Posterior Cervical Screw System(NKG)

頸椎後方固定用スクリューシステム この日本語名は AI が生成した参考訳です。正式名称は英語の原名です。

米国回収

6

直近 2021.02.03

510(k)

118

PMA

0

不具合報告

2,196

分類情報

Product Code NKG
デバイス名 Posterior Cervical Screw System

頸椎後方固定用スクリューシステム この日本語名は AI が生成した参考訳です。正式名称は英語の原名です。

デバイスクラス クラス II
21 CFR 規制番号 888.3075
審査区分 510(k)(市販前届出)
医療専門分野 整形外科
定義 Posterior cervical screw systems are intended for use in fusion procedures of the cervical spine and/or craniocervical junction and/or cervicothoracic junction for: 1) spinal fractures and dislocations; 2) deformities; 3) instabilities; 4) failed previous fusions; 5) tumors; 6) inflammatory disorders; 7) spinal degeneration, 8) facet degeneration with instability; and 9) reconstruction following decompression to treat radiculopathy and/or myelopathy. These systems are also intended to stabilize the spine in the absence of fusion for a limited time period in patients with tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

後方頸椎スクリューシステムは、頸椎及び/又は頭蓋頸椎接合部及び/又は頸胸椎接合部の固定術において、1)脊椎骨折及び脱臼、2)変形、3)不安定性、4)過去の固定術の失敗、5)腫瘍、6)炎症性疾患、7)脊椎変性、8)不安定性を伴う椎間関節変性、及び9)神経根症及び/又は脊髄症を治療するための除圧術後の再建、に使用することを目的とする。また、これらのシステムは、固定術を行うのに十分な生存期間が見込まれない頸椎腫瘍患者において、固定を行わない状態で限られた期間、脊椎を安定化させることも目的とする。 この日本語訳は AI が生成した参考訳です。正確な内容は英語の原文をご確認ください。

フラグ
インプラント機器
AI分析

本品は米国においてクラスIIに分類される医療機器であり、市販前届出(510(k))による審査区分に位置づけられています。クラスIIは中等度のリスクを有する機器に適用される区分であり、既に合法的に販売されている同等の機器との実質的同等性を示すことにより市販前届出が認められ、PMAのような臨床データを伴う厳格な審査は通常求められません。

米国市場での動向

本製品は510(k)(市販前届出)区分の医療機器で、これまでに約120件の届出があり、参入企業数は62社、直近5年間では約30件の届出が確認されています。不具合報告(MDR)は累計で約2,200件寄せられており、死亡15件、傷害約1,400件、不具合(Malfunction)約750件と傷害の比率が高い内訳で、主な問題としてはFracture(破損)、Migration(移動)、Break(破断)が挙げられています。回収は累計6件で、いずれもクラスII(中程度)に分類され、クラスI(最重篤)の回収は確認されていません。最新の回収は2020年12月に開始されており、主な根本原因としてはNonconforming Material/Component(規格外の材料・部品)、Process control(工程管理)、Employee error(作業者エラー)が挙げられています。

この分析は公開データ(openFDA・JMDN 対応情報)をもとに AI が生成した参考情報です。市場データは2026年8月時点の集計に基づきます。

関連 product code

同じ 21 CFR 888.3075 に分類される product code(1 件)

No.product code機器名クラス専門分野510(k)PMA不具合回収
1QSD

Posterior Cervical Screw Placement Guide

後方頸椎スクリュー設置ガイド

II整形外科2

機器名の日本語訳は AI により自動生成したものです。正確には英語原文をご確認ください。

類似の国内医療機器(自動推定)

FDA デバイス分類と JMDN 英語名の名称・定義文の類似度から機械的に推定した候補です。日米の当局が定めた公的な対応関係ではなく、参考情報としてご覧ください。

No.類別一般的名称品目数企業数年間総出荷額成長率平均価格国産比率
1整形用品脊椎内固定器具クラスⅢ36347662 億円/年+25.7% 3.67 万円/個9.7%
2整形用機械器具整形外科用脊椎外固定システムクラスⅢ

FDA のデバイスクラスは 3 段階(クラス I〜III)、日本の医療機器は 4 段階(クラス I〜IV)で分類されており、 1 対 1 では対応しません。 リスク区分の考え方が異なるため、参考情報としてご利用ください。

米国での回収・承認・不具合報告

無料会員 1,000名 突破

回収・承認・不具合報告の明細の閲覧は会員限定です

無料で会員登録する
この企業の Warning Letter を検索: K2M, IncSynthes (USA) Products LLCOrthofix, Inc
回収番号クラス回収開始日企業理由ステータス
Z-0931-2021 NKGクラス II2020.12.14K2M, Inc

The Yukon polyaxial screw used in the Yukon Spinal System was incorrectly laser marked with size 5.0 mm (diameter) & 24 mm (length).

終了
Z-0520-2021 NKGクラス II2020.11.03K2M, Inc

Shafts do not pass through the inner cannula of the Anti-Torque Alignment Tube from Lot KTGG due to a manufacturing nonconformance. This could result in a delay of surgery or result in surgical intervention later on.

終了
Z-0223-2020 NKGクラス II2019.09.16Synthes (USA) Products LLC

The subject product measures 4.0mm in diameter instead of 3.5mm.

終了
Z-0110-2020 NKGクラス II2018.07.24K2M, Inc

Screws had a manufacturing error that could prevent the screw from mating with the screw inserter or set screw as intended. This event was reported to FDA as part of Stryker's retrospective review of K2M product field actions; the action was completed in 2018.

終了
Z-1364-2018 NKGクラス II2018.02.23Orthofix, Inc

Orthofix is conducting a voluntary recall of the Connector System Large Set Screw (PN: 79-2002) with affected Lot Numbers 001 and 002, and Small Set Screw (PN: 79-2003) with affected Lot Numbers 002, 003 and 004. Through the company's manufacturing controls, size discrepancies were noted with the drive feature for both the large and small sets screws. As a result, it is possible that (1) the set screw drive feature will not accept the Set Screw Driver (PN: 79-1006) or (2) the driver may get wedged in the corners of the drive feature (false bottom) which may lead to a stripped set screw.

終了
Z-1363-2018 NKGクラス II2018.02.23Orthofix, Inc

Orthofix is conducting a voluntary recall of the Connector System Large Set Screw (PN: 79-2002) with affected Lot Numbers 001 and 002, and Small Set Screw (PN: 79-2003) with affected Lot Numbers 002, 003 and 004. Through the company's manufacturing controls, size discrepancies were noted with the drive feature for both the large and small sets screws. As a result, it is possible that (1) the set screw drive feature will not accept the Set Screw Driver (PN: 79-1006) or (2) the driver may get wedged in the corners of the drive feature (false bottom) which may lead to a stripped set screw.

終了

510(k)(市販前届出)

全 118 件
No.番号機器名申請者決定日種別概要
1K253195 TAURUS Posterior Occipital-Cervico-Thoracic Spinal SystemsZheJiang Decans Medical Devices Co., Ltd.2026.06.02通常(Traditional) PDF
2K254045 CarboClear® Posterior Cervical Screw System; CarboClear® Hybrid Posterior Cervical Screw SystemCarboFix Orthopedics , Ltd.2026.03.16通常(Traditional) PDF
3K254165 Infinity™ OCT SystemMedtronic Sofamor Danek USA, Inc.2026.01.21特別(Special) PDF
4K252327 CMORE® CT System; CMORE® CT System Navigated InstrumentsIcotec AG2025.11.12通常(Traditional) PDF
5K253129 Infinity™ OCT SystemMedtronic Sofamor Danek USA, Inc.2025.10.24特別(Special) PDF
6K251725 ANAX™ OCT Spinal SystemCg Medtech Co., Ltd.2025.06.25特別(Special) PDF
7K250866 Sovereign Posterior Cervical SystemMet One Technologies, LLC2025.05.20通常(Traditional) PDF
8K242674 Freedom Posterior Cervical ScrewsSignature Orthopaedics Pty, Ltd.2025.05.13通常(Traditional) PDF
9K250332 Virage® OCT Spinal Fixation SystemHighridge Medical, LLC2025.04.04通常(Traditional) PDF
10K242516 EUROPA™ Posterior Cervical Fusion SystemMiRus, LLC2024.11.19通常(Traditional) PDF
11K233989 CarboClear® Posterior Cervical Screw SystemCarboFix Orthopedics , Ltd.2024.03.27通常(Traditional) PDF
12K231850 QUARTEX® Occipito-Cervico-Thoracic Spinal System ExcelsiusGPS® InstrumentsGlobus Medical, Inc.2024.03.14通常(Traditional) PDF
13K233332 Statera-C™ Spinal SystemK&J Consulting Corp.2023.11.27通常(Traditional) PDF
14K233078 Posterior Cervical Spine SystemDouble Medical Technology, Inc.2023.11.22通常(Traditional) PDF
15K233366 SYMPHONY OCT SystemMedos International SARL2023.11.09特別(Special) PDF
16K232167 VySpan™ PCT SystemVy Spine, LLC2023.09.27特別(Special) PDF
17K231654 NorthStar OCT SystemSeaspine, Inc.2023.08.03通常(Traditional) PDF
18K231840 CastleLoc-S Posterior Cervical Fixation SystemL&K BIOMED Co., Ltd.2023.07.20特別(Special) PDF
19K221307 Edge Upper Cervical SystemSpinal Simplicity, LLC2023.07.10通常(Traditional) PDF
20K230614 Cortium™Ulrich Medical USA2023.05.02通常(Traditional) PDF

出典の openFDA は各 510(k) の主要(primary)product code のみを収録しているため、副次コードを含む FDA 公式データベースの検索結果とは件数が異なる場合があります。 FDA 510(k) データベースで確認

PMA(市販前承認)

この product code の PMA 情報はありません。

不具合報告(MAUDE)トレンド

米国不具合報告検索で詳しく見る

出典: openFDA(U.S. FDA) のデータをそのまま掲載しています。内容の正確性・最新性は保証されません。FDA が本サイトの内容を承認・保証するものではありません。

報告の存在は、機器と事象の因果関係を意味しません。報告件数を機器間の不具合発生率の比較に用いることはできません。

各データセット(510(k)・PMA・MAUDE・回収・Warning Letter)の解説は 米国FDA情報の概要 を参照してください。

不具合報告データを読み込み中...

出典: openFDA(U.S. FDA) のデータをそのまま掲載しています。内容の正確性・最新性は保証されません。FDA が本サイトの内容を承認・保証するものではありません。

取得日: 2026.09.07