FDA Warning Letter

Laboratorios Jaloma S.A. de C.V.

Finished Pharmaceuticals/Unapproved New Drug/Misbranded/Adulterated

発出済み(対応中)医薬品
発出日
2021.01.25
掲載日
2021.01.26
発行オフィス
Center for Drug Evaluation and Research | CDER
MARCS-CMS 番号
609287
配達方法
VIA UPS
宛先
Mr. Jaime Labastida

本文(英語原文)


Delivery Method:
VIA UPS
Product:
Drugs

Recipient:
Recipient Name
Mr. Jaime Labastida
Recipient Title
Director
Laboratorios Jaloma S.A. de C.V.

Calle Aquiles Serdan No. 438
Col. Oblatos
44700 Guadalajara, Jal.
Mexico

Issuing Office:
Center for Drug Evaluation and Research | CDER

United States


Warning Letter 320-21-17

January 25, 2021

Dear Mr. Labastida:

Your firm is registered as a human drug manufacturer. The U.S. Food and Drug Administration (FDA) conducted testing of a consumer antiseptic rub drug product (also referred to as a consumer hand sanitizer) labeled as Jaloma Antiseptic Hand Sanitizer. This drug product was declared to be manufactured at your facility, Laboratorios Jaloma S.A. de C.V., FEI 3002600322, at Calle Aquiles Serdan No. 438, Col. Oblatos, Guadalajara, Jalisco. Following an attempt to import Jaloma Antiseptic Hand Sanitizer into the United States, it was detained and refused admission at the border.

The results of the FDA laboratory testing of a batch of this product detained at the border demonstrate that this drug product declared to be manufactured at your facility is adulterated within the meaning of section 501(d)(2) of the Federal Food, Drug, and Cosmetic Act (FD&C Act or the Act), 21 U.S.C. 351(d)(2), in that a substance was substituted wholly or in part therefor. In addition, this product is adulterated within the meaning of section 501(a)(2)(B) of the FD&C Act (21 U.S.C. 351(a)(2)(B)), in that the substitution demonstrates that the quality assurance within your facility is not functioning in accordance with Current Good Manufacturing Practice (CGMP) requirements.

In addition, Jaloma Antiseptic Hand Sanitizer is an unapproved new drug introduced or delivered for introduction into interstate commerce in violation of section 505(a) of the FD&C Act, 21 U.S.C. 355(a), and is misbranded under sections 502(j), (a), (e) and (ee) of the FD&C Act, 21 U.S.C. 352(j), (a), (e) and (ee). Introduction or delivery for introduction of such products into interstate commerce is prohibited under sections 301(d) and (a) of the FD&C Act, 21 U.S.C. 331(d) and (a). These violations are described in more detail below.

Adulteration Violations

Jaloma Antiseptic Hand Sanitizer, declared to be as manufactured at your facility, is labeled to contain 62% volume/volume (v/v) of the active ingredient ethyl alcohol (ethanol). However, FDA laboratory testing of a batch of this product detained at the border found that it contained on average 32% ethanol and 32% methanol v/v. Therefore, this hand sanitizer drug product is adulterated under section 501(d)(2) of the FD&C Act in that the active ingredient, ethanol, was substituted wholly or in part with methanol, a dangerous chemical when in contact with human skin or ingested.

Methanol is not an acceptable ingredient for hand sanitizers and should not be used due to its toxic effects. Skin exposure to methanol can cause dermatitis, as well as transdermal absorption with systemic toxicity. Substantial methanol exposure can result in nausea, vomiting, headache, blurred vision, permanent blindness, seizures, coma, permanent damage to the nervous system, or death. Although all persons using these products on their hands are at risk, young children who accidentally ingest these products, and adolescents and adults who drink these products as an alcohol (ethanol) substitute, are most at risk for methanol poisoning.

On July 22, 2020, FDA held a teleconference with you and your registered U.S. agent, Registrar Corp. We recommended you consider removing all of your firm’s hand sanitizer drug products currently in distribution to the U.S. market. On July 24, 2020, FDA notified the public of the methanol contamination of your hand sanitizer drug product at the following website: https://www.fda.gov/drugs/drug-safety-and-availability/fda-updates-hand-sanitizers-consumers-should-not-use#products

On July 31, 2020, you issued a voluntary nationwide recall for all Jaloma Antiseptic Hand Sanitizer drug products within expiry due to potential presence of undeclared methanol (wood alcohol), as noted on the following FDA website: https://www.fda.gov/safety/recalls-market-withdrawals-safety-alerts/laboratorios-jaloma-sa-de-cv-issues-voluntary-recall-jaloma-antiseptic-hand-sanitizer-due-potential

In response to this letter provide:

• A detailed investigation into how the drug product described above, which was declared to be manufactured at your facility and which was labeled as containing ethanol, was substituted in part or in whole with methanol.
• A list of all raw materials used to manufacture all of your hand sanitizer drug products, including the suppliers’ names, addresses, and contact information.
• A list of all batches of any hand sanitizer drug products shipped to the United States by your firm, and a full reconciliation of all material you distributed.
• Copies of the complete batch records for all batches distributed to the U.S.
• Information regarding analytical test results for your hand sanitizer drug products, as you stated you would during the July 22, 2020 teleconference.

The substitution and contamination with methanol in a drug product declared to be manufactured in your facility demonstrates that the quality assurance within your facility is not functioning in accordance with CGMP requirements under section 501(a)(2)(B) of the FD&C Act.1

Unapproved New Drug and Misbranding Violations

Jaloma Antiseptic Hand Sanitizer is a “drug” as defined by section 201(g)(1)(B) of the FD&C Act, 21 U.S.C. 321(g)(1)(B), because it is intended for use in the diagnosis, cure, mitigation, treatment, or prevention of disease, and/or under section 201(g)(1)(C) of the FD&C Act, 21 U.S.C. 321(g)(1)(C), because it is intended to affect the structure or any function of the body.

Specifically, this product is intended for use as a topical antiseptic.

Examples of claims observed on the Jaloma Antiseptic Hand Sanitizer product label and labeling that provide evidence of the intended use (as defined in 21 CFR 201.128) of the product include, but may not be limited to, the following:

  “Antiseptic Hand Sanitizer . . . Drug Facts . . . Use For hand washing to decrease bacteria on the skin”

  “Directions Wet hands thoroughly with product and allow to dry without wiping”2

This topical antiseptic product is a “new drug” within the meaning of section 201(p) of the FD&C Act, 21 U.S.C. 321(p), because it is not generally recognized as safe and effective (GRASE) for use under the conditions prescribed, recommended, or suggested in its labeling. New drugs may not be introduced or delivered for introduction into interstate commerce without prior approval from FDA, as described in section 505(a) of the FD&C Act, 21 U.S.C. 355(a), unless they are lawfully marketed under section 505G of the FD& C Act (which is not the case for this product, as further described below).

No FDA-approved application pursuant to section 505 of the FD&C Act, 21 U.S.C. 355, is in effect for this drug product, nor are we aware of any adequate and well-controlled clinical studies in the published literature that support a determination that your Jaloma Antiseptic Hand Sanitizer drug product is GRASE for use under the conditions suggested, recommended, or prescribed in its labeling. Accordingly, this product is an unapproved new drug marketed in violation of sections 505(a) and 301(d) of the FD&C Act, 21 U.S.C 355(a) and 331(d).

We note that over-the-counter (OTC) topical antiseptic products had been the subject of rulemaking under the Agency’s OTC Drug Review. In particular, such products were addressed in a tentative final monograph (TFM) entitled “Topical Antimicrobial Drug Products for Over-the-Counter Human Use; Tentative Final Monograph for Health-Care Antiseptic Drug Products,” Proposed Rule, 59 FR 31402 (June 17, 1994) (1994 TFM), as further amended by “Safety and Effectiveness of Consumer Antiseptics; Topical Antimicrobial Drug Products for Over-the-Counter Human Use; Proposed Amendment of the Tentative Final Monograph; Reopening of Administrative Record,” Proposed Rule, 81 FR 42912 (June 30, 2016)(Consumer Antiseptic Rubs Proposed Rule).

Over the course of these rulemakings, three active ingredients (benzalkonium chloride, ethyl alcohol (ethanol), and isopropyl alcohol) were classified as Category III for use in consumer antiseptic rub products, meaning that additional safety and effectiveness data are needed to support a determination that a drug product containing one of these active ingredients would be GRASE for use as a consumer antiseptic rub. Additionally, OTC consumer antiseptic washes were addressed in “Safety and Effectiveness of Consumer Antiseptics; Topical Antimicrobial Drug Products for Over-the-Counter Human Use,” Proposed Rule, 78 FR 76444 (December 17, 2013)(Consumer Antiseptic Washes Proposed Rule) and “OTC Safety and Effectiveness of Topical Antimicrobial Drug Products for Over-the-Counter Human Use,” Final Rule, 81 FR 61106 (September 6, 2016). We note that ethyl alcohol is not one of the active ingredients that was classified as Category III for use as an active ingredient in a consumer antiseptic wash. Under the Consumer Antiseptic Washes rulemaking, ethyl alcohol was determined to be ineligible for evaluation under the OTC Drug Review for use as an active ingredient in consumer antiseptic washes.

Section 505G of the FD&C Act addresses nonprescription drugs marketed without an approved application. Under section 505G(a)(3) of the FD&C Act, drugs that were classified as Category III for safety or effectiveness in a TFM that is the most recently applicable proposal or determination for such drug issued under 21 CFR Part 330 – and that were not classified as Category II for safety or effectiveness – are not required to have an approved application under section 505 in order to be marketed, as long as they are in conformity with the relevant conditions of use outlined in the applicable TFM, including the active ingredient, and comply with all other applicable requirements.

However, Jaloma Antiseptic Hand Sanitizer does not conform to the 1994 TFM, as further amended by the 2016 Consumer Antiseptic Rubs Proposed Rule and the 2013 Consumer Antiseptic Washes Proposed Rule, nor any other TFM, proposed rule, or final rule, and does not meet the conditions under section 505G(a)(3) of the FD&C Act for marketing without an approved application under section 505.

According to the product label, Jaloma Antiseptic Hand Sanitizer purportedly contains the active ingredient ethyl alcohol 62%.3 However, as previously discussed, FDA laboratory analyses of a batch of this product detained at the border demonstrated that Jaloma Antiseptic Hand Sanitizer contains ethanol in a concentration that is less than the 62% stated on its product label and less than the amount of ethanol described in the 1994 TFM.4 Such a product does not conform with the TFM or the applicable requirements, nor is it consistent with the formulations described in the guidances setting forth FDA’s temporary policies for hand sanitizers during the COVID-19 public health emergency.5

FDA laboratory analyses also demonstrated that a batch of Jaloma Antiseptic Hand Sanitizer contains significant concentrations of the undeclared ingredient methyl alcohol (methanol). Use of methanol as an active ingredient is not in conformance with the TFM, nor is methanol included in the formulations described in FDA’s Temporary Policy for Preparation of Certain Alcohol-Based Hand Sanitizer Products During the Public Health Emergency (COVID-19) Guidance for Industry. Furthermore, methanol is not acceptable as an inactive ingredient in hand sanitizers. As previously discussed, methanol has significant and sometimes fatal toxic effects and, therefore, does not meet the requirements under 21 CFR 330.1(e) that aproduct’s inactive ingredients be safe and suitable.6

Additionally, this methanol-containing drug product, Jaloma Antiseptic Hand Sanitizer, is misbranded, under sections 502(j), (a), (e), and (ee) of the FD&C Act, 21 U.S.C. 352(j), (a), (e), and (ee). It is misbranded under section 502(j) of the FD&C Act, 21 U.S.C. 352(j), because it is dangerous to health when used according to its labeling as a hand sanitizer. As previously stated, skin exposure to methanol could lead to systemic absorption, and substantial methanol exposure can potentially result in, among other things, blindness, permanent nervous system damage, and even death.

This hand sanitizer is misbranded under section 502(a) of the FD&C Act, 21 U.S.C 352(a), because its labeling is false and misleading. As noted above, Jaloma Antiseptic Hand Sanitizer is labeled to contain ethyl alcohol 62%. However, FDA laboratory analyses demonstrated that a batch of this product contains a concentration of ethyl alcohol (ethanol) that is less than what is stated on the product label and contains a significant concentration of methyl alcohol (methanol), an ingredient that is not declared on the product labels. Section 201(n) of the FD&C Act, 21 U.S.C. 321(n), provides that “in determining whether the labeling or advertising is misleading there shall be taken into account . . . not only representations made or suggested . . . but also the extent to which the labeling or advertising fails to reveal facts material in the light of such representations or material with respect to consequences which may result. . .” Thus, the misleading representation of the concentration of the active ingredient ethyl alcohol (ethanol), and the failure of the product label to disclose the presence of the methyl alcohol (methanol) in the product, causes this product to be misbranded under section 502(a) of the FD&C Act, 21 U.S.C. 352(a). The failure of this product to list methyl alcohol (methanol) as an ingredient on its label also causes it to be misbranded under section 502(e)(1)(A) of the FD&C Act, 21 U.S.C. 352(e)(1)(A).

Lastly, this product is misbranded under section 502(ee) of the FD&C Act, 21 U.S.C. 352(ee), because Jaloma Antiseptic Hand Sanitizer is a nonprescription drug subject to section 505G of the FD&C Act, 21 U.S.C. 355h, but does not comply with the requirements for marketing under that section and is not the subject of an application approved under section 505 of the FD&C Act, 21 U.S.C. 355.

The introduction or delivery for introduction of a misbranded drug into interstate commerce is prohibited under section 301(a) of the FD&C Act, 21 U.S.C. 331(a).

CGMP Consultant Recommended

Based upon the nature of the violations we identified at your firm, we strongly recommend engaging a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements if your firm intends to resume manufacturing drugs for the U.S. market. We also recommend that the qualified consultant perform a comprehensive audit of your entire operation for CGMP compliance and that the consultant evaluates the completion and efficacy of your corrective actions and preventive actions before you pursue resolution of your firm’s compliance status with FDA. Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.

Conclusion

The violations cited in this letter are not intended to be an all-inclusive list of violations associated with your drug products. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.

Note that FDA placed all drugs and drug products manufactured by your firm on Import Alert 66-78 on August 3, 2020, as the methods used in and controls used for the manufacture, processing, packing, or holding of these products do not appear to conform to current good manufacturing practices within the meaning of section 501(a)(2)(B) of the FD&C Act. Drugs and drug products that appear to be adulterated or misbranded may be detained or refused admission without physical examination.

All drugs and drug products manufactured by your firm may remain listed on this import alert, until there is evidence establishing that the conditions that gave rise to the appearance of a violation have been resolved, and the Agency has confidence that future entries will be in compliance with the FD&C Act. This may include an inspection prior to the Agency considering the appearance of adulteration to be addressed.

If you decide you want to manufacture drugs for the United States in the future, request a Regulatory Meeting to discuss corrective actions.

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 15 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov

Please identify your response with FEI 3002600322 and ATTN: Carla Norris

Sincerely,
/S/

Francis Godwin
Director
Office of Manufacturing Quality
Office of Compliance
Center for Drug Evaluation and Research

CC:
David Lennarz
Registered US Agent:
Registrar Corp
144 Research Drive
Hampton VA, 23666

_________________________________________

1 Due to an increased demand for alcohol-based hand sanitizers during the COVID-19 pandemic, FDA published the Guidance for Industry: Temporary Policy for Preparation of Certain Alcohol-Based Hand Sanitizer Products During the Public Health Emergency (COVID-19) on March 19, 2020, and subsequently updated the guidance several times, most recently on August 7, 2020. This guidance communicates the Agency’s temporary policy that we do not intend to take action against firms for CGMP violations under section 501(a)(2)(B) of the FD&C Act if such firms prepare alcohol-based hand sanitizers for consumer use (or for use as a health care personnel hand rub) during the public health emergency, provided certain circumstances described in the guidance are present. These circumstances include preparation of hand sanitizer products using only the ingredients and formulas set forth in the guidance. In addition to the violative sample results detailed above that demonstrate the substitution of hand sanitizer products declared to be manufactured at your facility, a review of the formulations on the drug products’ labeling further indicates that these products are not prepared consistent with FDA’s temporary policy set forth in the guidance. Therefore, these products do not fall within the Agency’s temporary policy not to take action against firms manufacturing hand sanitizer products for violations of section 501(a)(2)(B) of the FD&C Act.

2 We note that your Jaloma Antiseptic Hand Sanitizer labeling contains conflicting information regarding whether it should be used as a consumer antiseptic wash or a consumer antiseptic rub. The term “hand sanitizer” generally refers to consumer antiseptic rubs, and the Drug Facts Label of your product both indicates that the product is to be used for hand washing (presumably with water) and suggests that it should be used without water (i.e., “Wet hands thoroughly with product and allow to dry without wiping”). The Jaloma Antiseptic Hand Sanitizer product, however, does not conform to the requirements for either a consumer antiseptic rub or a consumer antiseptic wash, as further described below.

3 As previously noted, statements on the Jaloma Antiseptic Hand Sanitizer label suggest both that the product is a consumer antiseptic wash and that it is a consumer antiseptic rub. However, ethanol (in any concentration) is not an active ingredient permitted for use in consumer antiseptic hand washes under the 1994 TFM as amended by the 2013 Consumer Antiseptic Washes Proposed Rule. Moreover, antiseptic washes are outside the scope of FDA’s temporary policies for hand sanitizers.

4 The 1994 TFM, which does not distinguish between antiseptic hand washes and rubs, proposed for antiseptic handwashes and healthcare personnel handwashes an alcohol concentration of 60 to 95% by volume in an aqueous solution. 59 FR at 31442. Later amendments to the 1994 TFM distinguished between antiseptic hand washes and rubs, and between consumer and healthcare personnel antiseptics, but did not change the alcohol concentration originally proposed in 1994.

5 See, e.g., Temporary Policy for Preparation of Certain Alcohol-Based Hand Sanitizer Products During the Public Health Emergency (COVID-19). Because Jaloma Antiseptic Hand Sanitizer is not consistent with the formulations described in these guidances, it does not fall within any temporary Agency policy not to take action against firms manufacturing hand sanitizer products for violations of section 505 of the FD&C Act.

6 An inactive ingredient used in OTC monograph drugs must meet the requirements of 21 CFR 330.1(e), which requires, among other things, that inactive ingredients must be safe in the amount administered.

無料会員 1,000名 突破

米国 FDA 警告書の全文閲覧は会員限定です

無料で会員登録する

出典: fda.gov(U.S. FDA)の Warning Letters 公開情報 (米国政府著作物としてパブリックドメイン)をそのまま掲載しています。内容の正確性・最新性は保証されません。FDA が本サイトの内容を承認・保証するものではありません。

Warning Letter の最新状態・Close-out(是正完了)の正は FDA 公式サイトです。是正が完了した企業には Close-out Letter が発行される場合があり、本サイトの表示が最新の状態を反映していないことがあります。掲載は事実の転載であり、企業の現在の法令遵守状況について評価・断定するものではありません。

取得日: 2026.11.17

各データセット(510(k)・PMA・MAUDE・回収・Warning Letter)の解説は 米国FDA情報の概要 を参照してください。