[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"fda-warning-letter-vlazar-costa-caribe-sa-635746-08152022":3,"fda-latest-sync-dates":29},{"id":4,"letter_id":5,"action_type":6,"firm_name":7,"fei_number":8,"issuing_office":9,"subject":10,"posted_date":11,"action_taken_date":12,"response_letter_date":8,"closeout_date":8,"case_status":13,"letter_url":14,"reference_number":8,"marcs_cms_no":15,"product_type":16,"delivery_method":17,"recipient_name":18,"recipient_title":8,"body_html":19,"body_text":20,"body_fetched_at":21,"medical_device_id":8,"raw":22,"created_at":27,"updated_at":28},2441,"vlazar-costa-caribe-sa-635746-08152022","Warning Letter","Vlazar Costa Caribe S.A.",null,"Center for Food Safety and Applied Nutrition (CFSAN)","Seafood HACCP\u002FCGMP for Foods\u002FAdulterated\u002FInsanitary Conditions","2022-09-13","2022-08-15","Issued","https:\u002F\u002Fwww.fda.gov\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fvlazar-costa-caribe-sa-635746-08152022","635746","Food & Beverages","Via Express Delivery","Mr. Vladimir Suarez Ocampo","\n\n                            \n                            \n                            \n                            \n                                              \n  \n \n\n                 \n\n  \u003Chr>\n \n\n\u003Cdiv class=\"inset-column\">\n  \u003Cdl class=\"lcds-description-list--grid\">\n\n              \u003Cdt class=\"cell-1_1\">Delivery Method:\u003C\u002Fdt> \n        \u003Cdd class=\"cell-2_1\">Via Express Delivery\n                                                                                                                                                                                                                                                                                                                                                                                                                              \u003C\u002Fdd>\n      \n      \n              \u003Cdt class=\"cell-1_3\">Product:\u003C\u002Fdt> \n        \u003Cdd class=\"cell-2_3\">Food &amp; Beverages                          \n            \n            \n            \n            \n            \n            \n            \n             \n            \n            \n            \n              \n            \n            \n            \u003C\u002Fdd>\n      \n          \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n\n\u003Chr>\n\n\u003Cdiv class=\"row inset-column\">\n  \u003Cdiv class=\"col-xs-12 col-md-6\">\n    \u003Cdl class=\"\">\n\n        \u003Cdt>Recipient:\u003C\u002Fdt>\n\n                      \u003Cdd>\n  \u003Cdiv class=\"field field--name-field-recipient-name field--type-string field--label-above\">\n    \u003Cdiv class=\"field--label\">Recipient Name\u003C\u002Fdiv>\n              \u003Cdiv class=\"field--item\">Mr. Vladimir Suarez Ocampo\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n                                \u003Cdd>\n  \u003Cdiv class=\"field field--name-field-recipient-title field--type-string field--label-above\">\n    \u003Cdiv class=\"field--label\">Recipient Title\u003C\u002Fdiv>\n              \u003Cdiv class=\"field--item\">Co-Owner and General Manager\u003C\u002Fdiv>\n          \u003C\u002Fdiv>\n\u003C\u002Fdd>\n          \n            \u003Cdd>Vlazar Costa Caribe S.A.\u003C\u002Fdd>\n\n          \n                      \u003Cdd>\u003Cp class=\"address\" translate=\"no\">\u003Cspan class=\"address-line1\">Barrio Spanish Town Contiguo\u003C\u002Fspan>\u003Cbr>\n\u003Cspan class=\"address-line2\">Iglesia Morava Santa Trinidad\u003C\u002Fspan>\u003Cbr>\n\u003Cspan class=\"locality\">Puerto Cabezas\u003C\u002Fspan>,\u003Cbr>\n\u003Cspan class=\"country\">Nicaragua\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n          \n          \n          \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>            \n\n       \u003Cdiv class=\"col-xs-12 col-md-6\">\n    \u003Cdl class=\"\">\n          \n          \u003Cdt>Issuing Office:\u003C\u002Fdt>\n        \n         \n          \u003Cdd>Center for Food Safety and Applied Nutrition (CFSAN)\u003C\u002Fdd>\n        \n         \n          \u003Cdd>\u003Cp class=\"address\" translate=\"no\">\u003Cspan class=\"country\">United States\u003C\u002Fspan>\u003C\u002Fp>\u003C\u002Fdd>\n        \n        \n        \n        \n        \n    \u003C\u002Fdl>\n    \u003Cdl class=\"\"> \n      \n    \u003C\u002Fdl>\n  \u003C\u002Fdiv>  \n      \n\u003C\u002Fdiv>\n\n \n\n \n\n\u003Chr>\n\n\u003Cp>August 15, 2022\u003C\u002Fp>\n\n\u003Cp class=\"text-align-center\">\u003Cstrong>WARNING LETTER\u003C\u002Fstrong>\u003C\u002Fp>\n\n\u003Cp class=\"text-align-center\">Reference #635746\u003C\u002Fp>\n\n\u003Cp>Dear Mr. Vladimir Suarez Ocampo:\u003C\u002Fp>\n\n\u003Cp>The United States Food and Drug Administration (FDA) conducted a Foreign Remote Regulatory Assessment (FRRA) of your seafood processing facility, Vlazar Costa Caribe S.A., located at Barrio Spanish Town Contiguo Iglesia Morava Santa Trinidad Puerto Cabezas, Nicaragua on April 26 – 29, 2022. During the remote assessment, we found that you had serious violations of the seafood Hazard Analysis and Critical Control Point (HACCP) regulation, Title 21, Code of Federal Regulations (21CFR Part 123). At the conclusion of the assessment, the FDA investigator discussed items of concern. To date, your firm has not responded to the discussion items identified during the FFRA.\u003C\u002Fp>\n\n\u003Cp>In accordance with 21 CFR 123.6(g), failure of a processor of fish or fishery products to have and implement a HACCP plan that complies with this section or otherwise operate in accordance with the requirements of Part 123, renders the fish or fishery products adulterated within the meaning of section 402(a)(4) of the Federal Food, Drug, and Cosmetic Act (the Act), 21 U.S.C. § 342(a)(4). Accordingly, your dried sea cucumber products are adulterated, in that they have been prepared, packed, or held under conditions whereby they may have been rendered injurious to health. You may find the Act, the seafood HACCP regulation, and the 4th Edition of the Fish and Fisheries Products Hazards &amp; Controls Guidance (the Hazards Guide) through links in FDA's home page at www.fda.gov.\u003C\u002Fp>\n\n\u003Cp>Your significant deviations are as follows:\u003C\u002Fp>\n\n\u003Cp>You must conduct a hazard analysis to determine whether there are food safety hazards that are reasonably likely to occur and have a HACCP plan that, at a minimum, lists the critical control points, to comply with 21 CFR 123.6(a) and (c)(2). A critical control point is defined in 21 CFR 123.3(b) as a “point, step, or procedure in a food process at which control can be applied and a food safety hazard can as a result be prevented, eliminated, or reduced to acceptable levels.” However, your firm’s HACCP plan (Version 2) for Precooked Dried Sea Cucumber does not list the critical control point of drying for controlling the food safety hazard of pathogenic bacteria growth and toxin formation (Staphylococcus aureus).\u003C\u002Fp>\n\n\u003Cp>You should respond in writing within fifteen (15) working days from your receipt of this letter. Your response should outline the specific things you are doing to correct these deviations. More specifically, your response should include documentation reflecting the changes you made, such as a copy of your revised HACCP plan or plans, five (5) consecutive days of completed monitoring records (i.e., complete sets of monitoring records for the production of 5 production date codes of products) to demonstrate implementation of the plan, and any additional information that you wish to supply that provides assurance of your intent to fully comply now and in the future with the seafood HACCP regulation. If you cannot complete all corrections within 15 days, you should explain the reason for your delay and state when you will correct any remaining violations. If you believe that your product is not in violation of the Act, include your reasoning and any supporting information for our consideration.\u003C\u002Fp>\n\n\u003Cp>If you do not respond or if we find your response inadequate, we may take further action. For instance, we may take further action to refuse admission of your imported fish or fishery products under section 801(a) of the Act (21 U.S.C. § 381(a)), including placing them on detention without physical examination (DWPE). FDA’s DWPE is an administrative procedure whereby products offered for import into the United States may be detained without physical examination upon entry. DWPE information may be conveyed in FDA’s Import Alerts. For your information, an example of an Import Alert that conveys information specific to foreign firms that are not in compliance with the seafood HACCP regulation is Import Alert 16-120. This alert can be found on FDA’s web site at: \u003Ca href=\"http:\u002F\u002Fwww.accessdata.fda.gov\u002Fcms_ia\u002Fimportalert_25.html\">http:\u002F\u002Fwww.accessdata.fda.gov\u002Fcms_ia\u002Fimportalert_25.html\u003C\u002Fa>.\u003C\u002Fp>\n\n\u003Cp>This letter may not list all the deviations at your facility. You are responsible for ensuring that your processing plant operates in compliance with the Act and all applicable regulations, including the seafood HACCP regulation (21 CFR Part 123) and the current Good Manufacturing Practice Hazard Analysis, and Risk-Based Preventive Controls for Human Food regulation (CGMP &amp; PC rule), Title 21, Code of Federal Regulations, Part 117 (21 CFR Part 117 Subpart B). You also have a responsibility to use procedures to prevent further violations of the Act and all applicable regulations.\u003C\u002Fp>\n\n\u003Cp>Please send your reply to the Food and Drug Administration, Attention: Alyssa Piontkowski, Compliance Officer, Office of Compliance, Division of Enforcement, Food Adulteration and Assessment Branch (HFS-607), 5001 Campus Drive, College Park, MD 20740 U.S.A. If you have any questions regarding any issues in this letter, please contact Alyssa Piontkowski via email at: Alyssa.Clendenin@fda.hhs.gov. Please include reference #635746 on any submissions and within the subject line of any email correspondence to the agency.\u003C\u002Fp>\n\n\u003Cp>Sincerely,\u003Cbr>\n\u002FS\u002F\u003C\u002Fp>\n\n\u003Cp>Ann M. Oxenham\u003Cbr>\nDirector\u003Cbr>\nOffice of Compliance\u003Cbr>\nCenter for Food Safety and Applied Nutrition\u003C\u002Fp>\n\n\n\u003C!--BEGIN QUALTRICS WEBSITE FEEDBACK SNIPPET-->\n\u003C!--BEGIN QUALTRICS WEBSITE FEEDBACK SNIPPET-->\n\n\n\n              \n                                            \n              \n            ","Delivery Method:\n\nVia Express Delivery\n\nProduct:\n\nFood & Beverages\n\nRecipient:\n\nRecipient Name\n\nMr. Vladimir Suarez Ocampo\n\nRecipient Title\n\nCo-Owner and General Manager\n\nVlazar Costa Caribe S.A.\n\nBarrio Spanish Town Contiguo\n\nIglesia Morava Santa Trinidad\n\nPuerto Cabezas,\n\nNicaragua\n\nIssuing Office:\n\nCenter for Food Safety and Applied Nutrition (CFSAN)\n\nUnited States\n\nAugust 15, 2022\n\nWARNING LETTER\n\nReference #635746\n\nDear Mr. Vladimir Suarez Ocampo:\n\nThe United States Food and Drug Administration (FDA) conducted a Foreign Remote Regulatory Assessment (FRRA) of your seafood processing facility, Vlazar Costa Caribe S.A., located at Barrio Spanish Town Contiguo Iglesia Morava Santa Trinidad Puerto Cabezas, Nicaragua on April 26 – 29, 2022. During the remote assessment, we found that you had serious violations of the seafood Hazard Analysis and Critical Control Point (HACCP) regulation, Title 21, Code of Federal Regulations (21CFR Part 123). At the conclusion of the assessment, the FDA investigator discussed items of concern. To date, your firm has not responded to the discussion items identified during the FFRA.\n\nIn accordance with 21 CFR 123.6(g), failure of a processor of fish or fishery products to have and implement a HACCP plan that complies with this section or otherwise operate in accordance with the requirements of Part 123, renders the fish or fishery products adulterated within the meaning of section 402(a)(4) of the Federal Food, Drug, and Cosmetic Act (the Act), 21 U.S.C. § 342(a)(4). Accordingly, your dried sea cucumber products are adulterated, in that they have been prepared, packed, or held under conditions whereby they may have been rendered injurious to health. You may find the Act, the seafood HACCP regulation, and the 4th Edition of the Fish and Fisheries Products Hazards & Controls Guidance (the Hazards Guide) through links in FDA's home page at www.fda.gov.\n\nYour significant deviations are as follows:\n\nYou must conduct a hazard analysis to determine whether there are food safety hazards that are reasonably likely to occur and have a HACCP plan that, at a minimum, lists the critical control points, to comply with 21 CFR 123.6(a) and (c)(2). A critical control point is defined in 21 CFR 123.3(b) as a “point, step, or procedure in a food process at which control can be applied and a food safety hazard can as a result be prevented, eliminated, or reduced to acceptable levels.” However, your firm’s HACCP plan (Version 2) for Precooked Dried Sea Cucumber does not list the critical control point of drying for controlling the food safety hazard of pathogenic bacteria growth and toxin formation (Staphylococcus aureus).\n\nYou should respond in writing within fifteen (15) working days from your receipt of this letter. Your response should outline the specific things you are doing to correct these deviations. More specifically, your response should include documentation reflecting the changes you made, such as a copy of your revised HACCP plan or plans, five (5) consecutive days of completed monitoring records (i.e., complete sets of monitoring records for the production of 5 production date codes of products) to demonstrate implementation of the plan, and any additional information that you wish to supply that provides assurance of your intent to fully comply now and in the future with the seafood HACCP regulation. If you cannot complete all corrections within 15 days, you should explain the reason for your delay and state when you will correct any remaining violations. If you believe that your product is not in violation of the Act, include your reasoning and any supporting information for our consideration.\n\nIf you do not respond or if we find your response inadequate, we may take further action. For instance, we may take further action to refuse admission of your imported fish or fishery products under section 801(a) of the Act (21 U.S.C. § 381(a)), including placing them on detention without physical examination (DWPE). FDA’s DWPE is an administrative procedure whereby products offered for import into the United States may be detained without physical examination upon entry. DWPE information may be conveyed in FDA’s Import Alerts. For your information, an example of an Import Alert that conveys information specific to foreign firms that are not in compliance with the seafood HACCP regulation is Import Alert 16-120. This alert can be found on FDA’s web site at: http:\u002F\u002Fwww.accessdata.fda.gov\u002Fcms_ia\u002Fimportalert_25.html.\n\nThis letter may not list all the deviations at your facility. You are responsible for ensuring that your processing plant operates in compliance with the Act and all applicable regulations, including the seafood HACCP regulation (21 CFR Part 123) and the current Good Manufacturing Practice Hazard Analysis, and Risk-Based Preventive Controls for Human Food regulation (CGMP & PC rule), Title 21, Code of Federal Regulations, Part 117 (21 CFR Part 117 Subpart B). You also have a responsibility to use procedures to prevent further violations of the Act and all applicable regulations.\n\nPlease send your reply to the Food and Drug Administration, Attention: Alyssa Piontkowski, Compliance Officer, Office of Compliance, Division of Enforcement, Food Adulteration and Assessment Branch (HFS-607), 5001 Campus Drive, College Park, MD 20740 U.S.A. If you have any questions regarding any issues in this letter, please contact Alyssa Piontkowski via email at: Alyssa.Clendenin@fda.hhs.gov. Please include reference #635746 on any submissions and within the subject line of any email correspondence to the agency.\n\nSincerely,\n\n\u002FS\u002F\n\nAnn M. Oxenham\n\nDirector\n\nOffice of Compliance\n\nCenter for Food Safety and Applied Nutrition","2026-08-20T01:35:26.827+00:00",[23,24,25,9,10,26,26,26],"\u003Ctime datetime=\"2022-09-13T13:20:00Z\">09\u002F13\u002F2022\u003C\u002Ftime>\n","\u003Ctime datetime=\"2022-08-15T04:00:00Z\">08\u002F15\u002F2022\u003C\u002Ftime>\n","\u003Ca href=\"\u002Finspections-compliance-enforcement-and-criminal-investigations\u002Fwarning-letters\u002Fvlazar-costa-caribe-sa-635746-08152022\">Vlazar Costa Caribe S.A.\u003C\u002Fa>","","2026-08-18T06:42:29.145918+00:00","2026-08-20T02:24:56.344395+00:00",{"510k":30,"classification":31,"enforcement":32,"event":33,"pma":34,"warning_letter":35},"2026-08-18T06:35:18.347+00:00","2026-08-18T05:52:53.75+00:00","2026-08-18T08:01:54.918+00:00","2026-08-19T02:58:35.995+00:00","2026-08-18T06:36:30.549+00:00","2026-08-20T03:28:02.95+00:00"]