[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"category-devices-血液検査用器具":3},[4,33,48,63,77,95,111,127,142,157,172,187,203,214,229,239,253,265,276,288,302,315,328,338,352,364,376,388,401,415,428,438,450,462,474,485,503,513,525,537,549,558,567,575,581,590,597,603,610,616,622,628,636,644,651,661,668,677,685,692,699,706,713,720,727,735,741,748,755,761,768,777,784,791,799,805,815,822,829,837,845,853,861,867,874,881,887,895,904],{"id":5,"class_notification":6,"specific_maintenance_notification":7,"installation_management_notification":8,"category_code":9,"category_name":10,"subcategory_name":11,"code":12,"generic_name":13,"generic_name_definition":14,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":19,"old_generic_name":13,"old_class_classification":15,"old_repair_category":20,"revision_count":21,"last_updated_date":22,"data_exist":23,"product_exist":23,"market_size":24,"growth_ratio":25,"average_price":26,"domestic_ratio":27,"product_count":28,"company_count":29,"market_size_unit":30,"average_price_unit":31,"created_at":32},3488,"3-0251","1033","197","器17","血液検査用器具","臨床化学検査機器","35743010","ディスクリート方式臨床化学自動分析装置","元来の方法を大きく変えずに、用手法による臨床化学分析法を着実に自動化又は機械化した装置をいう。測定は、個別の試験チューブやキュベットで行われ、コンベア又はターンテーブルで運ばれる途中に各ステーションで試料、希釈液及び試薬が調合される。混合、インキュベーション及び発色のための時間が考慮されており、その後に、内蔵されているフィルタ光度計又は分光光度計で反応混合物の吸光度を測定する。移動式のものを除く。","Ⅰ","－","該当","G8","080202042","非特定",1,"平成29年10月26日",true,715.3,2.49,644.12,99.9,56,13,"億円/年","万円/個","2025-03-24T01:34:40.770687+00:00",{"id":34,"class_notification":35,"specific_maintenance_notification":36,"installation_management_notification":37,"category_code":9,"category_name":10,"subcategory_name":11,"code":38,"generic_name":39,"generic_name_definition":40,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":41,"old_generic_name":39,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":43,"growth_ratio":44,"average_price":45,"domestic_ratio":46,"product_count":47,"company_count":29,"market_size_unit":30,"average_price_unit":31,"created_at":32},3512,"3-0275","1178","236","36223010","免疫発光測定装置","標識として使用する化学発光物質から発せられる光の強度を測定することで、薬物、蛋白質又はホルモン等の体液中の物質を同定及び定量するために用いる自動又は半自動の装置をいう。移動式のものを除く。","080210083",null,549,-8.34,1036.97,95.6,34,{"id":49,"class_notification":50,"specific_maintenance_notification":51,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":53,"generic_name":54,"generic_name_definition":55,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":56,"old_generic_name":54,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":57,"growth_ratio":58,"average_price":59,"domestic_ratio":60,"product_count":61,"company_count":62,"market_size_unit":30,"average_price_unit":31,"created_at":32},3537,"3-0300","1084","血液検査機器","35476000","血球計数装置","血液中の有形成分（赤血球、白血球、血小板）を電気インピーダンス、光散乱又は染料結合により定量する自動又は半自動の装置をいう。本装置は規定量の血液中に存在する赤血球及び白血球の絶対数を測定する。血小板の絶対数の測定、赤血球指数の計算、及び完全又は三部の白血球分画細胞の計数を行う装置もある。","080402002",329.1,43.13,239.92,97.2,89,10,{"id":64,"class_notification":65,"specific_maintenance_notification":66,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":67,"generic_name":68,"generic_name_definition":69,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":70,"old_generic_name":68,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":71,"growth_ratio":72,"average_price":73,"domestic_ratio":74,"product_count":75,"company_count":76,"market_size_unit":30,"average_price_unit":31,"created_at":32},3543,"3-0306","1080","35514000","血液凝固分析装置","フィブリノーゲン、フィブリン、血小板等の止血（出血の抑制）成分の定性・定量や止血時間の計測を行う自動又は半自動の装置をいう。","080406000",93.67,22.98,328.58,95.1,70,15,{"id":78,"class_notification":79,"specific_maintenance_notification":80,"installation_management_notification":81,"category_code":9,"category_name":10,"subcategory_name":82,"code":83,"generic_name":84,"generic_name_definition":85,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":86,"old_generic_name":87,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":89,"growth_ratio":90,"average_price":91,"domestic_ratio":92,"product_count":93,"company_count":94,"market_size_unit":30,"average_price_unit":31,"created_at":32},3591,"3-0354","1063","204","その他の医用検体検査装置","70192000","遺伝子解析装置","生体試料から抽出した核酸分子の配列情報を解析する装置をいう。解析を確実にするため、通常、核酸分子の増幅を行う。","089999006","他に分類されない医用検体検査機器","☆",69.63,-10.5,189.55,5.8,78,36,{"id":96,"class_notification":97,"specific_maintenance_notification":98,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":99,"code":100,"generic_name":101,"generic_name_definition":102,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":103,"old_generic_name":104,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":105,"growth_ratio":106,"average_price":107,"domestic_ratio":108,"product_count":109,"company_count":110,"market_size_unit":30,"average_price_unit":31,"created_at":32},3568,"3-0331","1089","医用検体前処理装置","38757000","検体前処理装置","試料の前処理装置をいう。検体分析のために試料を前処理する制御コンピュータを備えた自動化システムで、試料ハンドラ、プロセッサ又はロボット等の種々の検査用装置から構成される。単なる試料容器の搬送、検体の希釈、分注を除く。","080899002","その他の医用検体前処理装置",54.93,-28.26,255.59,96.5,97,19,{"id":112,"class_notification":113,"specific_maintenance_notification":114,"installation_management_notification":115,"category_code":9,"category_name":10,"subcategory_name":11,"code":116,"generic_name":117,"generic_name_definition":118,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":119,"old_generic_name":120,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":121,"growth_ratio":122,"average_price":123,"domestic_ratio":124,"product_count":125,"company_count":126,"market_size_unit":30,"average_price_unit":31,"created_at":32},3510,"3-0273","1177","235","35707010","免疫蛍光分析装置","抗原/抗体の活性値を測定する為に蛍光マーカを用いる方法で、生体液中の成分を試薬と反応させ、蛍光試薬から発せられる蛍光強度を検出し、抗原/抗体量を自動又は半自動で測定する装置をいう。移動式のものを除く。","080210067","免疫蛍光測定装置",49.89,-2.27,1188.13,98.4,16,8,{"id":128,"class_notification":129,"specific_maintenance_notification":130,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":82,"code":131,"generic_name":132,"generic_name_definition":133,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":134,"old_generic_name":135,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":136,"growth_ratio":137,"average_price":138,"domestic_ratio":139,"product_count":140,"company_count":141,"market_size_unit":30,"average_price_unit":31,"created_at":32},3588,"3-0351","1114","70191000","自動染色装置","病理検査の組織標本や細胞診、血液検査等の標本を作製する装置をいう。染色を行う装置又は塗抹のみ行う装置を含む。","089904990","その他の病理検査装置",42.4,-38.83,221.31,82.8,64,21,{"id":143,"class_notification":144,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":145,"generic_name":146,"generic_name_definition":147,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":149,"old_generic_name":150,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":151,"growth_ratio":152,"average_price":153,"domestic_ratio":154,"product_count":155,"company_count":156,"market_size_unit":30,"average_price_unit":31,"created_at":32},3549,"3-0312","15110000","血液塗抹標本作製装置","ガラススライド上の血液標本のフィルム（血液塗抹標本）の作製に用いる自動装置をいう。本品は試験管からの試料採取、顕微鏡スライドの運搬、塗抹標本の長さ及び厚さの調節を行う。血液フィルムの染色を行うものもある。検査室での分析に適切な標本を作製するために使用し、ユーザが病原体を含む血液標本に接触しないようにする。","非該当","080414009","血液検査装置の付属品",36.29,-6.45,502.05,100,12,5,{"id":158,"class_notification":159,"specific_maintenance_notification":160,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":161,"generic_name":162,"generic_name_definition":163,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":166,"growth_ratio":167,"average_price":168,"domestic_ratio":169,"product_count":170,"company_count":171,"market_size_unit":30,"average_price_unit":31,"created_at":32},3523,"3-0286","1025","35968000","グリコヘモグロビン分析装置","HPLC、電気泳動又はイムノアッセイ等の方法を用いて、ヒト血液中に存在するグリコヘモグロビン（HbA1c）濃度を測定する専用装置をいう。","080212999","その他の専用臨床化学分析装置",28.25,-32.18,139.07,72.1,30,9,{"id":173,"class_notification":174,"specific_maintenance_notification":175,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":176,"generic_name":177,"generic_name_definition":178,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":179,"old_generic_name":180,"old_class_classification":15,"old_repair_category":20,"revision_count":21,"last_updated_date":181,"data_exist":23,"product_exist":23,"market_size":182,"growth_ratio":183,"average_price":184,"domestic_ratio":185,"product_count":186,"company_count":62,"market_size_unit":30,"average_price_unit":31,"created_at":32},3492,"3-0255","1075","34549000","乾式臨床化学分析装置","化学物質、ヒト組織試料、又は試薬とヒト組織との反応により生じた化学物質の定性・定量分析に用いる自動又は半自動の装置をいう。試料を含浸した試薬浸透テストストリップ又は多層フィルムから反射される光量や電気化学的な反応等を測定することにより機能する。","080202084","乾式臨床化学自動分析装置","令和4年4月13日",24.51,-25.3,27.14,77.9,38,{"id":188,"class_notification":189,"specific_maintenance_notification":190,"installation_management_notification":191,"category_code":9,"category_name":10,"subcategory_name":192,"code":193,"generic_name":194,"generic_name_definition":195,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":196,"old_generic_name":197,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":198,"growth_ratio":199,"average_price":200,"domestic_ratio":201,"product_count":202,"company_count":156,"market_size_unit":30,"average_price_unit":31,"created_at":32},3569,"3-0332","1081","210","血清検査装置","35635000","血液型分析装置","輸血前検査（ABO型及び亜型判定、Rh及び他の赤血球の表現型判定、抗体検出、梅毒検査、又は肝炎検査）に用いる自動又は半自動の装置をいう。","081002005","血液型判定装置",24.43,-16.29,1470.17,0,20,{"id":204,"class_notification":205,"specific_maintenance_notification":206,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":207,"generic_name":208,"generic_name_definition":209,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":41,"old_generic_name":39,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":210,"growth_ratio":211,"average_price":212,"domestic_ratio":154,"product_count":213,"company_count":213,"market_size_unit":30,"average_price_unit":31,"created_at":32},3513,"3-0276","1061","36223020","移動式免疫発光測定装置","標識として使用する化学発光物質から発せられる光の強度を測定することで、薬物、蛋白質又はホルモン等の体液中の物質を同定及び定量するために用いる自動又は半自動の装置をいう。移動式のものをいう。",22.58,-1.18,127.29,6,{"id":215,"class_notification":216,"specific_maintenance_notification":217,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":218,"generic_name":219,"generic_name_definition":220,"class_classification":221,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":16,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":21,"last_updated_date":222,"data_exist":23,"product_exist":23,"market_size":223,"growth_ratio":224,"average_price":225,"domestic_ratio":226,"product_count":227,"company_count":29,"market_size_unit":30,"average_price_unit":228,"created_at":32},352,"1-0352","169","30854000","自己検査用グルコース測定器","自己検査用に血中グルコース又は血中ケトンを測定する測定器をいう。患者が自宅で使用できるように製造されたものである。","Ⅲ","平成28年3月25日",16.64,-36.07,2739,79.2,44,"円/個",{"id":230,"class_notification":231,"specific_maintenance_notification":232,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":233,"generic_name":234,"generic_name_definition":235,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":19,"old_generic_name":13,"old_class_classification":15,"old_repair_category":20,"revision_count":21,"last_updated_date":22,"data_exist":23,"product_exist":23,"market_size":236,"growth_ratio":237,"average_price":238,"domestic_ratio":154,"product_count":155,"company_count":213,"market_size_unit":30,"average_price_unit":31,"created_at":32},3489,"3-0252","1014","35743020","移動式ディスクリート方式臨床化学自動分析装置","元来の方法を大きく変えずに、用手法による臨床化学分析法を着実に自動化又は機械化した装置をいう。測定は、個別の試験チューブやキュベットで行われ、コンベア又はターンテーブルで運ばれる途中に各ステーションで試料、希釈液及び試薬が調合される。混合、インキュベーション及び発色のための時間が考慮されており、その後に、内蔵されているフィルタ光度計又は分光光度計で反応混合物の吸光度を測定する。移動式のものをいう。",12.04,-9.62,257.54,{"id":240,"class_notification":241,"specific_maintenance_notification":242,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":243,"generic_name":244,"generic_name_definition":245,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":246,"old_generic_name":247,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":248,"growth_ratio":249,"average_price":250,"domestic_ratio":251,"product_count":202,"company_count":252,"market_size_unit":30,"average_price_unit":31,"created_at":32},3494,"3-0257","1156","36910000","汎用分光光度分析装置","ガス又は液体中の物質の光度（光学）的特性を測定することにより、物質濃度を定量する装置をいう。診断及び研究を使用用途とする。","080204004","医用分光光度計",12.02,-18.1,1129.14,50,11,{"id":254,"class_notification":255,"specific_maintenance_notification":256,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":257,"generic_name":258,"generic_name_definition":259,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":260,"old_generic_name":258,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":261,"growth_ratio":262,"average_price":263,"domestic_ratio":264,"product_count":110,"company_count":156,"market_size_unit":30,"average_price_unit":31,"created_at":32},3541,"3-0304","1082","35479000","血液像自動分析装置","赤血球、白血球又は血小板等の血球の分類、小赤血球又は大赤血球等の特徴、及び数を同定する自動又は半自動の装置をいう。","080404006",11.15,-38.46,3621.09,42.9,{"id":266,"class_notification":267,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":268,"generic_name":269,"generic_name_definition":270,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":70,"old_generic_name":68,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":271,"growth_ratio":272,"average_price":273,"domestic_ratio":274,"product_count":171,"company_count":275,"market_size_unit":30,"average_price_unit":31,"created_at":32},3542,"3-0305","35505000","凝固測定用経過時間タイマ","時間の長さを計測・表示するために用いる装置で、全血で凝固に要する時間を自動的に表示、記録するものをいう。",10.05,31.82,2.99,0.2,4,{"id":277,"class_notification":278,"specific_maintenance_notification":279,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":280,"generic_name":281,"generic_name_definition":282,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":119,"old_generic_name":120,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":283,"growth_ratio":284,"average_price":285,"domestic_ratio":286,"product_count":287,"company_count":76,"market_size_unit":30,"average_price_unit":31,"created_at":32},3511,"3-0274","1060","35707020","移動式免疫蛍光分析装置","抗原/抗体の活性値を測定する為に蛍光マーカを用いる方法で、生体液中の成分を試薬と反応させ、蛍光試薬から発せられる蛍光強度を検出し、抗原/抗体量を自動又は半自動で測定する装置をいう。移動式のものをいう。",9.07,40.41,124.48,63.3,24,{"id":289,"class_notification":290,"specific_maintenance_notification":291,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":292,"generic_name":293,"generic_name_definition":294,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":295,"old_generic_name":293,"old_class_classification":296,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":297,"growth_ratio":298,"average_price":299,"domestic_ratio":300,"product_count":301,"company_count":29,"market_size_unit":30,"average_price_unit":31,"created_at":32},3516,"3-0279","1026","36730000","グルコース分析装置","血液中の糖（ブドウ糖）濃度を測定する検査室用装置をいう。","080212029","Ⅱ",7.94,4.04,17.07,68.8,45,{"id":303,"class_notification":304,"specific_maintenance_notification":305,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":306,"generic_name":307,"generic_name_definition":308,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":309,"old_generic_name":310,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":311,"growth_ratio":312,"average_price":313,"domestic_ratio":314,"product_count":125,"company_count":62,"market_size_unit":30,"average_price_unit":31,"created_at":32},3493,"3-0256","1037","34550000","パック式臨床化学分析装置","化学物質又はヒト組織試料の定性・定量分析に用いる自動又は半自動の装置をいい、袋などの容器に用意された試薬と結合した試料を光度分析することにより機能する。本装置はグラフィック及びデータ出力の機能も備えている。","080202101","パック式臨床化学自動分析装置",6.69,-40.74,26.66,98.3,{"id":316,"class_notification":317,"specific_maintenance_notification":318,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":319,"generic_name":320,"generic_name_definition":321,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":322,"old_generic_name":323,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":324,"growth_ratio":325,"average_price":326,"domestic_ratio":201,"product_count":252,"company_count":327,"market_size_unit":30,"average_price_unit":31,"created_at":32},3507,"3-0270","1048","37036000","マイクロタイタプレートリーダ","マイクロタイタプレート上の試験結果を判読するために用いる装置をいう。結果はプリンター又はスクリーンに表示することができる。試験試料は血液､試薬又は混合物等である。この過程は固相酵素免疫測定（ELISA）試験としても知られる。","080210025","免疫吸光測定装置",6.65,-46.67,5906.48,7,{"id":329,"class_notification":330,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":331,"generic_name":332,"generic_name_definition":333,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":149,"old_generic_name":150,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":334,"growth_ratio":335,"average_price":336,"domestic_ratio":337,"product_count":171,"company_count":156,"market_size_unit":30,"average_price_unit":228,"created_at":32},3550,"3-0313","70185000","血液凝固測定装置専用カートリッジ","血液凝固時間を測定する分析装置の専用カートリッジをいう。",6.34,55.94,1939,0.3,{"id":339,"class_notification":340,"specific_maintenance_notification":341,"installation_management_notification":342,"category_code":9,"category_name":10,"subcategory_name":11,"code":343,"generic_name":344,"generic_name_definition":345,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":346,"old_generic_name":347,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":348,"growth_ratio":349,"average_price":350,"domestic_ratio":351,"product_count":29,"company_count":213,"market_size_unit":30,"average_price_unit":31,"created_at":32},3505,"3-0268","1094","214","35706010","酵素免疫測定装置","抗原/抗体複合体の存在下で酵素反応により、生体液中の物質の同定又は濃度を測定する自動又は半自動の装置をいう。移動式のものを除く。","080210009","免疫反応測定装置",5.99,69.68,325.55,99.5,{"id":353,"class_notification":354,"specific_maintenance_notification":355,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":356,"generic_name":357,"generic_name_definition":358,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":359,"old_generic_name":360,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":361,"growth_ratio":201,"average_price":362,"domestic_ratio":363,"product_count":76,"company_count":275,"market_size_unit":30,"average_price_unit":31,"created_at":32},3502,"3-0265","1131","31365000","蛋白分画電気泳動分析装置","血液、尿、脳脊髄及び他の体液中の蛋白分画を測定する自動又は半自動の装置をいう。蛋白分画は体液中の異常蛋白、及び組織破壊を伴う疾病で産生される蛋白の遺伝的変種の検出補助に使用される。","080208028","蛋白分画電気泳動装置",4.43,2468.4,53.3,{"id":365,"class_notification":366,"specific_maintenance_notification":367,"installation_management_notification":368,"category_code":9,"category_name":10,"subcategory_name":82,"code":369,"generic_name":370,"generic_name_definition":371,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":86,"old_generic_name":87,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":372,"growth_ratio":373,"average_price":374,"domestic_ratio":375,"product_count":110,"company_count":213,"market_size_unit":30,"average_price_unit":31,"created_at":32},3592,"3-0355","1041","199","70193000","フローサイトメータ","フローセル中で細胞を移動させ、レーザ光等を照射し、散乱光や蛍光の強度、種類から細胞を同定あるいは定量したり、細胞の存在比率を解析したりする装置をいう。細胞を蛍光色素で標識することもある。",4.21,28.57,774.43,80,{"id":377,"class_notification":378,"specific_maintenance_notification":379,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":380,"generic_name":381,"generic_name_definition":382,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":383,"old_generic_name":384,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":385,"growth_ratio":386,"average_price":387,"domestic_ratio":201,"product_count":62,"company_count":156,"market_size_unit":30,"average_price_unit":31,"created_at":32},3552,"3-0315","1047","35481000","ヘモグロビン分析装置","分光光度法により血液中のヘモグロビンを測定する装置をいう。","080499008","その他の血液検査機器",3.79,-4.77,3.14,{"id":389,"class_notification":390,"specific_maintenance_notification":391,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":392,"generic_name":393,"generic_name_definition":394,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":395,"old_generic_name":396,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":398,"growth_ratio":201,"average_price":399,"domestic_ratio":154,"product_count":400,"company_count":400,"market_size_unit":30,"average_price_unit":31,"created_at":32},3515,"3-0278","1174","70182000","便潜血測定装置","イムノクロマト法等によるアッセイ結果を、その着色の反射光等を用いて便中ヘモグロビン類を検出する自動又は半自動の装置をいう。","080210995","その他の免疫反応測定装置",false,3.09,300.3,3,{"id":402,"class_notification":403,"specific_maintenance_notification":404,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":405,"generic_name":406,"generic_name_definition":407,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":408,"old_generic_name":409,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":410,"data_exist":23,"product_exist":23,"market_size":411,"growth_ratio":412,"average_price":413,"domestic_ratio":154,"product_count":414,"company_count":126,"market_size_unit":30,"average_price_unit":31,"created_at":32},3498,"3-0261","1013","35902000","イオン選択性分析装置","外部参照電極及び内部参照電極を含むイオン選択性電極（ISE）を用いて、電位差等による種々の測定を行う自動又は半自動の装置をいう。汎用分析装置の一部又は独立型のものがある。各種のISE により特定の分析のための測定ができる。","080206040","電極式電解質分析装置","令和7年2月26日",2.83,4.39,23.03,23,{"id":416,"class_notification":417,"specific_maintenance_notification":418,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":419,"generic_name":420,"generic_name_definition":421,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":422,"old_generic_name":423,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":424,"growth_ratio":425,"average_price":426,"domestic_ratio":427,"product_count":125,"company_count":155,"market_size_unit":30,"average_price_unit":31,"created_at":32},3503,"3-0266","1034","15129000","デンシトメトリー分析装置","血清試料の分析のために電気泳動、薄層クロマトグラフィー又はイムノアッセイブロット試料分離により生じた支持体中のパターンからの透過光又は反射光を測定する自動又は半自動の装置をいう。種々の血清成分の分離分画の定量、及び非常に低い分画濃度の検出が可能である。光は電気エネルギーに変換され、一連の数理的計算により試料の正確な吸光度を示すシグナルが得られる。基本的には、光源、モノクロメータ、試料セル、検出器等が含まれる。","080208044","デンシトメータ",2.79,-35.52,8.51,95.5,{"id":429,"class_notification":430,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":82,"code":431,"generic_name":432,"generic_name_definition":433,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":86,"old_generic_name":87,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":434,"growth_ratio":435,"average_price":436,"domestic_ratio":437,"product_count":125,"company_count":327,"market_size_unit":30,"average_price_unit":31,"created_at":32},3590,"3-0353","36744000","精子・精液分析装置","試料中の精子の濃度を測定し活動度（運動性）の特性を示す装置をいう。",1.79,-8.14,64.81,26,{"id":439,"class_notification":440,"specific_maintenance_notification":441,"installation_management_notification":442,"category_code":9,"category_name":10,"subcategory_name":11,"code":443,"generic_name":444,"generic_name_definition":445,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":446,"old_generic_name":447,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":448,"growth_ratio":201,"average_price":449,"domestic_ratio":154,"product_count":126,"company_count":275,"market_size_unit":30,"average_price_unit":31,"created_at":32},3508,"3-0271","1179","237","35926010","免疫比濁分析装置","分析物と抗体とで反応生成された免疫複合体からの光散乱強度測定により、体液中の分析物を定量する自動又は半自動の光散乱分析装置をいう。専用の試薬を用いる。本装置はレーザネフェロメータとも呼ばれる。移動式のものを除く。","080210041","免疫比濁測定装置",1.46,1328,{"id":451,"class_notification":452,"specific_maintenance_notification":453,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":454,"generic_name":455,"generic_name_definition":456,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":457,"old_generic_name":455,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":458,"growth_ratio":459,"average_price":460,"domestic_ratio":461,"product_count":29,"company_count":327,"market_size_unit":30,"average_price_unit":31,"created_at":32},3519,"3-0282","1122","36458000","浸透圧分析装置","溶液のオスモル濃度（単位体積当りの溶質の量）を測定する装置をいう。","080212087",1.32,-60.53,89.91,49.4,{"id":463,"class_notification":464,"specific_maintenance_notification":465,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":466,"generic_name":467,"generic_name_definition":468,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":346,"old_generic_name":347,"old_class_classification":15,"old_repair_category":20,"revision_count":21,"last_updated_date":469,"data_exist":23,"product_exist":23,"market_size":470,"growth_ratio":471,"average_price":472,"domestic_ratio":473,"product_count":29,"company_count":126,"market_size_unit":30,"average_price_unit":31,"created_at":32},3504,"3-0267","1130","30857000","蛋白質分析装置","免疫反応によって生じる特異的蛋白質の同定又は濃度測定に用いる自動化又は半自動化された専用装置をいう。ラテックス免疫反応を用いるものを含む。","平成29年9月29日",1.29,-35.57,36.84,32.2,{"id":475,"class_notification":476,"specific_maintenance_notification":477,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":478,"generic_name":479,"generic_name_definition":480,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":481,"old_generic_name":479,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":482,"growth_ratio":483,"average_price":484,"domestic_ratio":251,"product_count":29,"company_count":213,"market_size_unit":30,"average_price_unit":31,"created_at":32},3546,"3-0309","1086","35473000","血小板凝集測定装置","血液凝固中の血小板の形状変化及び血小板凝集を測定する装置をいう。","080410001",1.06,-14.77,241.38,{"id":486,"class_notification":487,"specific_maintenance_notification":488,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":489,"code":490,"generic_name":491,"generic_name_definition":492,"class_classification":296,"ghtf_rule":493,"specific_maintenance":17,"installation_management":42,"repair_category":494,"qms_notification":16,"old_generic_name_code":495,"old_generic_name":496,"old_class_classification":296,"old_repair_category":497,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":498,"growth_ratio":499,"average_price":500,"domestic_ratio":501,"product_count":502,"company_count":110,"market_size_unit":30,"average_price_unit":31,"created_at":32},1570,"2-0367","544","生体検査用機器","70080000","機能検査オキシメータ","生体に照射した近赤外光を検出し、血液中のヘモグロビン濃度の変化を計測する装置をいう。","10-①","G2","060802084","オキシメータ","特定",0.86,107.14,69.78,88.2,32,{"id":504,"class_notification":505,"specific_maintenance_notification":506,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":507,"generic_name":508,"generic_name_definition":509,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":510,"growth_ratio":511,"average_price":512,"domestic_ratio":154,"product_count":62,"company_count":213,"market_size_unit":30,"average_price_unit":31,"created_at":32},3522,"3-0285","1039","35475000","ビリルビン分析装置","血液又は他の試料中のビリルビン濃度を、3つの方法（分光光度法、血液蛍光光度法、皮膚反射度）のうち1つを用いて直接又は間接的に測定する装置をいう。",0.77,-11.17,25,{"id":514,"class_notification":515,"specific_maintenance_notification":516,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":517,"generic_name":518,"generic_name_definition":519,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":520,"old_generic_name":518,"old_class_classification":15,"old_repair_category":20,"revision_count":21,"last_updated_date":521,"data_exist":23,"product_exist":23,"market_size":522,"growth_ratio":523,"average_price":524,"domestic_ratio":154,"product_count":414,"company_count":126,"market_size_unit":30,"average_price_unit":228,"created_at":32},3545,"3-0308","1126","35488000","赤血球沈降速度測定装置","全血試料中の赤血球の沈降（沈むこと）速度を測定する自動又は半自動の装置をいう。赤血球沈降速度（ESR）とも呼ばれる。","080408004","令和1年5月23日",0.72,-20.84,168,{"id":526,"class_notification":527,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":528,"generic_name":529,"generic_name_definition":530,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":531,"old_generic_name":532,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":533,"growth_ratio":534,"average_price":535,"domestic_ratio":536,"product_count":125,"company_count":275,"market_size_unit":30,"average_price_unit":228,"created_at":32},3539,"3-0302","35103000","手動式血球計数装置","手動式の血球計算板として機能する装置をいう。本装置は一定の深さのくぼみのあるガラスブロックと線で四角く区切られた平面から構成される。区切られた四角とカバーグラスの間の既知の容量中の血球を顕微鏡を通して計数する。","080402998","その他の血球計数装置",0.71,64.48,1336,2.8,{"id":538,"class_notification":539,"specific_maintenance_notification":540,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":541,"generic_name":542,"generic_name_definition":543,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":544,"old_generic_name":545,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":546,"growth_ratio":547,"average_price":548,"domestic_ratio":154,"product_count":327,"company_count":213,"market_size_unit":30,"average_price_unit":31,"created_at":32},3518,"3-0281","1097","36420000","高速液体クロマトグラフィ分析装置","アミノ酸又はホルモン等の液体試料成分を、高速液体クロマトグラフィー(HPLC)を用いて分離、同定及び定量する自動又は半自動の装置をいう。試料中の様々な重量の溶質は、圧力によりカラム中に分布する。本装置はグラフィック及びデータ出力の機能も備えている。","080212061","専用液体クロマトグラフ",0.18,275.86,16.15,{"id":550,"class_notification":551,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":552,"generic_name":553,"generic_name_definition":554,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":383,"old_generic_name":384,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":23,"product_exist":23,"market_size":555,"growth_ratio":556,"average_price":557,"domestic_ratio":154,"product_count":400,"company_count":400,"market_size_unit":30,"average_price_unit":228,"created_at":32},3553,"3-0316","36823000","粘度分析装置","流れに対する分子間力による流体の抵抗を測定するために用いる装置をいう。全血、血清又は血漿の分析にも使用される。",0.04,-15.23,2273,{"id":559,"class_notification":560,"specific_maintenance_notification":561,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":562,"generic_name":563,"generic_name_definition":564,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":21,"last_updated_date":565,"data_exist":23,"product_exist":23,"market_size":201,"growth_ratio":566,"average_price":201,"domestic_ratio":201,"product_count":252,"company_count":156,"market_size_unit":30,"average_price_unit":228,"created_at":32},4433,"3-1196","1211","57848001","質量分析装置","ヒト試料中の無機又は有機化合物をイオン化し、電場又は磁場による質量分離により同定及び定量する自動又は半自動の装置をいう。本装置は、化合物をイオン化する機構を有するイオン化部分、質量電荷比により化合物を分離する質量分離部分と到達したイオンを検出する検出器から構成される。本装置はグラフィック及びデータ出力の機能を備えており、分離装置（例えば、液体クロマトグラフィ装置、ガスクロマトグラフィ装置等）を含むものや、特定の物質の血中濃度測定に用いられるものも含む（ただし、測定対象となる物質に対する標準品が既に存在し、かつ、当該体外診断用医薬品が承認を必要としないものに限る）。診断機能を備えるものを除く。","令和6年9月17日",-100,{"id":568,"class_notification":569,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":99,"code":570,"generic_name":571,"generic_name_definition":572,"class_classification":15,"ghtf_rule":573,"specific_maintenance":16,"installation_management":42,"repair_category":16,"qms_notification":148,"old_generic_name_code":103,"old_generic_name":104,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":400,"company_count":574,"market_size_unit":42,"average_price_unit":42,"created_at":32},3565,"3-0328","16901000","細胞・血漿用血液分離装置","通常血液バンクに保存する目的で血球及び血漿等、血液のさまざまな成分を分離するために用いる検査装置をいう。本品は遠心力、圧力、膜等さまざまなプロセスを利用する。","1",2,{"id":576,"class_notification":577,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":99,"code":578,"generic_name":579,"generic_name_definition":580,"class_classification":15,"ghtf_rule":573,"specific_maintenance":16,"installation_management":42,"repair_category":16,"qms_notification":148,"old_generic_name_code":103,"old_generic_name":104,"old_class_classification":16,"old_repair_category":88,"revision_count":21,"last_updated_date":469,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3564,"3-0327","15113000","血球分離装置","幹細胞の選別等の過程の前に標的血球を分離するために用いる検査室用装置をいう。選択した抗体でコーティングした常磁性微小球等を用いる方法がある。この常磁性微小球は選択した細胞とロゼットを形成し、その細胞を分離する。磁気分離と組み合わせたさまざまな前処理により、この場合には標的細胞が放出される。",{"id":582,"class_notification":583,"specific_maintenance_notification":584,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":585,"generic_name":586,"generic_name_definition":587,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":588,"old_generic_name":589,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":400,"company_count":574,"market_size_unit":42,"average_price_unit":42,"created_at":32},3536,"3-0299","1172","70183000","微生物由来成分分析装置","血漿、血清中のエンドトキシン等の微生物由来成分を光学的に測定する装置をいう。","080299006","その他の臨床化学検査機器",{"id":591,"class_notification":592,"specific_maintenance_notification":593,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":594,"generic_name":595,"generic_name_definition":596,"class_classification":221,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":16,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},1089,"1-1091","1191","56687003","自己検査用血液凝固分析器","フィブリノーゲン、フィブリン、血小板等の止血(出血の抑制)成分の定性・定量や止血時間の自己検査を行う自動又は半自動の専用装置をいう。",{"id":598,"class_notification":599,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":600,"generic_name":601,"generic_name_definition":602,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":148,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":29,"company_count":400,"market_size_unit":42,"average_price_unit":42,"created_at":32},4440,"3-1203","55974001","赤血球沈降速度測定器具","全血試料中の赤血球の沈降（沈むこと）速度を手動で測定する器具をいう。赤血球沈降速度（ESR）とも呼ばれる。",{"id":604,"class_notification":605,"specific_maintenance_notification":606,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":607,"generic_name":608,"generic_name_definition":609,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3526,"3-0289","1132","36741000","窒素分析装置","生体液中の窒素（N2）量を分析する専用装置をいう。",{"id":611,"class_notification":612,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":82,"code":613,"generic_name":614,"generic_name_definition":615,"class_classification":221,"ghtf_rule":16,"specific_maintenance":16,"installation_management":42,"repair_category":16,"qms_notification":16,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},1147,"1-1149","60943013","遺伝子変異解析セット（がんゲノムプロファイリング検査用）","生体由来の試料から得られた遺伝子変異情報を基に、がんゲノムプロファイリング検査を行うために使用される遺伝子変異解析セットをいう。解析プログラム及びテンプレートDNA調製試薬より構成される。",{"id":617,"class_notification":618,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":82,"code":619,"generic_name":620,"generic_name_definition":621,"class_classification":221,"ghtf_rule":16,"specific_maintenance":16,"installation_management":42,"repair_category":16,"qms_notification":16,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},1200,"1-1202","71115003","生殖細胞系列遺伝子変異解析セット（疾患原因遺伝子検査用）","生体由来の試料から得られた生殖細胞系列由来の遺伝子変異情報を基に、疾患原因遺伝子の情報を取得するために使用される遺伝子変異解析セットをいう。解析プログラム及びテンプレートDNA調製試薬より構成される。",{"id":623,"class_notification":624,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":82,"code":625,"generic_name":626,"generic_name_definition":627,"class_classification":221,"ghtf_rule":16,"specific_maintenance":16,"installation_management":42,"repair_category":16,"qms_notification":16,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":574,"market_size_unit":42,"average_price_unit":42,"created_at":32},1165,"1-1167","71059023","体細胞遺伝子変異解析セット（抗悪性腫瘍薬適応判定用）","生体由来の試料から得られた体細胞由来の遺伝子変異情報を基に、抗悪性腫瘍薬の適応判定のために使用される遺伝子変異解析セットをいう。解析プログラム及びテンプレートDNA調製試薬より構成される。",{"id":629,"class_notification":630,"specific_maintenance_notification":631,"installation_management_notification":632,"category_code":9,"category_name":10,"subcategory_name":82,"code":633,"generic_name":634,"generic_name_definition":635,"class_classification":221,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":16,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},1157,"1-1159","1217","246","60943033","遺伝子変異解析システム（がんゲノムプロファイリング検査用）","生体由来の試料から得られた遺伝子変異情報を基に、がんゲノムプロファイリング検査を行うために使用される遺伝子変異解析システムをいう。DNAシークエンサー、シークエンシングサンプル調製試薬及び解析プログラムより構成され、テンプレート調製試薬等を構成品として含む場合もある。",{"id":637,"class_notification":638,"specific_maintenance_notification":639,"installation_management_notification":640,"category_code":9,"category_name":10,"subcategory_name":82,"code":641,"generic_name":642,"generic_name_definition":643,"class_classification":221,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":16,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},1166,"1-1168","1226","248","71081003","マラリア診断装置","核染色試薬を組み合わせることにより、原虫を含有する赤血球と正常な赤血球を計数し、マラリアに代表される原虫感染症の感染の有無を判定する装置をいう。",{"id":645,"class_notification":646,"specific_maintenance_notification":647,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":489,"code":648,"generic_name":649,"generic_name_definition":650,"class_classification":296,"ghtf_rule":493,"specific_maintenance":17,"installation_management":42,"repair_category":494,"qms_notification":16,"old_generic_name_code":495,"old_generic_name":496,"old_class_classification":296,"old_repair_category":497,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},1569,"2-0366","346","33275000","オキシヘモグロビン分析装置","血液中の酸素と結合しているヘモグロビンの濃度を測定する自動又は半自動の装置をいう。",{"id":652,"class_notification":653,"specific_maintenance_notification":654,"installation_management_notification":655,"category_code":9,"category_name":10,"subcategory_name":11,"code":656,"generic_name":657,"generic_name_definition":658,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":659,"old_generic_name":660,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3490,"3-0253","1066","205","35744010","遠心方式臨床化学分析装置","液体の移動及び混合を遠心力によって行う自動又は半自動の装置をいう。遠心機内で生じた反応を光度計でモニタする。試料と試薬の調合には個別のモジュールを必要とする。移動式のものを除く。","080202068","遠心方式臨床化学自動分析装置",{"id":662,"class_notification":663,"specific_maintenance_notification":664,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":665,"generic_name":666,"generic_name_definition":667,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":659,"old_generic_name":660,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3491,"3-0254","1058","35744020","移動式遠心方式臨床化学分析装置","液体の移動及び混合を遠心力によって行う自動又は半自動の装置をいう。遠心機内で生じた反応を光度計でモニターする。試料と試薬の調合には個別のモジュールを必要とする。移動式のものをいう。",{"id":669,"class_notification":670,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":671,"generic_name":672,"generic_name_definition":673,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":674,"old_generic_name":675,"old_class_classification":15,"old_repair_category":20,"revision_count":21,"last_updated_date":676,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3495,"3-0258","15128000","汗試験用イオン導入装置","発汗を誘発して汗を採取し、塩化物又は塩化物とナトリウムの有無を分析する装置をいう。この分析結果は嚢胞性線維症の指標となる。","080206008","電解質分析装置","平成27年9月18日",{"id":678,"class_notification":679,"specific_maintenance_notification":680,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":681,"generic_name":682,"generic_name_definition":683,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":684,"old_generic_name":682,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3496,"3-0259","1065","35826000","炎光式電解質分析装置","幾つかの金属元素は熱エネルギーを吸収して電子を励起し、よりエネルギーの高い状態になるという事実に基づいて、ナトリウム、カリウム、リチウム又はカルシウム等の電解質を測定する自動又は半自動の装置をいう。汎用分析装置に組み込まれたものと独立型のものがある。本装置は試料を火炎中に吸引するバーナ、特定の波長を取り出すモノクロメータ、光検出器及び指示計から構成される。","080206024",{"id":686,"class_notification":687,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":82,"code":688,"generic_name":689,"generic_name_definition":690,"class_classification":296,"ghtf_rule":691,"specific_maintenance":16,"installation_management":42,"repair_category":16,"qms_notification":16,"old_generic_name_code":86,"old_generic_name":87,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},1813,"2-0610","34122000","骨盤検査キット","骨盤検査を実施するために必要な各種器具、標本収集材料、及び医薬品を全て含むプレパッケージされたトレー、キット又はセットをいう。","6",{"id":693,"class_notification":694,"specific_maintenance_notification":695,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":696,"generic_name":697,"generic_name_definition":698,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":346,"old_generic_name":347,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":574,"company_count":574,"market_size_unit":42,"average_price_unit":42,"created_at":32},3506,"3-0269","1059","35706020","移動式酵素免疫測定装置","抗原/抗体複合体の存在下で酵素反応により、生体液中の物質の同定又は濃度を測定する自動又は半自動の装置をいう。移動式のものをいう。",{"id":700,"class_notification":701,"specific_maintenance_notification":702,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":703,"generic_name":704,"generic_name_definition":705,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":446,"old_generic_name":447,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":400,"company_count":574,"market_size_unit":42,"average_price_unit":42,"created_at":32},3509,"3-0272","1062","35926020","移動式免疫比濁分析装置","分析物と抗体とで反応生成された免疫複合体からの光散乱強度測定により、体液中の分析物を定量する自動又は半自動の光散乱分析装置をいう。専用の試薬を用いる。本装置はレーザネフェロメータとも呼ばれる。移動式のものをいう。",{"id":707,"class_notification":708,"specific_maintenance_notification":709,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":710,"generic_name":711,"generic_name_definition":712,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3521,"3-0284","1029","30855000","コレステロール分析装置","血清・全血中のコレステロールを測定する装置をいう。",{"id":714,"class_notification":715,"specific_maintenance_notification":716,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":717,"generic_name":718,"generic_name_definition":719,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":588,"old_generic_name":589,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3532,"3-0295","1050","17477000","メタンガス分析装置","呼気標本中のメタン含有量を測定するための分析装置をいう。通常、百万分率（ppm）で表される。本品は通常、電気化学クロマトグラフィ又はガスクロマトグラフィ測定法を利用する。このような分析装置の大半は、呼気標本中の水素又は二酸化炭素含有量も測定することができ、細菌による炭水化物分解不全及び腸内細菌異常増殖による小腸の機能障害を測定するために用いる。",{"id":721,"class_notification":722,"specific_maintenance_notification":723,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":724,"generic_name":725,"generic_name_definition":726,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":588,"old_generic_name":589,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":275,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3533,"3-0296","1129","15201000","体外検査用オキシメータ","身体から採取した血液検体中の酸素濃度及びヘモグロビンを測定するために用いる光電子装置をいう。",{"id":728,"class_notification":729,"specific_maintenance_notification":730,"installation_management_notification":731,"category_code":9,"category_name":10,"subcategory_name":11,"code":732,"generic_name":733,"generic_name_definition":734,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":588,"old_generic_name":589,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":574,"company_count":574,"market_size_unit":42,"average_price_unit":42,"created_at":32},3535,"3-0298","1093","213","35470000","酵素分析装置","診断を目的とする試料中の酵素活性を測定する自動又は半自動の装置をいう。試薬及び試料を添加し、複数の試料を順次処理するために、温度調節器や付加装置を備えるものもある。酵素活性を計算するマイクロコンピュータを備えるものもあるが、測定値が条件を満たす線形を示さなかったり、他の点で条件に合わない場合もある。",{"id":736,"class_notification":737,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":738,"generic_name":739,"generic_name_definition":740,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":383,"old_generic_name":384,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":574,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3551,"3-0314","33936000","染色体分析装置","末梢血標本上の血球を示し、操作者が型による各細胞の識別を可能にする自動化装置をいう。",{"id":742,"class_notification":743,"specific_maintenance_notification":744,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":745,"generic_name":746,"generic_name_definition":747,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":383,"old_generic_name":384,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3554,"3-0317","1046","37078000","ヘモキシメトリック分析装置","溶血血液中の光の示差吸収を用いて酸素飽和度（SaO2）、酸化ヘモグロビン（HbO2）濃度、一酸化炭素ヘモグロビン（COHb）濃度、メトヘモグロビン（MetHb）濃度、及び還元ヘモグロビン（RHb）濃度を測定する装置をいう。",{"id":749,"class_notification":750,"specific_maintenance_notification":751,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":99,"code":752,"generic_name":753,"generic_name_definition":754,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":103,"old_generic_name":104,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3567,"3-0330","1017","30870000","イムノアッセイ用検体前処理装置","ヒト組織から採取した検体を均質化したり、イムノアッセイ分析装置による分析用検体の試料作製を目的とする装置又は機器をいう。",{"id":756,"class_notification":757,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":758,"generic_name":759,"generic_name_definition":760,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":531,"old_generic_name":532,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3538,"3-0301","33328000","ヘマトクリット分析装置","血液試料中のヘマトクリット（赤血球の割合）を測定する装置をいう。",{"id":762,"class_notification":763,"specific_maintenance_notification":764,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":765,"generic_name":766,"generic_name_definition":767,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":408,"old_generic_name":409,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3497,"3-0260","1088","35566000","血中カリウム分析装置","血液中のカリウムイオン（K+）濃度を測定する装置をいう。血液試料をK+センサ浸透膜に設置すると、K+は膜全体に拡散しイオン選択性電極に浸透する。その膜ポテンシャルの変化がコンピュータに出力されて、コンピュータはイオン活量を計算し濃度へ変換する。",{"id":769,"class_notification":770,"specific_maintenance_notification":771,"installation_management_notification":772,"category_code":9,"category_name":10,"subcategory_name":82,"code":773,"generic_name":774,"generic_name_definition":775,"class_classification":221,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":16,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":21,"last_updated_date":776,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":275,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},1140,"1-1142","1216","245","71059003","体細胞遺伝子変異解析システム（抗悪性腫瘍薬適応判定用）","生体由来の試料から得られた体細胞由来の遺伝子変異情報を基に、抗悪性腫瘍薬の適応判定を行うために使用される遺伝子変異解析システムをいう。DNAシークエンサー、シークエンシングサンプル調製試薬及び解析プログラムより構成され、テンプレート調製試薬等を構成品として含む場合もある。","平成31年2月6日",{"id":778,"class_notification":779,"specific_maintenance_notification":780,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":781,"generic_name":782,"generic_name_definition":783,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":588,"old_generic_name":589,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3534,"3-0297","1045","33321000","ヘパリン分析装置","試料とプロタミン（ヘパリン中和剤）を混合して空気活性化凝固の発生を光度測定法により定量することで、血液試料中のヘパリン濃度を測定する自動化装置をいう。",{"id":785,"class_notification":786,"specific_maintenance_notification":787,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":788,"generic_name":789,"generic_name_definition":790,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":260,"old_generic_name":258,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3540,"3-0303","1180","30863000","網赤血球分析装置","染色された未分化の赤血球を定量及び定性するために用いる自動又は半自動の装置をいう。ある種の造血疾病の診断を補助する。",{"id":792,"class_notification":793,"specific_maintenance_notification":794,"installation_management_notification":795,"category_code":9,"category_name":10,"subcategory_name":52,"code":796,"generic_name":797,"generic_name_definition":798,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":70,"old_generic_name":68,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3544,"3-0307","1087","212","36746000","血栓分析装置","光度測定法を用いて、血栓形成等の血液凝集又は血管での凝固の存在を測定する装置をいう。",{"id":800,"class_notification":801,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":99,"code":802,"generic_name":803,"generic_name_definition":804,"class_classification":15,"ghtf_rule":573,"specific_maintenance":16,"installation_management":42,"repair_category":16,"qms_notification":148,"old_generic_name_code":103,"old_generic_name":104,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":21,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3566,"3-0329","17106000","血清用血液分離装置","一次試料からあるタイプの血漿を分離し、分離したものを二次試料に分けるための検査装置をいう。",{"id":806,"class_notification":807,"specific_maintenance_notification":808,"installation_management_notification":809,"category_code":9,"category_name":10,"subcategory_name":11,"code":810,"generic_name":811,"generic_name_definition":812,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":813,"old_generic_name":814,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3486,"3-0249","1042","200","35745010","フロー方式臨床化学分析装置","化学物質・ヒト組織試料の定性・定量分析に用いる自動又は半自動の装置をいう。本装置では、連続的な流体の流れの中で化学反応が起こる。ターンテーブル内の試料カップから試料を設定した間隔で取り出し、試薬の流れの中に誘導する。半透膜を通して透析を行うことにより、分析物からタンパク質を分離する。流体の動きはペリスタポンプにより作られ、試薬及び試料はチューブ内を移動する。移動式のものを除く。","080202026","フロー方式臨床化学自動分析装置",{"id":816,"class_notification":817,"specific_maintenance_notification":818,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":819,"generic_name":820,"generic_name_definition":821,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":813,"old_generic_name":814,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3487,"3-0250","1015","35745020","移動式フロー方式臨床化学分析装置","化学物質・ヒト組織試料の定性・定量分析に用いる自動又は半自動の装置をいう。本装置では、連続的な流体の流れの中で化学反応が起こる。ターンテーブル内の試料カップから試料を設定した間隔で取り出し、試薬の流れの中に誘導する。半透膜を通して透析を行うことにより、分析物からタンパク質を分離する。流体の動きはペリスタポンプにより作られ、試薬及び試料はチューブ内を移動する。移動式のものをいう。",{"id":823,"class_notification":824,"specific_maintenance_notification":825,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":826,"generic_name":827,"generic_name_definition":828,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":408,"old_generic_name":409,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3499,"3-0262","1022","35937000","カルシウム分析装置","全血､血漿、血清又は尿等の液体試料中のカルシウム濃度を測定する装置をいう。カルシウムイオン選択性電極又は蛍光消光滴定法等を用いることもある。",{"id":830,"class_notification":831,"specific_maintenance_notification":832,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":833,"generic_name":834,"generic_name_definition":835,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":836,"old_generic_name":834,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3500,"3-0263","1023","35903000","クーロメトリー式電解質分析装置","全血、血漿、血清又は尿検体中の塩化物イオン濃度を測定する自動又は半自動の装置をいう。汎用分析装置に組み込まれたものと独立型のものがある。本装置は電量滴定により、臨床試料の塩化物濃度を測定する。","080206066",{"id":838,"class_notification":839,"specific_maintenance_notification":840,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":841,"generic_name":842,"generic_name_definition":843,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":844,"old_generic_name":842,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3501,"3-0264","1077","34555000","蛍光式電解質分析装置","第一鉄イオン等、特定の電解質の溶液濃度を蛍光光度法により測定する自動又は半自動の装置をいう。汎用分析装置に組み込まれたものと独立型のものがある。","080206082",{"id":846,"class_notification":847,"specific_maintenance_notification":848,"installation_management_notification":849,"category_code":9,"category_name":10,"subcategory_name":11,"code":850,"generic_name":851,"generic_name_definition":852,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":395,"old_generic_name":396,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":275,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3514,"3-0277","1182","238","70181000","粒子計測免疫測定装置","ラテックス凝集塊を光散乱を用いて計数することによって免疫学的測定を行う自動又は半自動の装置をいう。",{"id":854,"class_notification":855,"specific_maintenance_notification":856,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":857,"generic_name":858,"generic_name_definition":859,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":860,"old_generic_name":858,"old_class_classification":296,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":213,"company_count":574,"market_size_unit":42,"average_price_unit":42,"created_at":32},3517,"3-0280","1054","35885000","ラクテート分析装置","用手法で有害な過塩素酸の使用を避け、乳酸オキシダーゼ固定電極や試験紙を用いて各種生体液のラクテート（筋代謝の老廃物）濃度を測定する専用装置をいう。","080212045",{"id":862,"class_notification":863,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":864,"generic_name":865,"generic_name_definition":866,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":327,"company_count":574,"market_size_unit":42,"average_price_unit":42,"created_at":32},3520,"3-0283","15169000","検査室用屈折計","ある種の検査試料の溶質濃度を定量するために、溶液の屈折率（光屈折）の測定に用いる検査室用装置をいう。通常、臨床装置は全固形物で事前校正されているが、本装置は蛋白濃度又は比重の何れかで表示される。一般的に温度の影響を補正するように設計されている。",{"id":868,"class_notification":869,"specific_maintenance_notification":870,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":871,"generic_name":872,"generic_name_definition":873,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":574,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3524,"3-0287","1020","35989000","カテコールアミン分析装置","生物学的試料中のカテコールアミン濃度を測定する装置をいう。",{"id":875,"class_notification":876,"specific_maintenance_notification":877,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":878,"generic_name":879,"generic_name_definition":880,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":23,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":400,"company_count":21,"market_size_unit":42,"average_price_unit":42,"created_at":32},3525,"3-0288","1027","35991000","クレアチニン分析装置","尿又は血清試料中のクレアチニン濃度を測定する装置をいう。本装置は、アルカリ性物質に対する反応速度を光検出器を用いて測定し、その速度を濃度に換算する。",{"id":882,"class_notification":883,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":11,"code":884,"generic_name":885,"generic_name_definition":886,"class_classification":15,"ghtf_rule":16,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":164,"old_generic_name":165,"old_class_classification":16,"old_repair_category":88,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3527,"3-0290","37034000","ポータブル臨床用屈折計","固体・液体に当たった光の光学屈折を測定するため、臨床検査分野で用いる携帯型の機器をいう。血糖、特定の尿検体中のアルコール濃度等の測定に用いる。",{"id":888,"class_notification":889,"specific_maintenance_notification":890,"installation_management_notification":891,"category_code":9,"category_name":10,"subcategory_name":52,"code":892,"generic_name":893,"generic_name_definition":894,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":17,"repair_category":18,"qms_notification":17,"old_generic_name_code":481,"old_generic_name":479,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3547,"3-0310","1085","211","35769000","血小板凝集記録分析装置","血小板の形態及び凝集の変化を経時的に記録するために用いる自動化装置をいう。本装置は、使用する測定法（光学密度、電気インピーダンス等）に応じた血小板凝集分析装置に連結して情報を格納する。",{"id":896,"class_notification":897,"specific_maintenance_notification":898,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":52,"code":899,"generic_name":900,"generic_name_definition":901,"class_classification":15,"ghtf_rule":16,"specific_maintenance":17,"installation_management":42,"repair_category":18,"qms_notification":17,"old_generic_name_code":902,"old_generic_name":903,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3548,"3-0311","1031","70184000","セルアナライザ","血球等の細胞の生理的機能を分析する装置をいう。","080412005","セルアナライザー",{"id":905,"class_notification":906,"specific_maintenance_notification":42,"installation_management_notification":42,"category_code":9,"category_name":10,"subcategory_name":99,"code":907,"generic_name":908,"generic_name_definition":909,"class_classification":15,"ghtf_rule":573,"specific_maintenance":148,"installation_management":42,"repair_category":18,"qms_notification":148,"old_generic_name_code":910,"old_generic_name":911,"old_class_classification":15,"old_repair_category":20,"revision_count":42,"last_updated_date":42,"data_exist":397,"product_exist":397,"market_size":42,"growth_ratio":42,"average_price":42,"domestic_ratio":42,"product_count":42,"company_count":42,"market_size_unit":42,"average_price_unit":42,"created_at":32},3563,"3-0326","17123000","細胞破壊装置","検査室で細胞の内容物に接触できるよう細胞膜を分解するために用いる装置をいう。細胞膜の破壊には通常、高圧電流又は超音波衝撃波を利用する。","080804000","医用検体前処理装置の付属品"]