[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-warning-letter-shenzhen-sunell-technology-corporation-613563-03042021":3,"fda-latest-sync-dates":29},{"id":4,"letter_id":5,"action_type":6,"firm_name":7,"fei_number":8,"issuing_office":9,"subject":10,"posted_date":11,"action_taken_date":11,"response_letter_date":8,"closeout_date":12,"case_status":13,"letter_url":14,"reference_number":8,"marcs_cms_no":15,"product_type":16,"delivery_method":8,"recipient_name":17,"recipient_title":8,"body_html":18,"body_text":19,"body_fetched_at":20,"medical_device_id":8,"raw":21,"created_at":27,"updated_at":28},3488,"shenzhen-sunell-technology-corporation-613563-03042021","Warning Letter","Shenzhen Sunell Technology Corporation",null,"Center for Devices and Radiological Health","Adulterated and Misbranded Products Related to Coronavirus Disease 2019 (COVID-19)","2021-03-04","2023-07-27","Closed Out","https:\u002F\u002Fwww.fda.gov\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fshenzhen-sunell-technology-corporation-613563-03042021","613563","Medical Devices","Ann Wu","\n\n                            \n                            \n                            \n                            \n                                              \n  \n \n\n                 \n\n \n\n\u003Cdiv class=\"inset-column\">\n  \u003Cdl class=\"lcds-description-list--grid\">\n\n      \n      \n              \u003Cdt class=\"cell-1_3\">Product:\u003C\u002Fdt> \n        \u003Cdd class=\"cell-2_3\">Medical Devices                          \n            \n            \n            \n            \n            \n            \n            \n             \n            \n            \n            \n              \n            \n            \n            \u003C\u002Fdd>\n      \n          \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n\n\u003Chr>\n\n\u003Cdiv class=\"row inset-column\">\n  \u003Cdiv class=\"col-xs-12 col-md-6\">\n    \u003Cdl class=\"\">\n\n        \u003Cdt>Recipient:\u003C\u002Fdt>\n\n                      \u003Cdd>\n  \u003Cdiv class=\"field field--name-field-recipient-name field--type-string field--label-above\">\n    \u003Cdiv class=\"field--label\">Recipient Name\u003C\u002Fdiv>\n              \u003Cdiv class=\"field--item\">Ann Wu\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n                    \n            \u003Cdd>Shenzhen Sunell Technology Corporation\u003C\u002Fdd>\n\n          \n                      \u003Cdd>\u003Cp class=\"address\" translate=\"no\">\u003Cspan class=\"address-line1\">4 Aerospace Micromoto Bldg 2 Floor 5\u003C\u002Fspan>\u003Cbr>\n\u003Cspan class=\"locality\">Shenzhen\u003C\u002Fspan>\u003Cbr>\n\u003Cspan class=\"country\">China\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n          \n          \n          \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n       \u003Cdiv class=\"col-xs-12 col-md-6\">\n    \u003Cdl class=\"\">\n          \n          \u003Cdt>Issuing Office:\u003C\u002Fdt>\n        \n         \n          \u003Cdd>Center for Devices and Radiological Health\u003C\u002Fdd>\n        \n         \n          \u003Cdd>\u003Cp class=\"address\" translate=\"no\">\u003Cspan class=\"country\">United States\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n        \n        \n        \n        \n        \n    \u003C\u002Fdl>\n    \u003Cdl class=\"\"> \n      \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>  \n      \n\u003C\u002Fdiv>\n\n \n\n \n\n\u003Chr>\n\n\u003Cp>Ann Wu\u003Cbr>\nShenzhen Sunell Technology Corporation\u003Cbr>\nAliases: Sunell Technology, Sunell Security\u003Cbr>\n4 Aerospace Micromoto Bldg 2 Floor 5\u003Cbr>\nShenzhen\u003Cbr>\nCHINA\u003C\u002Fp>\n\n\u003Cp>sales@sunellsecurity.com, support@sunellsecurity.com\u003Cbr>\n&nbsp;&nbsp;\u003Cbr>\nRE:&nbsp;&nbsp;&nbsp;&nbsp; Adulterated and Misbranded Products Related to Coronavirus Disease 2019 (COVID-19)\u003C\u002Fp>\n\n\u003Cp>Dear Sirs,\u003C\u002Fp>\n\n\u003Cp>This is to advise you that the United States Food and Drug Administration (FDA) reviewed your website at the Internet address https:\u002F\u002Fwww.sunellsecurity.com\u002F on February 26, 2021. The FDA has observed that your website offers products for measuring human body temperature, specifically the Bi-Spectrum Fever Screening Network Camera (SN-T5P-F), Temperature Screening Thermographic Network Bullet Camera (SN-F22-B), AI Fever Screening Network Camera With Integrated Blackbody (SN-T5H-P-F), and Fever Screening Body Temperature Measurement Network Camera Accurate ±0.3℃ (SN-T5\u002FF) (collectively, “Screening Cameras”), for sale in the United States. Based on our review, these products are intended to mitigate, prevent, treat, diagnose or cure COVID-19&nbsp; in people, and thus are devices under section 201(h) of the Federal, Food, Drug, and Cosmetic Act (the “Act”), 21 U.S.C. § 321(h).\u003C\u002Fp>\n\n\u003Cp>FDA’s review of your website revealed the following statements that establish that the Screening Cameras are intended for the mitigation, prevention, treatment, diagnosis, or cure of COVID-19, including:\u003C\u002Fp>\n\n\u003Cp>•&nbsp;“At the start-up of 2020, Covid-19 had been sweeping through the mainland of China, and now is getting threatening worldwide. From the occurrence of the epidemic to today, Sunell's ''panda camera'' -- Body Temperature Measurement System played an important role in the work of prevention and control of epidemic. It has become the guardians for thousands of prevention and control site and points worldwide.” and “FIGHTING CORONAVIRUS WE ARE AT THE FRONTIER!” [Both statements published in their article, “History of Sunell Body Temperature Measurement System”, https:\u002F\u002Fwww.sunellsecurity.com\u002Fhistory-of-sunell-body-temperature-measurement-system_n231]\u003C\u002Fp>\n\n\u003Cp>The Screening Cameras are offered for sale in the United States without marketing approval, clearance, or authorization from FDA.&nbsp; Accordingly, your products are adulterated under section 501(f)(1)(B) of the Act, 21 U.S.C. § 351(f)(1)(B), because your firm does not have approved applications for premarket approval (PMA) in effect pursuant to section 515(a) of the Act, 21 U.S.C. § 360e(a), or approved applications for an investigational device exemption (IDE) under section 520(g) of the Act, 21 U.S.C. § 360j(g). Your products are also misbranded under section 502(o) the Act, 21 U.S.C. § 352(o), because your firm did not notify the agency of its intent to introduce these products into interstate commerce for commercial distribution as required by section 510(k) of the Act, 21 U.S.C. § 360(k). The introduction or delivery for introduction of these products into interstate commerce is prohibited under section 301(a) of the Act, 21 U.S.C. § 331(a).\u003C\u002Fp>\n\n\u003Cp>There is currently a global outbreak of respiratory disease caused by a novel coronavirus that has been named “severe acute respiratory syndrome coronavirus 2” (SARS-CoV-2). The disease caused by the virus has been named “Coronavirus Disease 2019” (COVID-19). On January 31, 2020, the Department of Health and Human Services (HHS) issued a declaration of a public health emergency related to COVID-19 and mobilized the Operating Divisions of HHS.[ ] In addition, on March 13, 2020, the President declared a national emergency in response to COVID-19.[ ] Therefore, FDA is taking urgent measures to protect consumers from certain products that, without approval, clearance, or authorization by FDA, claim to mitigate, prevent, treat, diagnose, or cure COVID-19 in people. As described herein, you offer for sale products that are intended for use in the mitigation, prevention, treatment, diagnosis, or cure of COVID-19 in people. We request that you take immediate action to cease the sale of such adulterated and misbranded products for the mitigation, prevention, treatment, diagnosis, or cure of COVID-19.&nbsp;\u003C\u002Fp>\n\n\u003Cp>Use of telethermographic devices for the assessment of human body temperature can present potentially serious public health risks. Such risks may include, but are not limited to, the device incorrectly detecting a normal human body temperature when a person has an elevated temperature and incorrectly assessing a person to have an elevated body temperature when they do not. A person with an undetected elevated temperature who was subject to temperature assessment using a telethermographic device may, as a result, be less likely to adhere to infection prevention and control guidelines, such as social distancing and using personal protective equipment.&nbsp; These risks are more likely to be present where telethermographic devices scan multiple individuals simultaneously. Your website, https:\u002F\u002Fwww.sunellsecurity.com\u002F, includes statements that the Screening Cameras are intended to scan multiple individuals simultaneously, including:\u003C\u002Fp>\n\n\u003Cp>•&nbsp;“High efficiency on temperature detection, up to 45 Targets” and “Temperature screening for multiple people at the same time” [Both statements published on your Bi-Spectrum Fever Screening Network Camera webpage, https:\u002F\u002Fwww.sunellsecurity.com\u002Fbi-spectrum-fever-screening-network-camera_p16.html]\u003C\u002Fp>\n\n\u003Cp>•&nbsp;“Body temperature measurement up to 30 Targets”, “High efficiency on temperature detection, up to 30Targets”, and “Temperature screening for multiple people at the same time” [All statements published on your Temperature Screening Thermographic Network Bullet Camera webpage, https:\u002F\u002Fwww.sunellsecurity.com\u002Ftemperature-screening-thermographic-network-bullet-camera_p144.html]\u003C\u002Fp>\n\n\u003Cp>•&nbsp;“Body temperature measurement up to 45 Targets”, “High efficiency on temperature detection, up to 45 Targets”, and “Temperature screening for multiple people at the same time” [All statements published on your AI Fever Screening Network Camera With Integrated Blackbody webpage, https:\u002F\u002Fwww.sunellsecurity.com\u002Fai-fever-screening-network-camera-with-integrated-blackbody_p141.html]\u003C\u002Fp>\n\n\u003Cp>•&nbsp;“Body temperature measurement up to 45 Targets”, “High efficiency on temperature detection, up to 45 Targets”, and “Temperature screening for multiple people at the same time” [All statements published on your Fever Screening Body Temperature Measurement Network Camera Accurate ±0.3℃ webpage, https:\u002F\u002Fwww.sunellsecurity.com\u002Ffever-screening-body-temperature-measurement-network-camera-accurate-0-3_p13.html]\u003C\u002Fp>\n\n\u003Cp>For more information about FDA’s regulation of devices used to mitigate, prevent, treat, diagnose, or cure COVID-19; frequently asked questions; and other helpful resources, visit our website at https:\u002F\u002Fwww.fda.gov\u002Fmedical-devices\u002Femergency-situations-medical-devices\u002Fcoronavirus-covid-19-and-medical-devices. In addition, the guidance titled “Enforcement Policy for Telethermographic Systems During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency”[ ] provides information about FDA’s policies intended to help expand the availability of telethermographic systems used for body temperature measurements for triage use during the COVID-19 public health emergency.\u003C\u002Fp>\n\n\u003Cp>You should take action to address the violations cited in this letter. This letter is not meant to be an all-inclusive list of violations that exist in connection with your products or operations. It is your responsibility to ensure that the products you sell are in compliance with the Act and its implementing regulations. We advise you to review your websites, product labels, and other labeling and promotional materials to ensure that you are not misleadingly representing your products as safe and\u002For effective for a COVID-19-related use for which they have not been approved, cleared, or authorized by FDA and that you do not make claims that misbrand the products in violation of the Act. \u003Cstrong>Within 48 hours, please send an email to \u003C\u002Fstrong>COVID-19-Task-Force-CDRH@fda.hhs.gov describing the specific steps you have taken to address these violations, using CMS # 613563 as reference. Include an explanation of each step being taken to prevent the recurrence of any violations, as well as copies of related documentation. Failure to adequately address any violations may result in legal action, including, without limitation, seizure and injunction.&nbsp;\u003C\u002Fp>\n\n\u003Cp>FDA is advising consumers not to purchase or use certain products that have not been approved, cleared, or authorized by FDA and are being misleadingly represented as safe and\u002For effective for the mitigation, prevention, treatment, diagnosis, or cure of COVID-19. Your firm will be added to a published list on FDA's website of firms and websites that have received warning letters from FDA concerning the sale or distribution of COVID-19 related products in violation of the Act. This list can be found at https:\u002F\u002Fwww.fda.gov\u002Fconsumers\u002Fhealth-fraud-scams\u002Ffraudulent-coronavirus-disease-2019-covid-19-products. Once you have taken actions to address the sale of unapproved, uncleared, and unauthorized products for the mitigation, prevention, treatment, diagnosis, or cure of COVID-19, and any appropriate corrective actions have been confirmed by the FDA, the published list will be updated to indicate that your firm has taken such corrective action.\u003C\u002Fp>\n\n\u003Cp>This letter notifies you of our concerns and provides you with an opportunity to address them. If you cannot take action to address this matter completely within 48 hours, state the reason for the delay and the time within which you will do so. If you believe that your product is not in violation of the Act, include your reasoning and any supporting information for our consideration.\u003C\u002Fp>\n\n\u003Cp>If you are not located in the United States, please note that products that appear to be adulterated or misbranded are subject to detention and refusal of admission if they are offered for importation into the United States. We may advise the appropriate regulatory officials in the country from which you operate that FDA considers your products listed above to be adulterated and misbranded products that cannot be legally sold to consumers in the United States.&nbsp;\u003C\u002Fp>\n\n\u003Cp>Please direct any inquiries to FDA at \u003Ca href=\"mailto:COVID-19-Task-Force-CDRH@fda.hhs.gov\">COVID-19-Task-Force-CDRH@fda.hhs.gov\u003C\u002Fa>.&nbsp;\u003C\u002Fp>\n\n\u003Cp>\u003Cbr>\nSincerely,\u003Cbr>\n\u002FS\u002F&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;\u003Cbr>\nCourtney H. Lias, Ph.D.\u003Cbr>\nActing Office Director\u003Cbr>\nOHT3: Office of GastroRenal, ObGyn,\u003Cbr>\n&nbsp;&nbsp;&nbsp; General Hospital and Urology Devices\u003Cbr>\nOffice of Product Evaluation and Quality\u003Cbr>\nCenter for Devices and Radiological Health\u003C\u002Fp>\n\n\n\u003C!--BEGIN QUALTRICS WEBSITE FEEDBACK SNIPPET-->\n\u003C!--BEGIN QUALTRICS WEBSITE FEEDBACK SNIPPET-->\n\n\n\n              \n                                            \n              \n            ","Product:\n\nMedical Devices\n\nRecipient:\n\nRecipient Name\n\nAnn Wu\n\nShenzhen Sunell Technology Corporation\n\n4 Aerospace Micromoto Bldg 2 Floor 5\n\nShenzhen\n\nChina\n\nIssuing Office:\n\nCenter for Devices and Radiological Health\n\nUnited States\n\nAnn Wu\n\nShenzhen Sunell Technology Corporation\n\nAliases: Sunell Technology, Sunell Security\n\n4 Aerospace Micromoto Bldg 2 Floor 5\n\nShenzhen\n\nCHINA\n\nsales@sunellsecurity.com, support@sunellsecurity.com\n\nRE: Adulterated and Misbranded Products Related to Coronavirus Disease 2019 (COVID-19)\n\nDear Sirs,\n\nThis is to advise you that the United States Food and Drug Administration (FDA) reviewed your website at the Internet address https:\u002F\u002Fwww.sunellsecurity.com\u002F on February 26, 2021. The FDA has observed that your website offers products for measuring human body temperature, specifically the Bi-Spectrum Fever Screening Network Camera (SN-T5P-F), Temperature Screening Thermographic Network Bullet Camera (SN-F22-B), AI Fever Screening Network Camera With Integrated Blackbody (SN-T5H-P-F), and Fever Screening Body Temperature Measurement Network Camera Accurate ±0.3℃ (SN-T5\u002FF) (collectively, “Screening Cameras”), for sale in the United States. Based on our review, these products are intended to mitigate, prevent, treat, diagnose or cure COVID-19 in people, and thus are devices under section 201(h) of the Federal, Food, Drug, and Cosmetic Act (the “Act”), 21 U.S.C. § 321(h).\n\nFDA’s review of your website revealed the following statements that establish that the Screening Cameras are intended for the mitigation, prevention, treatment, diagnosis, or cure of COVID-19, including:\n\n• “At the start-up of 2020, Covid-19 had been sweeping through the mainland of China, and now is getting threatening worldwide. From the occurrence of the epidemic to today, Sunell's ''panda camera'' -- Body Temperature Measurement System played an important role in the work of prevention and control of epidemic. It has become the guardians for thousands of prevention and control site and points worldwide.” and “FIGHTING CORONAVIRUS WE ARE AT THE FRONTIER!” [Both statements published in their article, “History of Sunell Body Temperature Measurement System”, https:\u002F\u002Fwww.sunellsecurity.com\u002Fhistory-of-sunell-body-temperature-measurement-system_n231]\n\nThe Screening Cameras are offered for sale in the United States without marketing approval, clearance, or authorization from FDA. Accordingly, your products are adulterated under section 501(f)(1)(B) of the Act, 21 U.S.C. § 351(f)(1)(B), because your firm does not have approved applications for premarket approval (PMA) in effect pursuant to section 515(a) of the Act, 21 U.S.C. § 360e(a), or approved applications for an investigational device exemption (IDE) under section 520(g) of the Act, 21 U.S.C. § 360j(g). Your products are also misbranded under section 502(o) the Act, 21 U.S.C. § 352(o), because your firm did not notify the agency of its intent to introduce these products into interstate commerce for commercial distribution as required by section 510(k) of the Act, 21 U.S.C. § 360(k). The introduction or delivery for introduction of these products into interstate commerce is prohibited under section 301(a) of the Act, 21 U.S.C. § 331(a).\n\nThere is currently a global outbreak of respiratory disease caused by a novel coronavirus that has been named “severe acute respiratory syndrome coronavirus 2” (SARS-CoV-2). The disease caused by the virus has been named “Coronavirus Disease 2019” (COVID-19). On January 31, 2020, the Department of Health and Human Services (HHS) issued a declaration of a public health emergency related to COVID-19 and mobilized the Operating Divisions of HHS.[ ] In addition, on March 13, 2020, the President declared a national emergency in response to COVID-19.[ ] Therefore, FDA is taking urgent measures to protect consumers from certain products that, without approval, clearance, or authorization by FDA, claim to mitigate, prevent, treat, diagnose, or cure COVID-19 in people. As described herein, you offer for sale products that are intended for use in the mitigation, prevention, treatment, diagnosis, or cure of COVID-19 in people. We request that you take immediate action to cease the sale of such adulterated and misbranded products for the mitigation, prevention, treatment, diagnosis, or cure of COVID-19.\n\nUse of telethermographic devices for the assessment of human body temperature can present potentially serious public health risks. Such risks may include, but are not limited to, the device incorrectly detecting a normal human body temperature when a person has an elevated temperature and incorrectly assessing a person to have an elevated body temperature when they do not. A person with an undetected elevated temperature who was subject to temperature assessment using a telethermographic device may, as a result, be less likely to adhere to infection prevention and control guidelines, such as social distancing and using personal protective equipment. These risks are more likely to be present where telethermographic devices scan multiple individuals simultaneously. Your website, https:\u002F\u002Fwww.sunellsecurity.com\u002F, includes statements that the Screening Cameras are intended to scan multiple individuals simultaneously, including:\n\n• “High efficiency on temperature detection, up to 45 Targets” and “Temperature screening for multiple people at the same time” [Both statements published on your Bi-Spectrum Fever Screening Network Camera webpage, https:\u002F\u002Fwww.sunellsecurity.com\u002Fbi-spectrum-fever-screening-network-camera_p16.html]\n\n• “Body temperature measurement up to 30 Targets”, “High efficiency on temperature detection, up to 30Targets”, and “Temperature screening for multiple people at the same time” [All statements published on your Temperature Screening Thermographic Network Bullet Camera webpage, https:\u002F\u002Fwww.sunellsecurity.com\u002Ftemperature-screening-thermographic-network-bullet-camera_p144.html]\n\n• “Body temperature measurement up to 45 Targets”, “High efficiency on temperature detection, up to 45 Targets”, and “Temperature screening for multiple people at the same time” [All statements published on your AI Fever Screening Network Camera With Integrated Blackbody webpage, https:\u002F\u002Fwww.sunellsecurity.com\u002Fai-fever-screening-network-camera-with-integrated-blackbody_p141.html]\n\n• “Body temperature measurement up to 45 Targets”, “High efficiency on temperature detection, up to 45 Targets”, and “Temperature screening for multiple people at the same time” [All statements published on your Fever Screening Body Temperature Measurement Network Camera Accurate ±0.3℃ webpage, https:\u002F\u002Fwww.sunellsecurity.com\u002Ffever-screening-body-temperature-measurement-network-camera-accurate-0-3_p13.html]\n\nFor more information about FDA’s regulation of devices used to mitigate, prevent, treat, diagnose, or cure COVID-19; frequently asked questions; and other helpful resources, visit our website at https:\u002F\u002Fwww.fda.gov\u002Fmedical-devices\u002Femergency-situations-medical-devices\u002Fcoronavirus-covid-19-and-medical-devices. In addition, the guidance titled “Enforcement Policy for Telethermographic Systems During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency”[ ] provides information about FDA’s policies intended to help expand the availability of telethermographic systems used for body temperature measurements for triage use during the COVID-19 public health emergency.\n\nYou should take action to address the violations cited in this letter. This letter is not meant to be an all-inclusive list of violations that exist in connection with your products or operations. It is your responsibility to ensure that the products you sell are in compliance with the Act and its implementing regulations. We advise you to review your websites, product labels, and other labeling and promotional materials to ensure that you are not misleadingly representing your products as safe and\u002For effective for a COVID-19-related use for which they have not been approved, cleared, or authorized by FDA and that you do not make claims that misbrand the products in violation of the Act. Within 48 hours, please send an email to COVID-19-Task-Force-CDRH@fda.hhs.gov describing the specific steps you have taken to address these violations, using CMS # 613563 as reference. Include an explanation of each step being taken to prevent the recurrence of any violations, as well as copies of related documentation. Failure to adequately address any violations may result in legal action, including, without limitation, seizure and injunction.\n\nFDA is advising consumers not to purchase or use certain products that have not been approved, cleared, or authorized by FDA and are being misleadingly represented as safe and\u002For effective for the mitigation, prevention, treatment, diagnosis, or cure of COVID-19. Your firm will be added to a published list on FDA's website of firms and websites that have received warning letters from FDA concerning the sale or distribution of COVID-19 related products in violation of the Act. This list can be found at https:\u002F\u002Fwww.fda.gov\u002Fconsumers\u002Fhealth-fraud-scams\u002Ffraudulent-coronavirus-disease-2019-covid-19-products. Once you have taken actions to address the sale of unapproved, uncleared, and unauthorized products for the mitigation, prevention, treatment, diagnosis, or cure of COVID-19, and any appropriate corrective actions have been confirmed by the FDA, the published list will be updated to indicate that your firm has taken such corrective action.\n\nThis letter notifies you of our concerns and provides you with an opportunity to address them. If you cannot take action to address this matter completely within 48 hours, state the reason for the delay and the time within which you will do so. If you believe that your product is not in violation of the Act, include your reasoning and any supporting information for our consideration.\n\nIf you are not located in the United States, please note that products that appear to be adulterated or misbranded are subject to detention and refusal of admission if they are offered for importation into the United States. We may advise the appropriate regulatory officials in the country from which you operate that FDA considers your products listed above to be adulterated and misbranded products that cannot be legally sold to consumers in the United States.\n\nPlease direct any inquiries to FDA at COVID-19-Task-Force-CDRH@fda.hhs.gov.\n\nSincerely,\n\n\u002FS\u002F\n\nCourtney H. Lias, Ph.D.\n\nActing Office Director\n\nOHT3: Office of GastroRenal, ObGyn,\n\nGeneral Hospital and Urology Devices\n\nOffice of Product Evaluation and Quality\n\nCenter for Devices and Radiological Health","2026-08-20T03:19:25.621+00:00",[22,23,24,9,10,25,26,25],"\u003Ctime datetime=\"2021-03-04T21:30:00Z\">03\u002F04\u002F2021\u003C\u002Ftime>\n","\u003Ctime datetime=\"2021-03-04T05:00:00Z\">03\u002F04\u002F2021\u003C\u002Ftime>\n","\u003Ca href=\"\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fshenzhen-sunell-technology-corporation-613563-03042021\">Shenzhen Sunell Technology Corporation\u003C\u002Fa>","","\u003Ca href=\"\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fshenzhen-sunell-technology-corporation-613563-07202023\">\u003Ctime datetime=\"2023-07-27T04:00:00Z\">07\u002F27\u002F2023\u003C\u002Ftime>\n\u003C\u002Fa>","2026-08-18T06:42:29.386127+00:00","2026-08-20T03:19:27.719869+00:00",{"510k":30,"classification":31,"enforcement":32,"event":33,"pma":34,"warning_letter":35},"2026-08-18T06:35:18.347+00:00","2026-08-18T05:52:53.75+00:00","2026-08-18T08:01:54.918+00:00","2026-08-19T02:58:35.995+00:00","2026-08-18T06:36:30.549+00:00","2026-08-20T03:28:02.95+00:00"]