Real Time Nucleic Acid Amplification System(OOI)

リアルタイム核酸増幅システム この日本語名は AI が生成した参考訳です。正式名称は英語の原名です。

米国回収

30 件

直近 2025.04.30

510(k)

14 件

PMA

0 件

不具合報告

2,778 件

分類情報

Product Code OOI
デバイス名 Real Time Nucleic Acid Amplification System

リアルタイム核酸増幅システム この日本語名は AI が生成した参考訳です。正式名称は英語の原名です。

デバイスクラス クラス II
21 CFR 規制番号 862.2570
審査区分 届出免除(510(k) Exempt)
医療専門分野 臨床化学
定義 The system is a clinical multiplex instrument intended to measure and sort multiple signals generated my multiple probes, intercalating dyes, or other ligands in an assay from a clinical sample. Signals may be generated by fluorescence or other phenomena and may be measured using filters on a photodiode or other detector. It may integrate sample and/or reagent handling, amplification, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. The system is used with specific assays to comprise an assay test system.

本システムは、臨床検体を用いたアッセイにおいて、複数のプローブ、インターカレート色素、またはその他のリガンドにより生じる複数の信号を測定し分類することを目的とした、臨床用マルチプレックス機器である。信号は蛍光またはその他の現象により生成され、フォトダイオードその他の検出器上のフィルターを用いて測定され得る。本システムは、信号読取ユニットとともに、検体および/または試薬の取り扱い、増幅、専用の機器制御、データ収集用ソフトウェア、生データ保存機構、その他の必須ハードウェア構成要素を統合していてもよい。本システムは特定のアッセイと共に用いられ、アッセイ試験システムを構成する。 この日本語訳は AI が生成した参考訳です。正確な内容は英語の原文をご確認ください。

フラグ
該当なし
AI分析

本機器は米国においてクラスIIに区分されており、通常は市販前届出(510(k))の対象となる規制区分に属しますが、本製品コードについてはその届出義務が免除されています。これは、一般的な管理(general controls)に加え、必要に応じた特別管理(special controls)により安全性および有効性を確保できると判断された機器に適用される取り扱いであり、市販前届出の手続きを経ずに市場に出すことが認められています。

米国市場での動向

510(k)届出は累積約14件で、直近5年では約3件、参入企業は10社となっています。不具合報告は累積約2,700件で、大半が不具合(Malfunction)であり、死亡報告はなく傷害は23件です。主な問題としてはFalse Positive Result(偽陽性)、Program or Algorithm Execution Problem(プログラムまたはアルゴリズム実行の問題)、Fluid/Blood Leak(体液・血液の漏れ)が挙げられています。回収は累積約30件で、クラスIIが約25件、クラスIIIが2件、クラスIは確認されていません。直近5年では約16件の回収があり、最新の回収は2025年3月に開始されています。

この分析は公開データ(openFDA・JMDN 対応情報)をもとに AI が生成した参考情報です。市場データは2026年8月時点の集計に基づきます。

関連 product code

同じ 21 CFR 862.2570 に分類される product code(7 件)

No.product code機器名クラス専門分野510(k)PMA不具合回収
1NSU

Instrumentation For Clinical Multiplex Test Systems

臨床マルチプレックス検査システム用機器

II臨床化学13—15212 件
2OVA

Complete Gene Expression Profiling Accessory Reagents

遺伝子発現プロファイリング用付属試薬

II臨床化学1———
3PCA

Dna Genetic Analyzer

DNA遺伝子解析装置

II臨床化学1—6—
4OTA

Mass Spectrometer For Clinical Multiplex Test Systems

臨床用マルチプレックス検査システム用質量分析装置

II臨床化学———1 件
5OUE

Micro Total Analysis Instrument System

マイクロ総合分析装置システム

II臨床化学———2 件
6PHG

Droplet Digital Pcr System

II臨床化学————
7PQQ

Data Acquisition Software

データ収集ソフトウェア

II臨床化学———1 件

機器名の日本語訳は AI により自動生成したものです。正確には英語原文をご確認ください。

類似の国内医療機器(自動推定)

FDA デバイス分類と JMDN 英語名の名称・定義文の類似度から機械的に推定した候補です。日米の当局が定めた公的な対応関係ではなく、参考情報としてご覧ください。

No.類別一般的名称品目数企業数年間総出荷額成長率平均価格国産比率
1理学診療用器具超音波増幅器クラスⅡ——————
2血液検査用器具遺伝子解析装置クラスⅠ783652.68 億円/年-29.6% 175.97 万円/個19.4%

FDA のデバイスクラスは 3 段階(クラス I〜III)、日本の医療機器は 4 段階(クラス I〜IV)で分類されており、 1 対 1 では対応しません。 リスク区分の考え方が異なるため、参考情報としてご利用ください。

米国での回収・承認・不具合報告

無料会員 1,000名 突破

回収・承認・不具合報告の明細の閲覧は会員限定です

無料で会員登録する
この企業の Warning Letter を検索: Abbott Molecular, Inc.Biocartis NvHologic, Inc.
回収番号クラス回収開始日企業理由ステータス
Z-1665-2025 OOIクラス II2025.03.20Abbott Molecular, Inc.

The design of the Alinity m System Solutions drawer enclosure may allow liquid (liquid waste or system solutions) originating in the System Solutions drawer to flow beyond the footprint of the instrument and into the walking-path of the user.

対応中
Z-0836-2025 OOIクラス II2024.12.10Biocartis Nv

False-positive MSI-H results generated by the Idylla MSI Test.

対応中
Z-1602-2024 OOIクラス II2024.03.20Abbott Molecular, Inc.

The Alinity m System camera detects whether tubes are "capped." If the camera detects a cap and the retention bar is not present on the sample rack, the system will generate the message 'Error - 6013: Has cap, no retention bar." Abbott has identified an issue concerning the use of certain third-party Universal Transport Medium (UTM) tubes on the Alinity m System. This issue has been observed with Copan UTM-RT 3 mL Without Beads Transport & Preservation Medium for Viral Molecular Diagnostics Testing, Part Number (PN) 3C047N. However, it is possible that other third party manufactured tubes could experience the same issue.

対応中
Z-1190-2024 OOIクラス III(軽微)2024.02.01Abbott Molecular, Inc.

Products that were intended for export only which were not approved or registered in accordance with U.S. specifications were shipped to U.S. customers.

対応中
Z-0782-2024 OOIクラス II2023.12.15Hologic, Inc.

Due to potential false positive Flu B results when a sample was also SARS-CoV-2 positive.

対応中
Z-2153-2023 OOIクラス II2023.06.14DiaSorin Molecular LLC

There is a potential for the direct amplification disc to malfunction which may result in spillage of liquid from the disc.

対応中
Z-1009-2023 OOIクラス II2022.12.09Abbott Molecular, Inc.

The firm identified the following three potential issues which may have impacted ADUs installed on distributed Alinity m Systems. 1. Systems which had their ADUs serviced may have an incorrect board value (calibration data file) referenced causing a misconfiguration of the calibration. 2. Inability of Maintenance and Diagnostics 2300 (Amp Detect Optical Calibrations) to recognize error handling and thermal hold errors during the calibration process, potentially leading to a misconfiguration of the calibration. 3. Under specific conditions during the ADU manufacturing process, an incorrect calibration may potentially have been configured.

対応中
Z-1349-2023 OOIクラス II2022.11.11Abbott Molecular, Inc.

The instrument was found to be installed without plunger assemblies in the clamp bar for an Amplification Detection Unit. After correction of the issue, the instrument was returned for use without calibration. This would result in a potential for delay of results and incorrect results.

対応中
Z-0268-2023 OOIクラス II2022.10.12Abbott Molecular, Inc.

Abbott has identified potential performance issues for the Alinity m System software version 1.6.5: 1) In a unique scenario, the waste chute flapper was found to not open when the Systems Solution drawer was closed and locked. It was found that the software will cause the flapper door to stay in the closed position when the drawer is closed and locked if the flapper had previously been moved out of position. 2) Sample preparation drawer #1 barcode information is used instead of sample prep drawer #2 when the scanned data is not sent to the System Control Center before the next bottle barcode in sample prep drawer#2 is scanned. 3) Under a specific condition, while the system is processing tests and a new test request is made, when the level of the bulk solution is too low to process a test, the software would error stop the system and try to complete all in-process tests. An internal counter is reset which can cause reaction vessels (RVs) already present in an Amplification Detection Unit (or amp detect) to remain there and not be moved to waste so that more RVs can be placed into the amp detect for processing. 4) 4 to 6 replicates of the same auto calibrator orders can be run with 2 different sets of calibrator materials on the same rack. It was discovered during internal testing, when running 4 to 6 replicates of a calibrator, it is possible for the user to use 2 separate lots of material which is not detected by the System Control Center (SCC). If this were to occur, the calibration curve would be created using 2 separate material lots. In normal use scenario, this curve would be made using only 1 lot of material.

対応中
Z-1479-2022 OOIクラス II2022.06.22Meridian Bioscience Inc

When a run is aborted, the cooling period protection does not occur and the user is able to open the lid prior to the completion of the cooling period, exposing the user to heated instrument components. Incidental contact with heated instrument components may result in an injury such as minor burns.

対応中
Z-1092-2022 OOIクラス II2022.04.05Luminex Corporation

Heater within the Verigene System may be outside of established temperature limits for assays which could result in false negative results.

対応中
Z-0836-2022 OOIクラス II2022.02.15Meridian Bioscience Inc

The photomultiplier tube, may have compromised functionality in some instruments. As a result, the user is likely to observe an increase in false-positive or indeterminate results.

対応中
Z-0710-2022 OOIクラス II2022.02.11Abbott Molecular, Inc.

There is potential for the Reaction Vessels (RVs) detaching from the RV cap during transport by the pipettor robot.

終了
Z-0457-2022 OOIクラス II2021.11.19DiaSorin Molecular LLC

A subset of affected discs are at risk of leakage when it is used more than one time with Simplexa COVID-19 Direct and/or Simplexa Flu A/B & RSV Direct Gen II. Leakage from a well that had a positive sample may cause further cross-contamination in areas of the lab if not properly cleaned.

対応中
Z-0553-2022 OOIクラス II2021.11.17Luminex Corporation

Impacted lot may leak inside the ARIES instrument. Testing confirmed a leak rate of 0.9%. Leaking cassettes could potentially lead to incorrect results or a delay in reporting results due to an Invalid.

終了
Z-0828-2022 OOIクラス II2021.11.16Roche Molecular Systems, Inc.

Roche has identified a small number of cobas Liat analyzer units that have consistently high noise levels (background signal) originating from the amber detector (used for Influenza B detection). This noise increases the probability of false positive Influenza B results.

対応中
Z-0498-2022 OOIクラス II2021.04.16Luminex Corporation

Impacted lot may leak inside the ARIES instrument.

終了
Z-1476-2020 OOIクラス II2020.01.28Qiagen Sciences LLC

When using the Rotor-Gene Q with Software version 2.3.4 completing a LIMs export, the .csv file reports the calculated concentration result value as a logarithmic value, and could lead to a false negative result, which could lead to serious medical consequences such as the suspension or non-initiation of treatment

終了
Z-2288-2019 OOIクラス II2019.02.20Luminex Corporation

Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back side seal (BSS) did not meet design specification, resulting in partially sealed SCAs. The impact of a partial seal of the BSS could result in potential decrease of volume for each solution in the SCAs and decreased sensitivity or stability of the assay.

対応中
Z-2292-2019 OOIクラス II2018.06.29Luminex Corporation

An incorrect control board and firmware installed in some of the Hand Held Barcode Scanners could result in sample/patient mismatch or duplicate results (from other patients specimens) for a patient order.

終了

510(k)(市販前届出)

全 14 件
No.番号機器名申請者決定日種別概要
1K243922 RevogeneMeridian Bioscience, Inc.2025.03.20通常(Traditional) PDF
2K222779 RevogeneMeridian Bioscience, Inc.2023.01.26特別(Special) PDF
3K220480 RevogeneMeridian Bioscience, Inc.2022.07.11通常(Traditional) PDF
4K170558 revogeneGenepoc, Inc.2017.05.25通常(Traditional) PDF
5K161495 ARIES MI System, ARIES HSV 1&2 Assay Cassettes-Carton of 24 (IVD), ARIES HSV 1&2 Assay Protocol File Kit (IVD)Luminex Corporation2016.06.30特別(Special)-
6K160517 ARIES SystemLuminex Corporation2016.04.12特別(Special)-
7K151917 ARIES SystemLuminex Corporation2015.10.06通常(Traditional)-
8K151690 Alere i Instrument, Alere i Influenza A & B, Alere i Strep AAlere Scarborough, Inc.2015.07.16特別(Special) PDF
9K140447 BD VIPER LT SYSTEMBecton, Dickinson and Company2014.05.20通常(Traditional) PDF
10K123955 QUANTSTUDIO DX REAL-TIME PCR INSTRUMENTLife Technologies Corporation2013.03.08通常(Traditional) PDF
11K113319 ROTOR-GENE Q MDXQIAGEN GmbH2012.02.06通常(Traditional) PDF
12K102314 3M INTEGRATED CYCLER (110V) & (220V)Focus Diagnostics, Inc.2010.10.29通常(Traditional) PDF
13K093383 NUCLISENS EASYQ ENTEROVIRUS V1.1., NUCLISENS EASYQ DIRECTOR 2.6, NUCLISENS EASYQ ANALYZER, NUCLISENS MINIMAGbioMerieux, Inc.2010.07.06通常(Traditional) PDF
14K092705 ABBOTT M2000SP AND ABBOTT M2000RT, MODELS 9K14-01 (G-SERIES), 9K14-02 (E-SERIES), 9K1501Abbott Molecular, Inc.2010.05.28通常(Traditional) PDF

出典の openFDA は各 510(k) の主要(primary)product code のみを収録しているため、副次コードを含む FDA 公式データベースの検索結果とは件数が異なる場合があります。 FDA 510(k) データベースで確認

PMA(市販前承認)

この product code の PMA 情報はありません。

不具合報告(MAUDE)トレンド

米国不具合報告検索で詳しく見る

出典: openFDA(U.S. FDA) のデータをそのまま掲載しています。内容の正確性・最新性は保証されません。FDA が本サイトの内容を承認・保証するものではありません。

報告の存在は、機器と事象の因果関係を意味しません。報告件数を機器間の不具合発生率の比較に用いることはできません。

各データセット(510(k)・PMA・MAUDE・回収・Warning Letter)の解説は 米国FDA情報の概要 を参照してください。