification. Your firm justified this lack of material testing by stating (b)(4), which you stored outside your facility in open bags, was “(b)(4).” Moreover, you had not established an appropriate procedure for specification requirements of raw materials.\nYour response discusses qualifying a new vendor for (b)(4) and develops a new procedure for setting raw material specifications. Your response is inadequate in that it fails to perform a retrospective analysis of materials that you accepted solely based on COAs. It also fails to address your practice of allowing some materials to be accepted based solely on COAs. Without adequate testing, there is no scientific evidence to assure that your raw materials conform to appropriate specifications before release.\nIn your response to this letter provide:\nA comprehensive, independent review of your material system, including but not limited to:\no evaluating all suppliers of materials to determine if they are reliable and appropriately qualified;\no an assessment of all materials to determine whether they are consistently of acceptable quality;\no a review to ensure assigned expiration or retest dates are appropriate (supported by data)\no adequacy of the supplier qualification program, and its selection, qualification, and disqualification provisions.\nBased on a thorough review, provide a summary of your systems CAPA to remediate the vendor qualification program and prevent use of unsuitable materials.\nThe chemical quality control specifications, and associated justification for these specifications, you use to test and release each incoming lot of material for use in manufacturing.\nA description of how you will test each material lot for conformity with all appropriate specifications. If you intend to accept any results from your supplier’s COA instead of testing each material lot, specify how you will robustly establish the reliability of your supplier’s results through initial validation as well as periodic re-validation. In addition, include a commitment to always conduct at least one specific identity test for each material where such testing is required.\nA summary of results obtained from testing all materials to evaluate the reliability of the COA from each material manufacturer. Include your SOP that describes this COA validation program.\nQuality Unit Authority\nSignificant findings in this letter indicate that your quality unit is not fully exercising its authority and\u002For responsibilities. Your firm must provide the quality unit with the appropriate authority and sufficient resources to carry out its responsibilities and consistently ensure drug quality.\nCGMP Consultant Recommended\nBased upon the nature of the deviations we identified at your firm, you should engage a consultant qualified to evaluate your operations and to assist your firm in meeting CGMP requirements. The qualified consultant should also perform a comprehensive six-system audit of your entire operation for CGMP compliance and evaluate the completion and efficacy of your corrective actions and preventive actions before you pursue resolution of your firm’s compliance status with FDA.\nSee FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https:\u002F\u002Fwww.fda.gov\u002Fmedia\u002F71023\u002Fdownload.\nYour use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.\nConclusion\nThe deviations cited in this letter are not intended to be an all-inclusive list of deviations that exist at your facility. You are responsible for investigating and determining the causes of any deviations and for preventing their recurrence or the occurrence of other deviations.\nFDA placed all drugs and drug products offered for import into the United States from your firm on Import Alert 66-40 on January 22, 2026.\nCorrect any deviations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any deviations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to any deviations.\nFailure to address any deviations may also result in the FDA continuing to refuse admission of articles manufactured at Flowchem Pharma Private Limited, Plot No. 2B-2 & 2C, Survey No. 7(p) & 8(p), Gollapuram Industrial Park, Hindupur, into the United States under section 801(a)(3) of the FD&C Act, 21 U.S.C. 381(a)(3). Articles under this authority that appear to be adulterated may be detained or refused admission, in that the methods and controls used in their manufacture do not appear to conform to CGMP within the meaning of section 501(a)(2)(B) of the FD&C Act, 21 U.S.C. 351(a)(2)(B).\nThis letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any deviations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.\nSend your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI 3019853324 and ATTN: Andrew Haack.\nSincerely,\n\u002FS\u002F\nFrancis Godwin\nDirector\nOffice of Manufacturing Quality\nOffice of Compliance\nCenter for Drug Evaluation and Research\nCC:\nMr. Ravindra V. Kulkarni\nSite Head\nFlowchem Pharma Private Limited\nPlot No. 2B-2 & 2C, Survey No. 7(p) & 8(p), Gollapuram Industrial Park\nHindupur Taluk, Sri Sathya Sai District, Andhra Pradesh, 515211, India\nr.kulkarni@flowchempharma.com","2026-08-19T04:50:54.571+00:00",[24,25,26,9,10,27,27,27],"\u003Ctime datetime=\"2026-03-17T04:00:00Z\">03\u002F17\u002F2026\u003C\u002Ftime>\n","\u003Ctime datetime=\"2026-03-11T04:00:00Z\">03\u002F11\u002F2026\u003C\u002Ftime>\n","\u003Ca href=\"\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fflowchem-pharma-private-limited-720719-03112026\">Flowchem Pharma Private Limited\u003C\u002Fa>","","2026-08-18T06:42:28.498414+00:00","2026-08-20T02:24:55.726997+00:00",{"510k":31,"classification":32,"enforcement":33,"event":34,"pma":35,"warning_letter":36},"2026-08-18T06:35:18.347+00:00","2026-08-18T05:52:53.75+00:00","2026-08-18T08:01:54.918+00:00","2026-08-19T02:58:35.995+00:00","2026-08-18T06:36:30.549+00:00","2026-08-20T03:28:02.95+00:00"]