[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"category-devices-知覚検査又は運動機能検査用器具":3},[4,31,45,62,81,94,110,125,140,155,168,180,193,207,220,231,242,254,266,277,291,303,313,324,335,343,349,355,361,367,376,382,391,398,406,412,421,428,435,442,448,454,461,469,475,484,490,497,504,511,517,523,529,535,544,550,557,563,570,579,585,594,601,609,616,626,632,638,644,651,658,665],{"id":5,"class_notification":6,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":11,"generic_name":12,"generic_name_definition":13,"class_classification":14,"ghtf_rule":15,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":17,"old_generic_name_code":18,"old_generic_name":19,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":22,"growth_ratio":23,"average_price":24,"domestic_ratio":25,"product_count":26,"company_count":27,"market_size_unit":28,"average_price_unit":29,"created_at":30},3354,"3-0117",null,"器24","知覚検査又は運動機能検査用器具","生体電気現象検査用機器","11441001","体表面筋電計電極","体表面において、筋肉又は神経組織内の生体電気信号を検知する導体をいう。本品によって感知された電気活動を記録する一般的な装置は、筋電計（EMG）である。","Ⅰ","1","－","該当","060406046","筋電計電極","Ⅰ/Ⅱ",true,20.91,27.52,2315,86.7,73,24,"億円/年","円/個","2025-03-24T01:34:40.770687+00:00",{"id":32,"class_notification":33,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":34,"generic_name":19,"generic_name_definition":35,"class_classification":36,"ghtf_rule":37,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":16,"old_generic_name_code":18,"old_generic_name":19,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":38,"growth_ratio":39,"average_price":40,"domestic_ratio":41,"product_count":42,"company_count":43,"market_size_unit":28,"average_price_unit":44,"created_at":30},1467,"2-0264","11441002","筋肉又は神経組織内に挿入し、生体電気信号を検知する導体をいう。通常、針電極である。本品によって感知された電気活動を記録する一般的な装置は、筋電計（EMG）である。","Ⅱ","6",17.17,16.35,1.06,0,20,7,"万円/個",{"id":46,"class_notification":47,"specific_maintenance_notification":48,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":49,"generic_name":50,"generic_name_definition":51,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":54,"old_generic_name":50,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":56,"growth_ratio":57,"average_price":58,"domestic_ratio":59,"product_count":60,"company_count":61,"market_size_unit":28,"average_price_unit":44,"created_at":30},1466,"2-0263","560","11474000","筋電計","骨格筋の固有電位の測定及び記録に用いるグラフィックレコーダをいう。通常、筋障害の臨床診断において筋脱力を評価するため、また脱力が筋肉自体に関係するのか、筋肉に接続する神経の問題であるのかを判定するために用いる。","10-①","G2","060406020","特定",8.06,16.56,31.51,4.6,32,21,{"id":63,"class_notification":64,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":66,"generic_name":67,"generic_name_definition":68,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":71,"qms_notification":16,"old_generic_name_code":72,"old_generic_name":73,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":75,"growth_ratio":76,"average_price":77,"domestic_ratio":78,"product_count":79,"company_count":80,"market_size_unit":28,"average_price_unit":44,"created_at":30},1638,"2-0435","生体検査用機器","31923000","喉頭ストロボスコープ装置","咽頭内の発声現象を観察するために用いる装置をいう。通常、システムを構成する他の装置及び適切な内視鏡とともに用いる。発生装置（声門）機能の検査や発声障害の診察に用いる。","10","非該当","G5","060899992","他に分類されない生体検査用機器","☆",7.78,131.94,51.12,97.8,8,4,{"id":82,"class_notification":83,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":84,"generic_name":85,"generic_name_definition":86,"class_classification":36,"ghtf_rule":37,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":16,"old_generic_name_code":87,"old_generic_name":88,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":89,"growth_ratio":90,"average_price":91,"domestic_ratio":92,"product_count":79,"company_count":93,"market_size_unit":28,"average_price_unit":29,"created_at":30},1473,"2-0270","34374102","電気刺激装置用針電極","組織に電流を流すために用いる導体をいう。陰極と陽極の両方を備える必要がある。通常、針電極をいう。","060406088","電気刺激装置用電極",7.22,39.47,4837,45.2,5,{"id":95,"class_notification":96,"specific_maintenance_notification":97,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":99,"generic_name":100,"generic_name_definition":101,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":16,"old_generic_name_code":103,"old_generic_name":100,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":104,"growth_ratio":105,"average_price":106,"domestic_ratio":107,"product_count":108,"company_count":109,"market_size_unit":28,"average_price_unit":44,"created_at":30},2592,"2-1391","668","歯科診療室用機器","16355000","歯科用根管長測定器","電気を利用した歯科用器具で、歯内治療において根管の先端の位置を確認するために用いるものをいう。","G7","180214040",5.77,-17.33,4.76,93.1,28,15,{"id":111,"class_notification":112,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":113,"generic_name":114,"generic_name_definition":115,"class_classification":116,"ghtf_rule":117,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":87,"old_generic_name":88,"old_class_classification":20,"old_repair_category":16,"revision_count":118,"last_updated_date":119,"data_exist":120,"product_exist":21,"market_size":121,"growth_ratio":41,"average_price":122,"domestic_ratio":41,"product_count":123,"company_count":123,"market_size_unit":28,"average_price_unit":124,"created_at":30},338,"1-0338","36957003","筋肉内刺激用プローブ","刺激装置と共に使用するように特別に設計された筋肉内用プローブをいう。低侵襲手術の際に体内に挿入して神経の探知等に用いる。","Ⅲ","7,8",1,"平成28年7月28日",false,3.21,4.86,3,"万円/本",{"id":126,"class_notification":127,"specific_maintenance_notification":128,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":129,"generic_name":130,"generic_name_definition":131,"class_classification":14,"ghtf_rule":132,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":17,"old_generic_name_code":133,"old_generic_name":130,"old_class_classification":14,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":134,"growth_ratio":135,"average_price":136,"domestic_ratio":137,"product_count":138,"company_count":139,"market_size_unit":28,"average_price_unit":44,"created_at":30},4042,"3-0805","1109","70700000","歯接触分析装置","正常な口腔内に挿入するセンサを用い、何らかのエネルギーを人体に伝達することはなく、歯牙接触の位置分布、時間的順位等を測定・分析する装置をいう。咬合圧の不均衡や咬合干渉を引き起こすとされる早期接触の検査を行う。","12","180214141",2.86,12.14,1.79,1.5,19,14,{"id":141,"class_notification":142,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":143,"generic_name":144,"generic_name_definition":145,"class_classification":14,"ghtf_rule":15,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":17,"old_generic_name_code":147,"old_generic_name":144,"old_class_classification":14,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":149,"growth_ratio":150,"average_price":151,"domestic_ratio":152,"product_count":153,"company_count":154,"market_size_unit":28,"average_price_unit":44,"created_at":30},3419,"3-0182","35757000","歩行分析計","歩行又は走行パターンを試験する装置をいう。本品は、地面の反力を測定又は撮影し、膝関節、足首関節、股関節の動きを判定し、力及びトルクを測定するプラットフォームを利用する。歩行又は走行に関連した問題の診断及び矯正措置計画の支援に用いる。","G3","060808028","非特定",1.87,205.18,6.73,100,33,17,{"id":156,"class_notification":157,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":158,"generic_name":159,"generic_name_definition":160,"class_classification":14,"ghtf_rule":132,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":17,"old_generic_name_code":161,"old_generic_name":159,"old_class_classification":14,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":162,"growth_ratio":163,"average_price":164,"domestic_ratio":165,"product_count":166,"company_count":167,"market_size_unit":28,"average_price_unit":44,"created_at":30},3417,"3-0180","17242001","平衡機能計","測定台に直立した人体の重心の位置と動きを表示し、定量解析を行う機器をいう。","060806109",1.76,-29.06,136.91,96.2,16,9,{"id":169,"class_notification":170,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":171,"generic_name":172,"generic_name_definition":173,"class_classification":14,"ghtf_rule":15,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":17,"old_generic_name_code":87,"old_generic_name":88,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":174,"growth_ratio":175,"average_price":176,"domestic_ratio":177,"product_count":178,"company_count":179,"market_size_unit":28,"average_price_unit":29,"created_at":30},3356,"3-0119","34374001","体表面電気刺激装置用電極","組織に電流を流すため、体表面に用いる導体をいう。陰極と陽極の両方を備える必要がある。",1.35,29.14,792,1.2,41,18,{"id":181,"class_notification":182,"specific_maintenance_notification":183,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":184,"generic_name":185,"generic_name_definition":186,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":16,"old_generic_name_code":187,"old_generic_name":185,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":188,"growth_ratio":189,"average_price":190,"domestic_ratio":191,"product_count":166,"company_count":192,"market_size_unit":28,"average_price_unit":44,"created_at":30},2595,"2-1394","664","70698000","歯科用下顎運動測定器","顎関節の異常を診断するために下顎運動を電気的に測定する機器をいう。運動経路の解析の他、顎関節音、筋電位等の測定に用いることがある。","180214109",1.13,-44.71,112.02,86,11,{"id":194,"class_notification":195,"specific_maintenance_notification":196,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":197,"generic_name":198,"generic_name_definition":199,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":200,"old_generic_name":201,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":202,"growth_ratio":203,"average_price":204,"domestic_ratio":205,"product_count":167,"company_count":206,"market_size_unit":28,"average_price_unit":44,"created_at":30},1468,"2-0265","861","32516000","電気誘発反応刺激装置","誘発反応の測定を目的として皮膚電極によって電気刺激を供給するために用いる装置をいう。","060406062","電気刺激装置",0.95,-30.7,93.73,10.5,6,{"id":208,"class_notification":209,"specific_maintenance_notification":210,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":211,"generic_name":212,"generic_name_definition":213,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":16,"old_generic_name_code":214,"old_generic_name":215,"old_class_classification":16,"old_repair_category":74,"revision_count":118,"last_updated_date":216,"data_exist":21,"product_exist":21,"market_size":217,"growth_ratio":218,"average_price":219,"domestic_ratio":41,"product_count":80,"company_count":123,"market_size_unit":28,"average_price_unit":44,"created_at":30},2599,"2-1398","676","70701000","歯牙動揺測定器","歯に振動を加え、動揺の程度を電気的に測定する機器をいう。特定の歯に対する異常な荷重負担又は歯周疾患の重症度を検出することができる。","180214994","その他の歯科電気診断用機器","平成23年3月31日",0.89,-16.63,18.52,{"id":221,"class_notification":222,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":223,"generic_name":224,"generic_name_definition":225,"class_classification":36,"ghtf_rule":226,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":16,"old_generic_name_code":87,"old_generic_name":88,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":227,"growth_ratio":228,"average_price":229,"domestic_ratio":230,"product_count":43,"company_count":80,"market_size_unit":28,"average_price_unit":124,"created_at":30},1474,"2-0271","36957002","皮下刺激用プローブ","刺激装置と共に使用するように特別に設計された皮下用プローブをいう。","6,6-①",0.88,-17.64,2.57,44.1,{"id":232,"class_notification":233,"specific_maintenance_notification":234,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":235,"generic_name":236,"generic_name_definition":237,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":200,"old_generic_name":201,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":238,"growth_ratio":239,"average_price":240,"domestic_ratio":241,"product_count":167,"company_count":206,"market_size_unit":28,"average_price_unit":44,"created_at":30},1471,"2-0268","728","35729000","診断用神経筋電気刺激装置","刺激装置の1種で、ある末梢領域の反応を監視しながら、身体の別の末梢領域を刺激するものをいう。通常、治療に用いる神経筋刺激装置よりも設計及び機能が単純である。非常に限定された部位を刺激するため、外部電極（手持型双極性電極、リング電極、針電極等）を用いるものが多い。臨床電気生理学的評価時に実施する運動神経伝導試験（後脛骨神経等）又は感覚神経伝導試験（尺骨神経等）において、末梢神経又は筋肉の刺激に用いる。",0.81,25.75,20.07,44.5,{"id":243,"class_notification":244,"specific_maintenance_notification":245,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":246,"generic_name":247,"generic_name_definition":248,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":16,"old_generic_name_code":249,"old_generic_name":250,"old_class_classification":36,"old_repair_category":55,"revision_count":118,"last_updated_date":216,"data_exist":21,"product_exist":21,"market_size":251,"growth_ratio":252,"average_price":253,"domestic_ratio":41,"product_count":93,"company_count":80,"market_size_unit":28,"average_price_unit":44,"created_at":30},2591,"2-1390","860","13187000","電気式歯髄診断器","電気式歯髄診断器で、電極から高周波電流を加えて歯髄の神経組織を刺激することによって歯髄の疼痛反応をみるものをいう。","180214024","歯髄診断器",0.68,32.64,6.44,{"id":255,"class_notification":256,"specific_maintenance_notification":257,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":258,"generic_name":259,"generic_name_definition":260,"class_classification":116,"ghtf_rule":261,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":264,"growth_ratio":41,"average_price":265,"domestic_ratio":41,"product_count":93,"company_count":80,"market_size_unit":28,"average_price_unit":44,"created_at":30},351,"1-0351","193","35723003","神経探知刺激装置","神経と手術器具（メス等）との位置関係を監視するため神経を断続的に探知する装置をいう。筋弛緩剤又は麻酔薬投与量の判定に用いられることがある。神経刺激装置と神経の信号活動を記録する受信器から構成される。","10-④","060806994","その他の知覚検査用機器",0.46,36.31,{"id":267,"class_notification":268,"specific_maintenance_notification":269,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":270,"generic_name":271,"generic_name_definition":272,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":200,"old_generic_name":201,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":273,"growth_ratio":41,"average_price":274,"domestic_ratio":275,"product_count":276,"company_count":123,"market_size_unit":28,"average_price_unit":44,"created_at":30},1472,"2-0269","727","35974000","診断用心臓電気刺激装置","自発調律及びペーシング時に、心臓に正確なタイミングで電気インパルスを供給するプログラム可能な刺激装置をいう。様々な強度の刺激を供給するため非同期又は同期モードで使用することができる。ペーシングには、広範囲の周期長（通常、150～1500ms）で用いることができる。心臓の生理学的検査、例えば、房室伝導の各種成分の機能の判定、頻脈の誘発及び停止に必要な因子、洞結節機能の評価等の実施に用いる。",0.32,264.15,43.8,2,{"id":278,"class_notification":279,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":280,"generic_name":281,"generic_name_definition":282,"class_classification":14,"ghtf_rule":15,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":70,"old_generic_name_code":283,"old_generic_name":284,"old_class_classification":14,"old_repair_category":148,"revision_count":118,"last_updated_date":285,"data_exist":21,"product_exist":21,"market_size":286,"growth_ratio":287,"average_price":288,"domestic_ratio":289,"product_count":290,"company_count":61,"market_size_unit":28,"average_price_unit":44,"created_at":30},3421,"3-0184","12950001","手動式皮膚痛覚計","患者の痛みに関する感受性（ピンによる刺傷等）を測定するために用いる手動式装置をいう。痛覚計ともいう。","060808060","圧痛覚計","平成28年10月19日",0.28,17.23,1.65,1.7,27,{"id":292,"class_notification":293,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":294,"generic_name":295,"generic_name_definition":296,"class_classification":14,"ghtf_rule":15,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":70,"old_generic_name_code":297,"old_generic_name":295,"old_class_classification":14,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":298,"growth_ratio":299,"average_price":300,"domestic_ratio":301,"product_count":302,"company_count":302,"market_size_unit":28,"average_price_unit":29,"created_at":30},3424,"3-0187","37529000","角度計","X線又は手術時等に骨の角度を測定するために用いる器具をいう。通常、分度器として知られている。","060808086",0.22,-44.33,9084,99.4,25,{"id":304,"class_notification":305,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":306,"generic_name":307,"generic_name_definition":308,"class_classification":14,"ghtf_rule":15,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":70,"old_generic_name_code":309,"old_generic_name":307,"old_class_classification":14,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":310,"growth_ratio":311,"average_price":312,"domestic_ratio":152,"product_count":206,"company_count":206,"market_size_unit":28,"average_price_unit":29,"created_at":30},3420,"3-0183","35021000","握力計","患者の手・前腕の筋強度を測定、検査、調節する装置をいう。通常、脳卒中後のリハビリテーションに用いる。","060808044",0.18,20.74,8398,{"id":314,"class_notification":315,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":316,"generic_name":317,"generic_name_definition":318,"class_classification":36,"ghtf_rule":52,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":319,"old_generic_name":320,"old_class_classification":36,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":321,"growth_ratio":322,"average_price":323,"domestic_ratio":152,"product_count":80,"company_count":123,"market_size_unit":28,"average_price_unit":44,"created_at":30},1601,"2-0398","37349000","神経疾患診断用定量的感覚検査器","身体のある部分の皮膚の振動覚閾値を測定するために必要な振動レベルを検査及び判定するために用いる装置をいう。神経病理学的診断に用い、糖尿病の疑い、神経毒性物質（溶剤、重金属等）への暴露、劣悪な労働環境、交通事故等の障害の初期症状を発見するために使用する。","060806024","振動感覚測定装置",0.13,-20,81.7,{"id":325,"class_notification":326,"specific_maintenance_notification":327,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":328,"generic_name":329,"generic_name_definition":330,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":118,"last_updated_date":331,"data_exist":21,"product_exist":21,"market_size":332,"growth_ratio":333,"average_price":334,"domestic_ratio":41,"product_count":123,"company_count":123,"market_size_unit":28,"average_price_unit":44,"created_at":30},1623,"2-0420","558","37042000","局所麻酔用神経刺激装置","局所麻酔の前に身体のある部位における適切な神経を探知するために用いる電池電源式の装置をいう。この領域を電流で刺激することによって、筋反射が活性化され、観察することができる。局所麻酔を目的とした麻酔薬等の注射後、電流を増大させることによって筋反射を確認することもできる。本品は、理学療法や診断目的にも用いられる。","平成24年3月1日",0.09,-24.92,3.51,{"id":336,"class_notification":337,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":338,"generic_name":339,"generic_name_definition":340,"class_classification":14,"ghtf_rule":15,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":70,"old_generic_name_code":297,"old_generic_name":295,"old_class_classification":14,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":21,"product_exist":21,"market_size":41,"growth_ratio":341,"average_price":41,"domestic_ratio":41,"product_count":342,"company_count":342,"market_size_unit":28,"average_price_unit":29,"created_at":30},3423,"3-0186","36148000","関節運動テスタ","関節の特性を評価するために用いる装置をいう。通常、評価は異常のある関節に対する手術（関節置換術、関節鏡下処置等）の前後に実施される。関節可動域及び正常機能を評価する。",-100,10,{"id":344,"class_notification":345,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":346,"generic_name":347,"generic_name_definition":348,"class_classification":36,"ghtf_rule":52,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":118,"last_updated_date":216,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":123,"company_count":276,"market_size_unit":7,"average_price_unit":7,"created_at":30},1625,"2-0422","38826000","温度覚用定量的感覚検査機器","温度覚の障害部分を判定するために使用する迅速検査用の機器をいう。予め設定した温度（例、25℃及び49℃）に加熱された帯電ローラを適用することによって検査が行われる（正常皮膚温度は30－32℃）。患者が対応する感覚を識別し、感覚が正常・異常な部位をマッピングする。",{"id":350,"class_notification":351,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":352,"generic_name":353,"generic_name_definition":354,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":118,"last_updated_date":331,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},1626,"2-0423","70099000","単回使用神経ロケータ","外科手術で、運動神経の識別若しくは位置確認又は筋肉反応検査に用いる単回使用神経ロケータをいう。皮下に穿刺する針電極、皮膚組織に接触させる探査電極、電気的導通を確認するためのパイロットランプ等から構成される。",{"id":356,"class_notification":357,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":358,"generic_name":359,"generic_name_definition":360,"class_classification":36,"ghtf_rule":52,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},1627,"2-0424","70100000","電気味覚計","味覚検査に用いる機器をいう。電極を舌に接触させて電流刺激を行い、味覚を感じる電流閾値を測定する。",{"id":362,"class_notification":363,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":364,"generic_name":365,"generic_name_definition":366,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":16,"old_generic_name_code":283,"old_generic_name":284,"old_class_classification":14,"old_repair_category":148,"revision_count":118,"last_updated_date":285,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1629,"2-0426","12950002","電動式皮膚痛覚計","患者の痛みに関する感受性（ピンによる刺傷等）を測定するために用いる電動式装置をいう。痛覚計ともいう。",{"id":368,"class_notification":369,"specific_maintenance_notification":370,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":371,"generic_name":372,"generic_name_definition":373,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":374,"old_generic_name":375,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":276,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},1630,"2-0427","762","17929000","生理学的神経筋機能分析装置","脊椎分析又は関節運動検査等、身体の図形表示及び生体工学的分析の目的で、身体又は関節の運動を測定し、評価するために用いる装置をいう。運動失調（筋肉協調運動不能）の程度を測定するために用いることもできる。本品は通常、スポーツ、仕事、リハビリテーションにかかわるメカニズム・タスクの検査に用いる。光電子工学又は電磁気を利用した装置、マーカー、センサー、ビデオカメラ、画像処理機及びコンピュータ等さまざまなコンポーネントを含むものもある。","060808998","その他の運動機能検査用機器",{"id":377,"class_notification":378,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":379,"generic_name":380,"generic_name_definition":381,"class_classification":36,"ghtf_rule":52,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":374,"old_generic_name":375,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1631,"2-0428","12692000","ミオグラフ","筋収縮の強度又は速度といった様々な相を判定及び記録する装置をいう。筋収縮に関連した変位又は力を検出し、グラフ（筋運動図）に再現するセンサを内蔵している。緊張持続下での変位又は等尺性条件下で発現する力といったいくつかの条件下での筋肉の評価に用いる。",{"id":383,"class_notification":384,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":385,"code":386,"generic_name":387,"generic_name_definition":388,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":16,"old_generic_name_code":389,"old_generic_name":390,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1810,"2-0607","その他の生体現象計測・監視システム","17442000","勃起トランスデューサ","勃起を検出し、親機に関連測定値を表示・処理する装置をいう。","069999000","他に分類されない生体現象計測・監視システム",{"id":392,"class_notification":393,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":394,"generic_name":395,"generic_name_definition":396,"class_classification":14,"ghtf_rule":15,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":70,"old_generic_name_code":397,"old_generic_name":395,"old_class_classification":14,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":276,"company_count":276,"market_size_unit":7,"average_price_unit":7,"created_at":30},3425,"3-0188","34395000","背筋力計","力（特に背筋の屈曲によって生じる筋力）を測定するために用いる機器・装置をいう。通常、リハビリテーションのため、筋強度の管理に用いる。","060808103",{"id":399,"class_notification":400,"specific_maintenance_notification":401,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":402,"generic_name":403,"generic_name_definition":404,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":16,"old_generic_name_code":405,"old_generic_name":403,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},2593,"2-1392","675","70696000","歯科用咬合音測定器","下顎運動時に咬合音（振動）を電気的に測定する機器をいう。咬合干渉を引き起こすとされる早期接触の検査を行う。","180214066",{"id":407,"class_notification":408,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":409,"generic_name":410,"generic_name_definition":411,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":102,"qms_notification":16,"old_generic_name_code":214,"old_generic_name":215,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":276,"company_count":276,"market_size_unit":7,"average_price_unit":7,"created_at":30},2597,"2-1396","33995020","光学式う蝕検出装置","う蝕の検出装置をいう。この装置はう蝕の検出に関して光学的性質を利用する。",{"id":413,"class_notification":414,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":415,"code":416,"generic_name":417,"generic_name_definition":418,"class_classification":14,"ghtf_rule":132,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":70,"old_generic_name_code":419,"old_generic_name":420,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},3343,"3-0106","生体物理現象検査用機器","32546000","振せんトランスデューサ","ある種の疾患によって生じる振せんの程度を測定するために用いる装置をいう。","060299996","他に分類されない生体物理現象検査用機器",{"id":422,"class_notification":423,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":424,"generic_name":425,"generic_name_definition":426,"class_classification":14,"ghtf_rule":15,"specific_maintenance":70,"installation_management":7,"repair_category":427,"qms_notification":70,"old_generic_name_code":297,"old_generic_name":295,"old_class_classification":14,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},3422,"3-0185","35408000","捻転角度計","眼球又は長骨の軸などの捻転の程度を測定する器械をいう。","G4",{"id":429,"class_notification":430,"specific_maintenance_notification":431,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":432,"generic_name":433,"generic_name_definition":434,"class_classification":14,"ghtf_rule":132,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":17,"old_generic_name_code":214,"old_generic_name":215,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},4044,"3-0807","1106","70702000","歯科用顎関節音測定器","口腔外に設置するマクロフォン等により、下顎運動時の顎関節音を測定する機器をいう。円滑な顎関節の運動を妨げる関節付近の軟組織、例えば、関節円板の異常な挙動を検出することができる。",{"id":206,"class_notification":436,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":437,"generic_name":438,"generic_name_definition":439,"class_classification":440,"ghtf_rule":441,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":16,"old_generic_name_code":87,"old_generic_name":88,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},"1-0006","36957004","心臓・中枢神経刺激用プローブ","刺激装置と共に使用するように特別に設計された心臓・中枢神経用プローブをいう。","Ⅳ","8-②",{"id":443,"class_notification":444,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":445,"generic_name":446,"generic_name_definition":447,"class_classification":36,"ghtf_rule":69,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":16,"old_generic_name_code":374,"old_generic_name":375,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},1635,"2-0432","70102000","十字靭帯機能検査機器","十字靭帯機能の評価を行う器具をいう。",{"id":449,"class_notification":450,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":451,"generic_name":452,"generic_name_definition":453,"class_classification":14,"ghtf_rule":15,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":70,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},4449,"3-1212","71093001","咀嚼能力検査用物質","咀嚼能力の検査に用いる標準物質をいう。例えば、患者が本品を咀嚼し、その後吐出した粒子数等を計測することで、咀嚼能力を検査する。吐出物を撮影するためのカメラ及び粒子数を測定するためのプログラムを含むこともある。",{"id":455,"class_notification":456,"specific_maintenance_notification":457,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":458,"generic_name":459,"generic_name_definition":460,"class_classification":14,"ghtf_rule":132,"specific_maintenance":17,"installation_management":70,"repair_category":102,"qms_notification":17,"old_generic_name_code":16,"old_generic_name":16,"old_class_classification":16,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},4452,"3-1215","1238","71100001","歯科用硬組織硬度測定器","口腔内に挿入するセンサを用い、何らかのエネルギーを人体に伝達することはなく、歯の硬組織の硬度を測定する機器をいう。硬度の測定に関して光学的原理を利用するものもある。",{"id":462,"class_notification":463,"specific_maintenance_notification":464,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":465,"generic_name":466,"generic_name_definition":467,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":16,"old_generic_name_code":468,"old_generic_name":466,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":123,"company_count":276,"market_size_unit":7,"average_price_unit":7,"created_at":30},2594,"2-1393","677","70697000","歯周ポケット測定器","歯周ポケットの深さを電気的に測定する機器をいう。","180214082",{"id":470,"class_notification":471,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":472,"generic_name":473,"generic_name_definition":474,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},1628,"2-0425","70101000","眼球運動刺激装置","平衡機能障害の度合いを計測するため、視刺激により前庭神経などの平衡神経系を刺激し、前庭眼反射による眼球運動を誘発するために用いる装置をいう。",{"id":476,"class_notification":477,"specific_maintenance_notification":478,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":98,"code":479,"generic_name":480,"generic_name_definition":481,"class_classification":14,"ghtf_rule":132,"specific_maintenance":17,"installation_management":7,"repair_category":102,"qms_notification":17,"old_generic_name_code":482,"old_generic_name":483,"old_class_classification":14,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":80,"company_count":123,"market_size_unit":7,"average_price_unit":7,"created_at":30},4041,"3-0804","1108","70699000","歯科用咬合力計","正常な口腔内に挿入するセンサを用い、何らかのエネルギーを人体に伝達することはなく、上下歯牙の咬合力（圧）を測定する機器をいう。顎関節症等の神経筋機能障害による咬合圧の分布異常や不均衡を検出することができる。","180214125","歯科用咬合力（圧）計",{"id":485,"class_notification":486,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":487,"generic_name":488,"generic_name_definition":489,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":72,"old_generic_name":73,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":276,"company_count":276,"market_size_unit":7,"average_price_unit":7,"created_at":30},1641,"2-0438","70103000","発声機能検査装置","発声強度、基本周波数、呼気流量等の物理量を観測又は記録する機器で、発声器官の機能障害の診断に用いるものをいう。これらの物理量の相互関係や安定度を測定する機能を含むものもある。",{"id":491,"class_notification":492,"specific_maintenance_notification":493,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":494,"generic_name":495,"generic_name_definition":496,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":200,"old_generic_name":201,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":80,"company_count":276,"market_size_unit":7,"average_price_unit":7,"created_at":30},1470,"2-0267","785","35726000","体性感覚誘発神経電気刺激装置","末梢神経電気刺激装置の1種で、末梢神経を正確なタイミングで反復して刺激するために用いるものをいう。通常、外部表面電極又は侵襲電極（針電極）を用いるマルチチャンネル体外型刺激装置である。本品は、誘発電位検査及びその他の研究（てんかんの機能的マッピング等）に用いる。より複雑な装置（体性感覚誘発電位レコーダ等）のコンポーネントとなるものもある。",{"id":498,"class_notification":499,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":500,"generic_name":501,"generic_name_definition":502,"class_classification":14,"ghtf_rule":503,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":17,"old_generic_name_code":72,"old_generic_name":73,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},3429,"3-0192","14288000","尿道計","尿道に挿入し、尿道を拡張させ、その拡張程度を示す測定値を得るために用いる専用装置をいう。通常、測定値はダイヤルに表示される。","5-①",{"id":505,"class_notification":506,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":507,"generic_name":508,"generic_name_definition":509,"class_classification":116,"ghtf_rule":510,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":16,"old_generic_name_code":87,"old_generic_name":88,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},337,"1-0337","34374203","ヘパリン使用体表面電気刺激装置用電極","組織に電流を流すため、体表面に用いるヘパリン使用導体をいう。陰極と陽極の両方を備える必要がある。","1,14",{"id":512,"class_notification":513,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":514,"generic_name":515,"generic_name_definition":516,"class_classification":36,"ghtf_rule":52,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1620,"2-0417","35056000","触覚用定量的感覚検査器","神経学的検査で、皮膚の感受性が正常な部分と亢進又は低下した部分を調べたり、触覚閾値を測定するために用いる装置をいう。検査は以下のような様々な方法で行われる：1.感覚が生じるまで、各種直径の人工毛を適用する；2.1本のロッド又はファイバ（触覚の正常・異常を検査する人の指に固定する）を用いる；3.ピンホイール（回転鋸状ホイール）を用い、皮膚上を移動させる；4.異常部を判別するために1つの先のとがった器具で刺激したり、コンパス様の器具で中心点から徐々に弧が大きくなるよう描写する。",{"id":518,"class_notification":519,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":520,"generic_name":521,"generic_name_definition":522,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":16,"old_generic_name_code":374,"old_generic_name":375,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1632,"2-0429","32686000","会陰圧測定器","外部の圧力計に接続された膣に挿入する液体入りの袋からなる器具をいう。会陰筋の自発的収縮に抵抗することによって、会陰筋の強度を測定し、運動を通して尿失禁又は性機能不全を診断及び治療するのに用いる。",{"id":524,"class_notification":525,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":526,"generic_name":527,"generic_name_definition":528,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":16,"old_generic_name_code":374,"old_generic_name":375,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1634,"2-0431","40817000","定量的感覚検査用パルポメータ","障害の疑いがある患者に対して痛覚知覚の閾値を検査、判定する装置をいう。いくつかの測定技術を利用して機能するものもある。通常、圧痛閾値と呼ばれる反射逃避反応の初期相を検出する。",{"id":530,"class_notification":531,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":532,"generic_name":533,"generic_name_definition":534,"class_classification":36,"ghtf_rule":69,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":16,"old_generic_name_code":72,"old_generic_name":73,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},1642,"2-0439","70104000","舌圧測定器","舌圧を電気的に測定するための用具をいう。",{"id":536,"class_notification":537,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":538,"code":539,"generic_name":540,"generic_name_definition":541,"class_classification":36,"ghtf_rule":542,"specific_maintenance":70,"installation_management":7,"repair_category":71,"qms_notification":16,"old_generic_name_code":543,"old_generic_name":538,"old_class_classification":16,"old_repair_category":74,"revision_count":118,"last_updated_date":216,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},2912,"2-1711","その他の眼科用品及び関連製品","70974000","角膜知覚計","ナイロンフィラメントを角膜に当てて、角膜の知覚感度を測定する器械をいう。","5-①'","249900006",{"id":545,"class_notification":546,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":547,"generic_name":548,"generic_name_definition":549,"class_classification":14,"ghtf_rule":15,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":17,"old_generic_name_code":87,"old_generic_name":88,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},3355,"3-0118","43441000","再使用可能な体表面電気刺激装置用電極","組織に電流を流すために電気刺激装置とともに使用する、体表面に用いる電極をいう。陰極と陽極の両方を備える必要がある。本品は適切に洗浄したのちに再使用することができる。",{"id":551,"class_notification":552,"specific_maintenance_notification":553,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":554,"generic_name":555,"generic_name_definition":556,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1621,"2-0418","866","35169000","電磁刺激装置","刺激装置の1種で、患者の熱知覚閾値未満のレベルで組織に電磁エネルギーを供給するものをいう。通常、短時間パルス高周波エネルギーを利用して標的組織の温度を1℃未満上昇させる。",{"id":558,"class_notification":559,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":415,"code":560,"generic_name":561,"generic_name_definition":562,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":146,"qms_notification":16,"old_generic_name_code":419,"old_generic_name":420,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},1430,"2-0227","33890000","ポータブル勃起データレコーダ","陰茎の勃起（勃起傾向）を監視する装置をいう。患者が携行し、勃起機能（長さ、太さ、持続時間等）を記録する。記録されたデータを陰茎機能不全（インポテンス等）の診断に用いる。",{"id":564,"class_notification":565,"specific_maintenance_notification":566,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":567,"generic_name":568,"generic_name_definition":569,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":200,"old_generic_name":201,"old_class_classification":36,"old_repair_category":55,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1469,"2-0266","542","35724000","顔面神経刺激装置","顔面麻痺（ベル麻痺等）の診断及び臨床評価時、又は外科処置による顔面神経損傷時に、顔面神経の残存性を検査するために用いる装置をいう。神経支配に無関係な筋収縮を検査する機能を備えるものもある。本品は、顔面手術時に露出した組織下にある神経を探知し、顔面神経の偶発的な損傷を防止するのに有用である。",{"id":571,"class_notification":572,"specific_maintenance_notification":573,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":574,"generic_name":575,"generic_name_definition":576,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":577,"old_generic_name":578,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1475,"2-0272","562","36728000","筋電用増幅器","筋電計（EMG）で用いる増幅器をいう。本群は旧来の技術を反映していることがある。","060406990","その他の筋電計及び関連機器",{"id":580,"class_notification":581,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":582,"generic_name":583,"generic_name_definition":584,"class_classification":14,"ghtf_rule":15,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":17,"old_generic_name_code":87,"old_generic_name":88,"old_class_classification":20,"old_repair_category":16,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":276,"company_count":276,"market_size_unit":7,"average_price_unit":7,"created_at":30},3357,"3-0120","36957001","体表面刺激用プローブ","刺激装置と共に使用するように特別に設計された体表面用プローブをいう。",{"id":586,"class_notification":587,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":588,"generic_name":589,"generic_name_definition":590,"class_classification":36,"ghtf_rule":591,"specific_maintenance":16,"installation_management":7,"repair_category":16,"qms_notification":16,"old_generic_name_code":592,"old_generic_name":593,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1481,"2-0278","11436000","膀胱用電極","診断検査を目的として、膀胱と接触させて設置し、膀胱を刺激してその電気活動を記録する導体をいう。","5-⑥","060408994","その他の生体現象データ処理装置及び関連機器",{"id":595,"class_notification":596,"specific_maintenance_notification":597,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":598,"generic_name":599,"generic_name_definition":600,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":592,"old_generic_name":593,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1482,"2-0279","345","16034000","エレクトログロットグラフ","呼吸及び発生時の声帯の運動により生じる電位又はインピーダンスの変化を記録するために用いるグラフィックレコーダをいう。適切なセンサが利用される。発生障害の治療において声帯閉塞の程度を評価するため及び咽頭機構の試験に用いる。",{"id":602,"class_notification":603,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":604,"generic_name":605,"generic_name_definition":606,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":71,"qms_notification":16,"old_generic_name_code":607,"old_generic_name":608,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1489,"2-0286","11480000","眼電位計","視覚刺激に対する眼球運動時の網膜と角膜間の電位差の記録を目的とした機器をいう。例えば、内外両眼角部につける表面電極と、生体電位を増幅する増幅器を用いるものがある。波形の保存及び分析のためにパーソナルコンピュータを内蔵又は接続できるものもある。特定の網膜疾患の診断に明暗順応の評価等で用いることがある。読書及び睡眠時の眼の微細な速い動きを記録する能力を備えたものもある。眼球運動の記録に用いられることがある。","060499996","他に分類されない生体電気現象検査用機器",{"id":610,"class_notification":611,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":10,"code":612,"generic_name":613,"generic_name_definition":614,"class_classification":36,"ghtf_rule":615,"specific_maintenance":70,"installation_management":7,"repair_category":427,"qms_notification":16,"old_generic_name_code":607,"old_generic_name":608,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1491,"2-0288","35722000","ブロックモニタ用末梢神経電気刺激装置","末梢神経電気刺激装置の1種で、手術時の神経筋ブロック（尺骨神経、顔面神経、下肢神経等）の適切性と回復期における神経筋ブロックの消失を評価するために神経を刺激するものをいう。電池電源式又はライン電源式であり、通常、トゥイッチ、トレイン・オブ・フォー、テタニー、ダブルバーストという4種類の刺激形式を使用する。通常、従来の心電図電極又は双極表面電極（ボール電極）を利用する。","9",{"id":617,"class_notification":618,"specific_maintenance_notification":619,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":620,"code":621,"generic_name":622,"generic_name_definition":623,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":624,"old_generic_name":625,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1560,"2-0357","838","生体現象監視用機器","36252000","長時間身体活動データレコーダ","患者の1日の運動を長時間にわたり測定及び記録する自動装置をいう。通常、患者の肢に取り付けて患者が携行し、通常の日常活動を行わせる。身体運動がトランスデューサで検出され、信号が計数及び計時回路に送信される。運動は数日にわたって記録し、後にコンピュータソフトウェアを用いて解析される。本品のアプリケーションとして、心不全患者の健康状態、日常活動、運動能力を評価するものがある。","060699990","他に分類されない生体現象監視用機器",{"id":627,"class_notification":628,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":629,"generic_name":630,"generic_name_definition":631,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":319,"old_generic_name":320,"old_class_classification":36,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1600,"2-0397","14144000","振せん描画器","不随意の揺れ又は震え（振せん）を記録する装置をいう。様々な安静位置にある指、手、腕の動きを感知するセンサを内蔵している。動きは、記録ペン又は電気トランスデューサ（高感度の記録の場合）を用いて直接記録される。",{"id":633,"class_notification":634,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":635,"generic_name":636,"generic_name_definition":637,"class_classification":36,"ghtf_rule":69,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":161,"old_generic_name":159,"old_class_classification":14,"old_repair_category":148,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1616,"2-0413","17242002","平衡機能検査システム","センサとともにコンピュータ及び専用ソフトウェアを備えた傾斜バランスのプラットフォームを利用し、患者の平衡機能を検査するためのシステムをいう。患者は医師の指示又はプラットフォームの不安定化に応じて重心を調節する（一方に傾く）。このような運動のアウトプットを測定し、コンピュータに記録して図式的に再現する。本品は姿勢検査、バランス又は平衡感覚の検査等に用いる。",{"id":639,"class_notification":640,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":641,"generic_name":642,"generic_name_definition":643,"class_classification":36,"ghtf_rule":52,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1617,"2-0414","12796000","定量的感覚検査用嗅覚計","患者の嗅覚の定量的及び定性的評価に用いる装置をいう。各種のにおいが入った小瓶のラックや、スライド式の試験管装置等様々な構成のものがある。通常、患者の嗅覚が変化する可能性のある頭部外傷後に用いる。",{"id":645,"class_notification":646,"specific_maintenance_notification":647,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":648,"generic_name":649,"generic_name_definition":650,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":118,"last_updated_date":216,"data_exist":120,"product_exist":21,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":118,"company_count":118,"market_size_unit":7,"average_price_unit":7,"created_at":30},1619,"2-0416","766","34891000","前庭機能熱刺激装置","刺激装置の1種で、外耳道内に気流又は水流として熱刺激を供給するものをいう。前庭機能刺激装置は、媒体の流速及び温度を調節するためポンプ、バルブ、ヒータ、レギュレータを内蔵する灌流システムからなる。半規管への刺激は、眼振計で測定される不随意な眼の動きを誘発させる。患者の平衡機能系を評価することによって、前庭機能の検査に用いる。",{"id":652,"class_notification":653,"specific_maintenance_notification":654,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":655,"generic_name":656,"generic_name_definition":657,"class_classification":36,"ghtf_rule":69,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1618,"2-0415","388","14069000","トノスコープ","スクリーン上に振動を記録することにより音を視覚化するために用いる器具をいう。音による頭部又は脳の検査に用いる。",{"id":659,"class_notification":660,"specific_maintenance_notification":661,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":662,"generic_name":663,"generic_name_definition":664,"class_classification":36,"ghtf_rule":52,"specific_maintenance":17,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1622,"2-0419","470","35723002","位置決定用神経探知刺激装置","神経と手術器具（メス等）との位置関係を監視するため神経を断続的に探知する装置をいう。神経刺激装置と神経の信号活動を記録する受信器から構成される。",{"id":666,"class_notification":667,"specific_maintenance_notification":7,"installation_management_notification":7,"category_code":8,"category_name":9,"subcategory_name":65,"code":668,"generic_name":669,"generic_name_definition":670,"class_classification":36,"ghtf_rule":52,"specific_maintenance":70,"installation_management":7,"repair_category":53,"qms_notification":16,"old_generic_name_code":262,"old_generic_name":263,"old_class_classification":16,"old_repair_category":74,"revision_count":7,"last_updated_date":7,"data_exist":120,"product_exist":120,"market_size":7,"growth_ratio":7,"average_price":7,"domestic_ratio":7,"product_count":7,"company_count":7,"market_size_unit":7,"average_price_unit":7,"created_at":30},1624,"2-0421","37350000","定量的感覚検査用温度分析装置","温冷感覚閾値に関する情報を得るため、熱刺激に対する反応（通常、皮膚表面における反応）を定量的に診断評価する装置をいう。侵襲的又は非侵襲的装置がある。初期糖尿病、幻想痛の発見、細神経線維系の神経学的試験等の診断検査及び疼痛閾値の検査に用いる。検査は温度を約42－50℃に上昇させることによって行われる。"]