Instrumentation For Clinical Multiplex Test Systems(NSU)

臨床マルチプレックス検査システム用機器 この日本語名は AI が生成した参考訳です。正式名称は英語の原名です。

米国回収

12

直近 2024.09.18

510(k)

13

PMA

0

不具合報告

140

分類情報

Product Code NSU
デバイス名 Instrumentation For Clinical Multiplex Test Systems

臨床マルチプレックス検査システム用機器 この日本語名は AI が生成した参考訳です。正式名称は英語の原名です。

デバイスクラス クラス II
21 CFR 規制番号 862.2570
審査区分 届出免除(510(k) Exempt)
医療専門分野 臨床化学
定義 Instrumentation for clinical multiplex test systems is a device that is intended to measure and sort multiple signals generated by an assay from a clinical sample. The generated signals from multiple probes or other ligands may be measured by fluorescence, luminescence, or other physical or chemical properties. The device may integrate scanning, reagent handling, hybridization, washing, dedicated instrument control, data acquisition software, raw data storage mechanisms and other essential hardware components along with the signal reader unit. This instrumentation is used with specific assays to comprise an assay test system to measure multiple analytes of a similar chemical nature for de

臨床マルチプレックス検査システム用機器とは、臨床検体からのアッセイによって生成される複数の信号を測定し、分類することを目的とした機器である。複数のプローブその他のリガンドから生成される信号は、蛍光、発光、その他の物理的又は化学的特性によって測定され得る。本機器は、信号読取ユニットとともに、走査、試薬取扱い、ハイブリダイゼーション、洗浄、専用機器制御、データ取得ソフトウェア、生データ保存機構その他の必須ハードウェア構成部品を統合することがある。本機器は特定のアッセイと共に使用され、類似の化学的性質を有する複数の分析物を測定するためのアッセイ検査システムを構成する。 この日本語訳は AI が生成した参考訳です。正確な内容は英語の原文をご確認ください。

フラグ
該当なし
AI分析

本機器は米国においてクラスIIに分類されていますが、21 CFR 862.2570に基づき市販前届出(510(k))が免除される機器とされています。これは、クラスIIに分類される機器の中でも、リスクが比較的低く、性能規格や特別な管理により安全性・有効性が確保できると判断されたものに適用される規制上の取扱いです。専門分野としては臨床化学(Clinical Chemistry)に位置づけられています。

米国市場での動向

本product codeでは、510(k)届出が累計約10件、参入企業は10社となっており、直近5年間の新規届出は確認されていません。PMAの承認実績はありません。不具合報告は累計約140件で、大半がMalfunction(不具合)であり、死亡報告はなく傷害が6件含まれ、主な問題としてFalse Negative Result(偽陰性結果)、Output Problem(出力の問題)、False Positive Result(偽陽性結果)が挙げられています。回収は累計13件で、クラスI(最重篤)は確認されておらず、大半がクラスII(12件)であり、直近5年間では4件、最新の回収は2025年6月に開始されています。

この分析は公開データ(openFDA・JMDN 対応情報)をもとに AI が生成した参考情報です。市場データは2026年8月時点の集計に基づきます。

関連 product code

同じ 21 CFR 862.2570 に分類される product code(7 件)

No.product code機器名クラス専門分野510(k)PMA不具合回収
1OOI

Real Time Nucleic Acid Amplification System

リアルタイム核酸増幅システム

II臨床化学142,75230 件
2OVA

Complete Gene Expression Profiling Accessory Reagents

遺伝子発現プロファイリング用付属試薬

II臨床化学1
3PCA

Dna Genetic Analyzer

DNA遺伝子解析装置

II臨床化学16
4OTA

Mass Spectrometer For Clinical Multiplex Test Systems

臨床用マルチプレックス検査システム用質量分析装置

II臨床化学1 件
5OUE

Micro Total Analysis Instrument System

マイクロ総合分析装置システム

II臨床化学2 件
6PHG

Droplet Digital Pcr System

II臨床化学
7PQQ

Data Acquisition Software

データ収集ソフトウェア

II臨床化学1 件

機器名の日本語訳は AI により自動生成したものです。正確には英語原文をご確認ください。

類似の国内医療機器(自動推定)

FDA デバイス分類と JMDN 英語名の名称・定義文の類似度から機械的に推定した候補です。日米の当局が定めた公的な対応関係ではなく、参考情報としてご覧ください。

No.類別一般的名称品目数企業数年間総出荷額成長率平均価格国産比率
1血液検査用器具免疫蛍光分析装置クラスⅠ16859.3 億円/年+28.8% 1,244.67 万円/個99.1%
2血液検査用器具移動式免疫蛍光分析装置クラスⅠ24156.28 億円/年-34.0% 116.66 万円/個44.4%
3血液検査用器具乾式臨床化学分析装置クラスⅠ381026.81 億円/年-21.4% 30.63 万円/個94.9%
4血液検査用器具移動式免疫発光測定装置クラスⅠ6614.15 億円/年-14.4% 143.01 万円/個100.0%

FDA のデバイスクラスは 3 段階(クラス I〜III)、日本の医療機器は 4 段階(クラス I〜IV)で分類されており、 1 対 1 では対応しません。 リスク区分の考え方が異なるため、参考情報としてご利用ください。

米国での回収・承認・不具合報告

無料会員 1,000名 突破

回収・承認・不具合報告の明細の閲覧は会員限定です

無料で会員登録する
回収番号クラス回収開始日企業理由ステータス
Z-3122-2024 NSUクラス II2024.08.07BioFire Diagnostics, LLC

Some automated in vitro diagnostic modules and instruments manufactured or serviced between May 2022 and May 2024 were calibrated with internal equipment that may lead modules and instruments to report higher melting temperatures, which may lead to erroneous results including false positive Salmonella, Giardia lamblia, false positive/negative Norovirus, and false negative MRSA.

対応中
Z-0353-2024 NSUクラス II2023.10.17BioFire Diagnostics, LLC

Due to an increased risk of degradation of the power entry switch resulting from arcing inside of the power switch that may result in carbon build-up on the switch contacts. The carbon build-up may lead to excess heating inside of the power switch, subsequently leading to deformation of the power switch case. The deformation can create an opportunity for a power switch electrical short. In addition to an electrical short, deformation may result in an open circuit causing the power switch to fail. This event would only occur after the product is in use.

対応中
Z-0097-2023 NSUクラス II2022.09.08Roche Molecular Systems, Inc.

Reported false positive and invalid results on the affected devices due to anomalous baselines. This may lead to erroneous or delayed diagnoses.

終了
Z-1369-2021 NSUクラス II2021.02.26Hologic, Inc

There is a potential for tube trays to leak which could potentially result in false positive results, false negative results or invalid patient results.

対応中
Z-2990-2020 NSUクラス II2020.08.04Hologic, Inc

Tube trays may leak which could invalidate patient results or assay worklists, causing delayed results for any assays with which they are used. A possibility exists of false negative result with flu A/B/RSV assay or paraflu assay.

終了
Z-0920-2022 NSUクラス II2019.04.22Luminex Corporation

Two of three complaints were initiated due to the customers repeatedly obtaining No Call results on the Processor SPs in question.

対応中
Z-0595-2018 NSUクラス II2018.01.20Hologic, Inc

The Panther or the Panther Fusion glass panel separates from the 19 inch touch screen monitor and could potentially fall and hit an operator.

終了
Z-0027-2018 NSUクラス II2017.09.15Hologic, Inc

An incorrect incubator was installed on one Panther System which potentially led to incorrect Aptima Combo 2(R) assay (AC2) results.

終了
Z-0394-2018 NSUクラス II2017.07.18Becton Dickinson & Co.

BD recently notified customers in July 2017 regarding an increased rate of unresolved (UNR) and indeterminate (IND) results for the BD MAXTM Vaginal Panel, experienced by some customers. A non-reportable result may lead to repeat of the test and/or re-collection of a specimen.

終了
Z-0393-2018 NSUクラス II2017.07.18Becton Dickinson & Co.

BD recently notified customers in July 2017 regarding an increased rate of unresolved (UNR) and indeterminate (IND) results for the BD MAXTM Vaginal Panel, experienced by some customers. A non-reportable result may lead to repeat of the test and/or re-collection of a specimen.

終了
Z-0392-2018 NSUクラス II2017.07.18Becton Dickinson & Co.

BD recently notified customers in July 2017 regarding an increased rate of unresolved (UNR) and indeterminate (IND) results for the BD MAXTM Vaginal Panel, experienced by some customers. A non-reportable result may lead to repeat of the test and/or re-collection of a specimen.

終了
Z-0853-06 NSU

510(k)(市販前届出)

全 13 件
No.番号機器名申請者決定日種別概要
1K163652 ePlex InstrumentGenmark Diagnostics, Incorporated2017.06.09通常(Traditional) PDF
2K143178 FilmArray 2.0 SystemBiofire Diagnostics, LLC2015.01.30通常(Traditional) PDF
3K133849 VANTERA CLINICAL ANALYZERLiposcience2014.10.22特別(Special) PDF
4K141220 APPLIED BIOSYSTEMS 7500 FAST DX REAL-TIME PCR INSTRUMENT WITH SDS SOFTWAREThermo Fisher Scientific (Life Technologies Holdin2014.05.22特別(Special) PDF
5K133302 FLEXMAP 3DLuminex Corp.2014.01.10通常(Traditional)
6K121399 LUMINEX FLEXMAP 3D INSTRUMENT SYSTEM, LUMINEX XPONENT 4.0 SPI SOFTWARE, FLEXMAP 3D IVD CALIBRATION KIT, FLEXMAP 3D IVD PLuminex Corp.2013.01.09通常(Traditional)
7K110786 ESENSOR WARFARIN SENSITIVITY SALIVA TESTGenMark Diagnostics, Inc.2011.12.02通常(Traditional) PDF
8K093128 ILLUMINA BEADXPRESS SYSTEMIllumina, Inc.2010.04.28通常(Traditional)
9K082562 APPLIED BIOSYSTEMS 7500 FAST DXApplied Biosystems, Inc.2008.09.30通常(Traditional) PDF
10K080995 MODIFICATION TO AFFYMETRIX GENECHIP MICROARRAY INSTRUMENTATION SYSTEMAffymetrix, Inc.2008.07.30通常(Traditional)
11K073506 LUMINEX LX 100/200 INSTRUMENTLuminex Corp.2008.03.07通常(Traditional)
12K070597 VERIGENE SYSTEM, F2 NUCLEIC ACID TEST, F5 NUCLEIC ACID TEST, AND MTHFR NUCLEIC ACID TESTNanosphere, Inc.2007.10.11通常(Traditional) PDF
13DEN040012 AFFYMETRIX GENECHIP MICROARRAY INSTRUMENTATION SYSTEMAffymetrix, Inc.2004.12.23De Novo(Post-NSE)

出典の openFDA は各 510(k) の主要(primary)product code のみを収録しているため、副次コードを含む FDA 公式データベースの検索結果とは件数が異なる場合があります。 FDA 510(k) データベースで確認

PMA(市販前承認)

この product code の PMA 情報はありません。

不具合報告(MAUDE)トレンド

米国不具合報告検索で詳しく見る

出典: openFDA(U.S. FDA) のデータをそのまま掲載しています。内容の正確性・最新性は保証されません。FDA が本サイトの内容を承認・保証するものではありません。

報告の存在は、機器と事象の因果関係を意味しません。報告件数を機器間の不具合発生率の比較に用いることはできません。

各データセット(510(k)・PMA・MAUDE・回収・Warning Letter)の解説は 米国FDA情報の概要 を参照してください。

不具合報告データを読み込み中...

出典: openFDA(U.S. FDA) のデータをそのまま掲載しています。内容の正確性・最新性は保証されません。FDA が本サイトの内容を承認・保証するものではありません。

取得日: 2026.09.07

各データセット(510(k)・PMA・MAUDE・回収・Warning Letter)の解説は 米国FDA情報の概要 を参照してください。